Effects of leukocyte depletion on the quality of stored whole blood

被引:0
|
作者
Neumeister, B
Grauer, M
Koch, M
Hornlein, R
Dinkelmann, S
Bernhard, R
Haap, M
Northoff, H
机构
[1] Univ Klimikums Tubingen, Klin Anasthesiol & Transfus Med, Abt Transfus Med, Tubingen, Germany
[2] Univ Klinikums Tubingen, Klin Anasthesiol & Transfus Med, Blutbank, Tubingen, Germany
[3] Univ Klinikum Tubingen, Zentrallabor Med Klin, Tubingen, Germany
来源
ANAESTHESIST | 1997年 / 46卷 / 11期
关键词
autologous blood donations; whole blood; leukocyte depletion; storage quality;
D O I
10.1007/s001010050496
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: According to the German Guidelines for Hemotherapy, preoperative autologous blood donations can be stored and transfused as whole blood. In contrast to the storage of blood components, however, storage of whole blood results in deterioration of the biological quality due to contamination with leukocytes and platelets. In this study we examined the influence ai prestorage leukocyte depletion on the duality of Filtered whole blood donations during storage, Material and Methods: Whole blood was donated by healthy volunteers (n=14,500 mi, 70 mi CPDA-1) and was filtered using an integrated whole blood filter system (Leukotrap Al, Fa.Pall, Dreieich, Germany). The leukocyte-depleted whole blood units were then stored for up to 49 days, Several hematological and biochemical parameters indicative of the quality of blood donations were determined during storage. Results: Our data indicate a quality of leukocyte-depleted whole blood donations comparable to buffy-coat-free red blood cell units. Conclusions: The Leukotrap Al whole blood filter system is an interesting option for hospitals lacking the technical capacity to separate whole blood into components. The clinical suitability remains to he investigated by means of clinical studies.
引用
收藏
页码:979 / 982
页数:4
相关论文
共 50 条
  • [1] EFFECTS OF LEUKOCYTE DEPLETION ON THE FORMATION OF ANAPHYLATOXINS IN STORED WHOLE-BLOOD
    SCHLEUNING, M
    UTZ, H
    HEIM, M
    MEMPEL, W
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1992, 19 (05): : 242 - 244
  • [2] Effects of leukocyte depletion on the quality of stored whole blood [AUSWIRKUNGEN DER LEUKOZYTENDEPLETION AUF DIE LAGERUNGSQUALITAT VON VOLLBLUT]
    Neumeister B.
    Grauer M.
    Koch M.
    Hörnlein R.
    Dinkelmann S.
    Bernhard R.
    Northoff M.H.H.
    Der Anaesthesist, 1997, 46 (11) : 979 - 982
  • [3] PRESTORAGE LEUKOCYTE DEPLETION WITH IN-LINE FILTRATION OF WHOLE-BLOOD IN COMPARISON WITH BLOOD COMPONENT LEUKOCYTE DEPLETION
    RIGGERT, J
    SIMSON, G
    DITTMANN, J
    KOHLER, M
    VOX SANGUINIS, 1995, 69 (03) : 201 - 205
  • [4] Quality of Platelets in Stored Whole Blood
    van der Meer, Pieter F.
    Klei, Thomas R. L.
    de Korte, Dirk
    TRANSFUSION MEDICINE REVIEWS, 2020, 34 (04) : 234 - 241
  • [5] Effects of leukocyte depletion of blood transfusions on postoperative complications
    van de Watering, L
    PERFUSION-UK, 2001, 16 : 57 - 60
  • [6] Quality of whole blood as a result of storage and preparation (inline-leukocyte depletion). Evidence for autologous predeposit.
    von Bormann, B
    Wirtz, S
    Weiler, J
    von Bormann, C
    Trobisch, H
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2000, 35 (05): : 326 - 332
  • [7] Effects of insulin on platelet and leukocyte activity in whole blood
    Hu, H
    Hjemdahl, P
    Li, NL
    THROMBOSIS RESEARCH, 2002, 107 (05) : 209 - 215
  • [8] POSSIBILITY TO IMPROVE PRESERVATION OF WHOLE-BLOOD BY LEUKOCYTE-DEPLETION BEFORE STORAGE
    RIEDNER, C
    HEIM, MU
    MEMPEL, W
    WILMANNS, W
    VOX SANGUINIS, 1990, 59 (02) : 78 - 82
  • [9] Leukocyte depletion of whole blood and red cells from donors with hemoglobin sickle trait
    Williamson, LM
    Beard, M
    Seghatchian, J
    Cardigan, R
    Booker, W
    Heslip, J
    Bennett, J
    Smith, K
    Boralessa, H
    TRANSFUSION, 1999, 39 (10) : 108S - 108S
  • [10] Physiological quality assessment of stored whole blood by means of electrical measurements
    Ulgen, Y.
    Sezdi, M.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (07) : 653 - 660