Continuous-flow single-molecule CE with high detection efficiency

被引:38
作者
Schiro, Perry G. [1 ]
Kuyper, Christopher L. [1 ]
Chiu, Daniel T. [1 ]
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
关键词
confocal LIF; fluorescence correlation spectroscopy; microchip electrophoresis; single-molecule;
D O I
10.1002/elps.200600730
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the use of two-beam line-confocal detection geometry for measuring the total mobility of individual molecules undergoing continuous-flow CE separation. High-sensitivity single-molecule confocal detection is usually performed with a diffraction limited focal spot (similar to 500nm in diameter), which necessitates the use of nanometer-sized channels to ensure all molecules flow through the detection volume. To allow for the use of larger channels that are a few micrometers in width, we employed cylindrical optics to define a rectangular illumination area that is diffraction-limited (similar to 500 nm) in width, but a few micrometers in length to match the width of the microchannel. We present detailed studies that compare the performance of this line-confocal detection geometry with the more widely used point-confocal geometry. Overall, we found line-confocal detection to provide the highest combination of signal-to-background ratio and spatial detection efficiency when used with micrometer-sized channels. For example, in a 2 Pin wide channel we achieved a 94% overall detection efficiency for single Alexa488 dye molecules when a 2 mu m x 0.5 mu m illumination area was used, but only 34% detection efficiency with a 0.5 mu m diameter detection spot. To carry out continuous-flow CE, we used two-beam fluorescent cross-correlation spectroscopy where the transit time of each molecule is determined by cross-correlating the fluorescence registered by two spatially offset line-confocal detectors. We successfully separated single molecules of FITC, FITC-tagged glutamate, and FITC-tagged glycine.
引用
收藏
页码:2430 / 2438
页数:9
相关论文
共 45 条
[1]   Fabrication of topologically complex three-dimensional microfluidic systems in PDMS by rapid prototyping [J].
Anderson, JR ;
Chiu, DT ;
Jackman, RJ ;
Cherniavskaya, O ;
McDonald, JC ;
Wu, HK ;
Whitesides, SH ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3158-3164
[2]  
[Anonymous], 1990, CONFOCAL MICROSCOPY
[3]   DETECTING SINGLE MOLECULES IN LIQUIDS [J].
BARNES, MD ;
WHITTEN, WB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :A418-A423
[4]  
Born M, 2005, Principles of optics
[5]   Single-molecule identification of Coumarin-120 by time-resolved fluorescence detection: Comparison of one- and two-photon excitation in solution [J].
Brand, L ;
Eggeling, C ;
Zander, C ;
Drexhage, KH ;
Seidel, CAM .
JOURNAL OF PHYSICAL CHEMISTRY A, 1997, 101 (24) :4313-4321
[6]   Two beam cross correlation:: A method to characterize transport phenomena in micrometer-sized structures [J].
Brinkmeier, M ;
Dörre, K ;
Stephan, J ;
Eigen, M .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :609-616
[7]   Evaluation of two-beam fluorescence cross correlation spectroscopy for electrophoretic analysis of protein digests [J].
Brister, PC ;
Weston, KD .
ANALYST, 2006, 131 (02) :303-310
[8]   SINGLE-MOLECULE ELECTROPHORESIS [J].
CASTRO, A ;
SHERA, EB .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3181-3186
[9]   INTERACTION OF CAPILLARY ZONE ELECTROPHORESIS WITH A SHEATH FLOW CUVETTE DETECTOR [J].
CHENG, YF ;
WU, SL ;
CHEN, DY ;
DOVICHI, NJ .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :496-503
[10]   Diffusion coefficient measurements in microfluidic devices [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
TALANTA, 2002, 56 (02) :365-373