Derivation of Indices of Left Ventricular Contractility in the Setting of Continuous-Flow Left Ventricular Assist Device Support

被引:4
|
作者
Gupta, Sunil [1 ,2 ]
Muthiah, Kavitha [1 ,2 ,3 ]
Woldendorp, Kei [1 ,2 ]
Robson, Desiree [1 ]
Jansz, Paul [1 ]
Hayward, Christopher S. [1 ,2 ,3 ]
机构
[1] St Vincents Hosp, Heart Failure & Transplant Unit, Sydney, NSW 2010, Australia
[2] Univ New S Wales, Fac Med, Sydney, NSW, Australia
[3] Victor Chang Cardiac Res Inst, Sydney, NSW, Australia
关键词
Contractility; Left ventricular assist device; Continuous flow; Heart failure; RECOVERY; BRIDGE;
D O I
10.1111/aor.12292
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is important to accurately monitor residual cardiac function in patients under long-term continuous-flow left ventricular assist device (cfLVAD) support. Two new measures of left ventricular (LV) chamber contractility in the cfLVAD-unloaded ventricle include I-Q, a regression coefficient between maximum flow acceleration and flow pulsatility at different pump speeds; and K, a logarithmic relationship between volumes moved in systole and diastole. We sought to optimize these indices. We also propose RIQ, a ratio between maximum flow acceleration and flow pulsatility at baseline pump speed, as an alternative to I-Q. Eleven patients (mean age 49 +/- 11 years) were studied. The K index was derived at baseline pump speed by defining systolic and diastolic onset as time points at which maximum and minimum volumes move through the pump. I-Q across the full range of pump speeds was markedly different between patients. It was unreliable in three patients with underlying atrial fibrillation (coefficient of determination R-2 range: 0.38-0.74) and also when calculated without pump speed manipulation (R-2 range: 0.01-0.74). The K index was within physiological ranges, but poorly correlated to both I-Q (P=0.42) and RIQ (P=0.92). In four patients there was excellent correspondence between RIQ and I-Q, while four other patients showed a poor relationship between these indices. As RIQ does not require pump speed changes, it may be a more clinically appropriate measure. Further studies are required to determine the validity of these indices.
引用
收藏
页码:1029 / 1034
页数:6
相关论文
共 50 条
  • [1] Impact of continuous-flow left ventricular assist device support on right ventricular function
    Morgan, Jeffrey A.
    Paone, Gaetano
    Nemeh, Hassan W.
    Murthy, Raghav
    Williams, Celeste T.
    Lanfear, David E.
    Tita, Cristina
    Brewer, Robert J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04) : 398 - 403
  • [2] Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist Device
    Pagani, Francis D.
    Miller, Leslie W.
    Russell, Stuart D.
    Aaronson, Keith D.
    John, Ranjit
    Boyle, Andrew J.
    Conte, John V.
    Bogaev, Roberta C.
    MacGillivray, Thomas E.
    Naka, Yoshifumi
    Mancini, Donna
    Massey, H. Todd
    Chen, Leway
    Klodell, Charles T.
    Aranda, Juan M.
    Moazami, Nader
    Ewald, Gregory A.
    Farrar, David J.
    Frazier, O. Howard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) : 312 - 321
  • [3] Continuous-Flow Left Ventricular Assist Device and the Right Ventricle
    Puhlman, Mark
    AACN ADVANCED CRITICAL CARE, 2012, 23 (01) : 86 - 90
  • [4] Left Ventricular Recovery with Explantation of Continuous-Flow Left Ventricular Assist Device after 5 Years of Support
    Critsinelis, Andre
    Kurihara, Chitaru
    Kawabori, Masashi
    Sugiura, Tadahisa
    Civitello, Andrew B.
    Morgan, Jeffrey A.
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 27 (03) : 211 - 214
  • [5] Tolerance of Sustained Ventricular Fibrillation During Continuous-Flow Left Ventricular Assist Device Support
    Baldwin, Andrew C. W.
    Gemmato, Courtney J.
    Sandoval, Elena
    Cohn, William E.
    Morgan, Jeffrey A.
    Frazier, O. H.
    TEXAS HEART INSTITUTE JOURNAL, 2017, 44 (05): : 357 - 360
  • [6] Late-onset right ventricular dysfunction after mechanical support by a continuous-flow left ventricular assist device
    Kapelios, Chris J.
    Charitos, Christos
    Kaldara, Elisabeth
    Malliaras, Konstantinos
    Nana, Ernmeleia
    Pantsios, Christos
    Repasos, Evangelos
    Tsamatsoulis, Michael.
    Toumanidis, Savvas
    Nanas, John N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) : 1604 - 1610
  • [7] Long-Term Continuous-Flow Left Ventricular Assist Device Support After Left Ventricular Outflow Tract Closure
    Kurihara, Chitaru
    Cohn, William E.
    Kawabori, Masashi
    Sugiura, Tadahisa
    Civitello, Andrew B.
    Morgan, Jeffrey A.
    ASAIO JOURNAL, 2019, 65 (06) : 558 - 564
  • [8] Gender differences in the risk of stroke during support with continuous-flow left ventricular assist device
    Morris, Alanna A.
    Pekarek, Ann
    Wittersheim, Kris
    Cole, Robert T.
    Gupta, Divya
    Duc Nguyen
    Laskar, S. Raja
    Butler, Javed
    Smith, Andrew
    Vega, J. David
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) : 1570 - 1577
  • [9] Twelve Hours of Sustained Ventricular Fibrillation Supported by a Continuous-Flow Left Ventricular Assist Device
    Sims, Daniel B.
    Rosner, Gregg
    Uriel, Nir
    Gonzalez-Costello, Jose
    Ehlert, Frederick A.
    Jorde, Ulrich P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (05): : e144 - e148
  • [10] Coronary Artery Remodeling and Fibrosis With Continuous-Flow Left Ventricular Assist Device Support
    Ambardekar, Amrut V.
    Weiser-Evans, Mary C. M.
    Li, Marcella
    Purohit, Suneet N.
    Aftab, Muhammad
    Reece, T. Brett
    Moulton, Karen S.
    CIRCULATION-HEART FAILURE, 2018, 11 (05) : e004491