Simultaneous plasma and electric field diagnostics of microdischarge from hydrogen Balmer line shape

被引:14
|
作者
Spasojevic, Dj. [1 ]
Cvejic, M. [1 ]
Sisovic, N. M. [1 ]
Konjevic, N. [1 ]
机构
[1] Univ Belgrade, Fac Phys, Belgrade 11001, Serbia
关键词
argon; electron density; glow discharges; hydrogen; plasma density; plasma diagnostics; plasma sheaths; spectral line broadening; DISCHARGE; EMISSION;
D O I
10.1063/1.3449129
中图分类号
O59 [应用物理学];
学科分类号
摘要
Hydrogen Balmer beta line shape from a microhollow gas discharge in argon with traces of hydrogen is used for simultaneous diagnostics of plasma and cathode sheath parameters. Simple model of relevant processes responsible for line broadening is developed and results favorably compared with experiment at 500 mbar with the electron density 3.8x10(20) m(-3) and electric field strength of 127 kV/cm in the cathode sheath region. (C) 2010 American Institute of Physics. [doi:10.1063/1.3449129]
引用
收藏
页数:3
相关论文
共 24 条
  • [1] Comment on "Hydrogen Balmer beta: The separation between line peaks for plasma electron density diagnostics and self-absorption test"
    Gautam, Ghaneshwar
    Surmick, David M.
    Parigger, Christian G.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 160 : 19 - 21
  • [2] Hydrogen Balmer beta: The separation between line peaks for plasma electron density diagnostics and self-absorption test
    Ivkovic, Milivoje
    Konjevic, Nikola
    Pavlovic, Zoran
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 154 : 1 - 8
  • [3] Laser plasma diagnostics and self-absorption measurements of the Hβ Balmer series line
    Gautam, Ghaneshwar
    Parigger, Christian G.
    Surmick, David M.
    El Sherbini, Ashraf M.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2016, 170 : 189 - 193
  • [4] LINE SHAPE CALCULATIONS FOR PLASMA DIAGNOSTICS
    Gonzalez, M. A.
    Gigosos, M. A.
    4TH INTERNATIONAL CONGRESS ON COLD ATMOSPHERIC PRESSURE PLASMAS: SOURCES AND APPLICATIONS, PROCEEDINGS, 2009, : 24 - +
  • [5] Plasma diagnostics by laser spectroscopic electric field measurement
    Czarnetzki, U
    Luggenhölscher, D
    Kadetov, VA
    Döbele, HF
    PURE AND APPLIED CHEMISTRY, 2005, 77 (02) : 345 - 358
  • [6] Smooth line merging into the continuum and Stark broadening of deuterium Balmer lines for plasma diagnostics
    Koubiti, M
    Loch, S
    Capes, H
    Godbert-Mouret, L
    Marandet, Y
    Meigs, A
    Stamm, R
    Summers, H
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2003, 81 (1-4) : 265 - 273
  • [7] Atomic-hydrogen Balmer α line's abnormal broadening of argon and hydrogen plasma in hollow cathode
    Luan Bo-Han
    Qiao Zeng-Xi
    Liu Peng
    Zhao Wei
    E Peng
    Yu Da-Ren
    ACTA PHYSICA SINICA, 2012, 61 (01)
  • [8] Characteristics of saturation spectroscopy at the Balmer-α line of atomic hydrogen in a linear magnetized plasma source
    Asakawa, R.
    Goto, M.
    Sadeghi, N.
    Sasaki, K.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [9] Spectral line-shape calculations for multielectron ions in hot plasmas submitted to a strong oscillating electric field
    Peyrusse, O.
    PHYSICAL REVIEW A, 2009, 79 (01):
  • [10] Electron density calculation based on Stark broadening of D Balmer line from detached plasma in EAST tungsten divertor
    Xu, Feng
    Ding, Fang
    Chen, Xiahua
    Wang, Liang
    Xu, Jichan
    Hu, Zhenhua
    Mao, Hongmin
    Luo, Guangnan
    Yang, Zhongshi
    Chen, Jingbo
    Li, Kedong
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (10)