A mitral annulus tracking approach for navigation of off-pump beating heart mitral valve repair

被引:11
作者
Li, Feng P. [1 ]
Rajchl, Martin [1 ]
Moore, John [1 ]
Peters, Terry M. [1 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, Imaging Lab, London, ON N6A 5B7, Canada
基金
加拿大健康研究院;
关键词
beating heart mitral valve repair; image guidance; ultrasound; mitral annulus tracking; real-time; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ULTRASOUND; GUIDANCE; SEGMENTATION; SURGERY; REGISTRATION; REGURGITATION; IMPLANTATION; FLUOROSCOPY; FUSION;
D O I
10.1118/1.4904022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and validate a real-time mitral valve annulus (MVA) tracking approach based on biplane transesophageal echocardiogram (TEE) data and magnetic tracking systems (MTS) to be used in minimally invasive off-pump beating heart mitral valve repair (MVR). Methods: The authors' guidance system consists of three major components: TEE, magnetic tracking system, and an image guidance software platform. TEE provides real-time intraoperative images to show the cardiac motion and intracardiac surgical tools. The magnetic tracking system tracks the TEE probe and the surgical tools. The software platform integrates the TEE image planes and the virtual model of the tools and the MVA model on the screen. The authors' MVA tracking approach, which aims to update the MVA model in near real-time, comprises of three steps: image based gating, predictive reinitialization, and registration based MVA tracking. The image based gating step uses a small patch centered at each MVA point in the TEE images to identify images at optimal cardiac phases for updating the position of the MVA. The predictive reinitialization step uses the position and orientation of the TEE probe provided by the magnetic tracking system to predict the position of the MVA points in the TEE images and uses them for the initialization of the registration component. The registration based MVA tracking step aims to locate the MVA points in the images selected by the image based gating component by performing image based registration. Results: The validation of the MVA tracking approach was performed in a phantom study and a retrospective study on porcine data. In the phantom study, controlled translations were applied to the phantom and the tracked MVA was compared to its "true" position estimated based on a magnetic sensor attached to the phantom. The MVA tracking accuracy was 1.29 +/- 0.58 mm when the translation distance is about 1 cm, and increased to 2.85 +/- 1.19 mm when the translation distance is about 3 cm. In the study on porcine data, the authors compared the tracked MVA to a manually segmented MVA. The overall accuracy is 2.37 +/- 1.67 mm for single plane images and 2.35 +/- 1.55 mm for biplane images. The interoperator variation in manual segmentation was 2.32 +/- 1.24 mm for single plane images and 1.73 +/- 1.18 mm for biplane images. The computational efficiency of the algorithm on a desktop computer with an Intel (R) Xeon (R) CPU @3.47 GHz and an NVIDIA GeForce 690 graphic card is such that the time required for registering four MVA points was about 60 ms. Conclusions: The authors developed a rapid MVA tracking algorithm for use in the guidance of off-pump beating heart transapical mitral valve repair. This approach uses 2D biplane TEE images and was tested on a dynamic heart phantom and interventional porcine image data. Results regarding the accuracy and efficiency of the authors' MVA tracking algorithm are promising, and fulfill the requirements for surgical navigation. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:456 / 468
页数:13
相关论文
共 50 条
  • [31] Transapical off-pump echo-guided mitral valve repair with neochordae implantation mid-term outcomes
