Sub-pico-Newton shear-force feedback system in air and liquid for scanning probe microscopy

被引:2
作者
Giaccari, P [1 ]
Sqalli, O [1 ]
Limberger, HG [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Opt Appliquee, CH-1015 Lausanne, Switzerland
关键词
D O I
10.1063/1.1786335
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Scanning near-field optical microscopy requires a performant sensor to measure the tip-to-sample distance. In this article, we report on a shear force detection scheme for scanning near-field optical microscopy applications. It is based on an all fiber low-coherence interferometer. This setup makes possible the measurements of the tip oscillation amplitude of less than 50 pm both in air and aqueous environment with a precision of 160 fm/Hz(1/2), thus demonstrating the ability to perform topographic measurements both in air and in liquids with a resolution better than 1 nm in tip-sample distance. Stable feedback in air and fluids is obtained with tip-sample interaction forces below 1 pN. (C) 2004 American Institute of Physics.
引用
收藏
页码:3031 / 3033
页数:3
相关论文
共 10 条
[1]   COMBINED SHEAR FORCE AND NEAR-FIELD SCANNING OPTICAL MICROSCOPY [J].
BETZIG, E ;
FINN, PL ;
WEINER, JS .
APPLIED PHYSICS LETTERS, 1992, 60 (20) :2484-2486
[2]   Piezoelectrical shear-force distance control in near-field optical microscopy for biological applications [J].
Hollricher, O ;
Brunner, R ;
Marti, O .
ULTRAMICROSCOPY, 1998, 71 (1-4) :143-147
[3]   Interfacial shear force microscopy [J].
Karrai, K ;
Tiemann, I .
PHYSICAL REVIEW B, 2000, 62 (19) :13174-13181
[4]   Reduction of tip-sample interaction forces for scanning near-field optical microscopy in a liquid environment [J].
Lambelet, P ;
Pfeffer, M ;
Sayah, A ;
Marquis-Weible, F .
ULTRAMICROSCOPY, 1998, 71 (1-4) :117-121
[5]   Chemically etched fiber tips for near-field optical microscopy: a process for smoother tips [J].
Lambelet, P ;
Sayah, A ;
Pfeffer, M ;
Philipona, C ;
Marquis-Weible, F .
APPLIED OPTICS, 1998, 37 (31) :7289-7292
[6]   Shear-force detection based on an external cavity laser interferometer for a compact scanning near field optical microscope [J].
Pfeffer, M ;
Lambelet, P ;
Marquis-Weible, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (12) :4478-4482
[7]   OPTICAL STETHOSCOPY - IMAGE RECORDING WITH RESOLUTION LAMBDA/20 [J].
POHL, DW ;
DENK, W ;
LANZ, M .
APPLIED PHYSICS LETTERS, 1984, 44 (07) :651-653
[8]   Imaging soft samples in liquid with tuning fork based shear force microscopy [J].
Rensen, WHJ ;
van Hulst, NF ;
Kämmer, SB .
APPLIED PHYSICS LETTERS, 2000, 77 (10) :1557-1559
[9]   Tuning fork shear-force feedback [J].
Ruiter, AGT ;
van der Werf, KO ;
Veerman, JA ;
Garcia-Parajo, MF ;
Rensen, WHJ ;
van Hulst, NF .
ULTRAMICROSCOPY, 1998, 71 (1-4) :149-157
[10]  
Thomson WT, 1988, Theory of Vibration with Applications