Cardiac allograft vasculopathy (CAV) is the leading cause of morbidity and mortality in heart transplantation (HT). We sought to investigate the role of coronary flow reserve (CFR) by contrast-enhanced transthoracic echocardiography (CE-TTE) in CAV diagnosis. CAV was defined as maximal intimal thickness (MIT) assessed by intravascular ultrasound (IVUS) >= 0.5 mm. CFR was assessed in the left anterior descending coronary artery in 22 HT recipients at 6 +/- 4 years post-HT. CAV was diagnosed in 10 patients (group A), 12 had normal coronaries (group B). The mean MIT was 0.7 +/- 0.1 mm (range 0.03-1.8). MIT was higher in group A (1.16 +/- 0.3 mm vs. 0.34 +/- 0.07 mm, p < 0.0001). CFR was 3.1 +/- 0.8 in all patients and lower in group A (2.5 +/- 0.6 vs. 3.7 +/- 0.3, p < 0.0001). CFR was inversely related with MIT (r = -0.774, p < 0.0001). A cut point of < 2.9, identified as optimal by receiver operating characteristics analysis was 100% specific and 80% sensitive (PPV = 100%, NPV = 89%, Accuracy = 91%). CFR assessment by CE-TTE is a novel noninvasive diagnostic tool in the detection of CAV defined as MIT >= 0.5 mm. CFR by CE-TTE may reduce the need for routine IVUS in HT.
引用
收藏
页码:1668 / 1676
页数:9
相关论文
共 27 条
  • [1] BILLINGHAM ME, 1992, J HEART LUNG TRANSPL, V11, pS38
  • [2] Reproducibility of serial intravascular ultrasound measurements in patients with angiographically silent coronary artery disease after heart transplantation
    Bocksch, W
    Wellnhofer, E
    Schartl, M
    Dreysse, S
    Klimek, W
    Franke, R
    Musci, M
    Hetzer, R
    Fleck, E
    [J]. CORONARY ARTERY DISEASE, 2000, 11 (07) : 555 - 562
  • [3] Immune and nonimmune predictors of cardiac allograft vasculopathy onset and severity: Multivariate risk factor analysis and role of immunosuppression
    Caforio, ALP
    Tona, F
    Fortina, AB
    Angelini, A
    Piaserico, S
    Gambino, A
    Feltrin, G
    Ramondo, A
    Valente, M
    Iliceto, S
    Thiene, G
    Gerosa, G
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2004, 4 (06) : 962 - 970
  • [4] Caforio ALP, 2000, CIRCULATION, V102, P222
  • [5] Validation of a new noninvasive, method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve - Comparison with intracoronary Doppler flow wire
    Caiati, C
    Montaldo, C
    Zedda, N
    Montisci, R
    Ruscazio, V
    Lai, G
    Cadeddu, J
    Meloni, L
    Iliceto, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (04) : 1193 - 1200
  • [6] New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler
    Caiati, C
    Montaldo, C
    Zedda, N
    Bina, A
    Iliceto, S
    [J]. CIRCULATION, 1999, 99 (06) : 771 - 778
  • [7] INFLUENCE OF INTIMAL THICKENING ON CORONARY BLOOD-FLOW RESPONSES IN ORTHOTOPIC HEART-TRANSPLANT RECIPIENTS - A COMBINED INTRAVASCULAR DOPPLER AND ULTRASOUND IMAGING STUDY
    CARACCIOLO, EA
    WOLFORD, TL
    UNDERWOOD, RD
    DONOHUE, TJ
    BACH, RG
    MILLER, LW
    KERN, MJ
    [J]. CIRCULATION, 1995, 92 (09) : 182 - 190
  • [8] ABNORMALITIES IN INTRAMYOCARDIAL ARTERIES DETECTED IN CARDIAC TRANSPLANT BIOPSY SPECIMENS AND LACK OF CORRELATION WITH ABNORMAL INTRACORONARY ULTRASOUND OR ENDOTHELIAL DYSFUNCTION IN LARGE EPICARDIAL CORONARY-ARTERIES
    CLAUSELL, N
    BUTANY, J
    MOLOSSI, S
    LONN, E
    GLADSTONE, P
    RABINOVITCH, M
    DALY, PA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (01) : 110 - 119
  • [9] Dandel M, 2001, CIRCULATION, V104, pI184
  • [10] Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients - Physiologic investigation for transplant arteriopathy (PITA study)
    Fearon, WF
    Nakamura, M
    Lee, DP
    Rezaee, M
    Vagelos, RH
    Hunt, SA
    Fitzgerald, PJ
    Yock, PG
    Yeung, AC
    [J]. CIRCULATION, 2003, 108 (13) : 1605 - 1610