    Gerosa, Gino
    Nadali, Matteo
    Longinotti, Lorenzo
    Ponzoni, Matteo
    Caraffa, Raphael
    Fiocco, Alessandro
    Pradegan, Nicola
    Besola, Laura
    D'Onofrio, Augusto
    Bizzotto, Eleonora
    Bellu, Roberto
    Gentian, Denas
    Colli, Andrea
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (01) : 131 - 140
  • [32] Transapical off-pump mitral valve repair with NeoChord™ implantation: An early single-center Portuguese experience
    Goncalves-Teixeira, Pedro
    Costa, Sara
    Martins, Daniel
    Neves, Paulo
    Ribeiro, Jose
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (12) : 933 - 941
  • [33] Transapical beating heart mitral valve repair with the NeoChord system: early outcomes of a single-center experience
    Wrobel, Krzysztof
    Kurnicka, Katarzyna
    Zygier, Marcin
    Zielinski, Dariusz
    Dyk, Wojciech
    Wojdyga, Ryszard
    Juraszynski, Zbigniew
    Pruszczyk, Piotr
    Biederman, Andrzej
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2019, 14 (02) : 320 - 325
  • [34] Echocardiographic Assessment of the Mitral Valve for Suitability of Repair: An Intraoperative Approach From a Mitral Center
    Mahmood, Feroze
    Sharkey, Aidan
    Maslow, Andrew
    Mufarrih, Syed Hamza
    Qureshi, Nada Qaisar
    Matyal, Robina
    Khabbaz, Kamal R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (07) : 2164 - 2176
  • [35] Minimally invasive off-pump valve-in-a-valve implantation: the atrial transcatheter approach for re-operative mitral valve replacement
    Kempfert, Jorg
    Blumenstein, Johannes M.
    Borger, Michael A.
    Linke, Axel
    Lehmann, Sven
    Pritzwald-Stegmann, Patrick
    Chu, Michael W. A.
    Schuler, Gerhard
    Falk, Volkmar
    Mohr, Friedrich Wilhelm
    Walther, Thomas
    EUROPEAN HEART JOURNAL, 2008, 29 (19) : 2382 - 2387
  • [36] Minimally invasive off-pump valve-in-a-ring implantation: the atrial transcatheter approach for re-operative mitral valve replacement after failed repair
    Kempfert, Joerg
    Blumenstein, Johannes
    Chu, Michael W. A.
    Pritzwald-Stegmann, Patrick
    Kobilke, Tobias
    Falk, Volkmar
    Mohr, Friedrich W.
    Walther, Thomas
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (06) : 965 - 969
  • [37] Porcelain aorta: a new indication for on-pump beating heart mitral valve replacement
    Yay, Kerem
    Hanedan, Muhammet Onur
    Basar, Veysel
    Tutun, Ufuk
    Altintas, Garip
    Cicekcioglu, Ferit
    Katircioglu, Salih Fehmi
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 20 (01): : 122 - 124
  • [38] Transapical off-pump mitral valve repair. First experience with the NeoChord system in Poland (report of two cases)
    Wrobel, Krzysztof
    Kurnicka, Katarzyna
    Zygier, Marcin
    Dyk, Wojciech
    Wojdyga, Ryszard
    Zielinski, Dariusz
    Jarzebska, Malgorzata
    Juraszynski, Zbigniew
    Lichodziejewska, Barbara
    Pruszczyk, Piotr
    Biederman, Andrzej
    Speziali, Giovanni
    Kasten, Uwe
    KARDIOLOGIA POLSKA, 2017, 75 (01) : 7 - 12
  • [39] Preoperative mitral valve annulus area size is an important factor in avoiding functional mitral stenosis after mitral valve repair
    Sasaki, Haruka
    Takaoka, Hiroyuki
    Yoshida, Kazuki
    Matsumoto, Moe
    Nishikawa, Yusei
    Noguchi, Yoshitada
    Aoki, Shuhei
    Suzuki, Katsuya
    Yashima, Satomi
    Kinoshita, Makiko
    Suzuki-Eguchi, Noriko
    Takanashi, Shuichiro
    Matsumiya, Goro
    Kobayashi, Yoshio
    JOURNAL OF ECHOCARDIOGRAPHY, 2024, : 123 - 132
  • [40] The potential of transapical beating-heart mitral valve repair with neo-chordae
    Kiefer, Philipp
    Seeburger, Joerg
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (01)