Monitoring bispectral index of the EEG and management of hypertension during laparoscopic surgery.

被引:0
|
作者
Mavoungou, P
Billard, V
Moussaud, R
Potiron, L
机构
[1] Clin Mutualiste, Dept Anesthesiol, F-44100 Nantes, France
[2] Inst Gustave Roussy, Dept Anesthesiol, F-94805 Villejuif, France
[3] Clin Mutualiste, Serv Chirurg Gen, F-44100 Nantes, France
来源
关键词
laparoscopy; bispectral index; arterial hypertension;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Assessment of the usefulness of Bispectral Index of the EEG (BIS(TM)) for the management of hypertension during laparoscopic surgery. Study design: Preliminary, non-randomized study. Patients: 15 patients undergoing laparoscopic surgery. Methods: Anaesthesia by TCl of propofol and boluses of fentanyl in order to maintain fentanyl effect site concentration above 2 ng.mL(-1) according to Scott kinetics model. Mean arterial pressure (MAP), heart rate (HR) and BIS(TM) were recorded. BIS(TM) values between 40 and 60 and MAP between 80 to 120% of preinduction values were maintained using a Gurman like decision matrix. Results: MAP rose significantly after insufflation while variations of HR and BIS(TM) were not significant. Discussion: During laparoscopy, factors other than pain can be responsible for hypertension. Nevertheless in clinical practice, inadequate anaesthesia should be ruled out before considering other mechanisms for hypertension. In this study, hypnosis remained adequate with a BIS(TM) under 60, and analgesia was considered sufficient as demonstrated by a good stability of the BIS(TM) despite nociceptive stimuli. This suggests that more specific haemodynamic factors were responsible for the observed rise in arterial pressure. Conclusion: Associating BIS(TM) monitoring and MAP in a modified Gurman decision matrix may allow more judicious therapeutic choices for hypertension during laparoscopic surgery. (C) 2000 Editions scientifiques et medicales Elsevier SAS.
引用
收藏
页码:582 / 587
页数:6
相关论文
共 50 条
  • [41] Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol
    Ibrahim, AE
    Taraday, JK
    Kharasch, ED
    ANESTHESIOLOGY, 2001, 95 (05) : 1151 - 1159
  • [42] Interference of electromagnetic operating systems in otorhinolaryngology surgery with bispectral index monitoring
    Hemmerling, TM
    Desrosiers, M
    ANESTHESIA AND ANALGESIA, 2003, 96 (06): : 1698 - 1699
  • [43] Bispectral Index Monitoring to Facilitate Early Extubation Following Cardiovascular Surgery
    Anderson, Jennifer
    Henry, Linda
    Hunt, Sharon
    Ad, Niv
    CLINICAL NURSE SPECIALIST, 2010, 24 (03) : 140 - 148
  • [44] Bispectral index monitoring during dissociative pseudo-seizure
    Sartorius, Alexander
    Schmahl, Christian
    WORLD JOURNAL OF BIOLOGICAL PSYCHIATRY, 2009, 10 (04): : 603 - 605
  • [45] The Effect of Bispectral Index Monitoring during Induction of Anesthesia on the Amount of Propofol Consumtion in Patients Candidates for Surgery
    Shahram, Borjian Boroojeny
    Hojjat, Seyedeh Maryam
    JOURNAL OF CONTEMPORARY MEDICAL SCIENCES, 2021, 7 (04): : 256 - 260
  • [46] The Bispectral Index: A guide to the depth of anesthesia during spine surgery
    Urban, MK
    Urquhart, B
    ANESTHESIOLOGY, 2000, 93 (3A) : U147 - U147
  • [47] BRAIN MONITORING, BISPECTRAL INDEX, EEG, HYPOTHERMIA: OUTCOMES PREDICTION AND OPTIMAL FAMILY CARE
    Bridge, Barbara
    Arbour, Richard
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 128 - 128
  • [48] The effect of ketamine on EEG-bispectral index (BIS) during propofol sedation
    Avramov, MN
    Badrinath, S
    Shadrick, M
    Ivankovich, AD
    ANESTHESIOLOGY, 1997, 87 (03) : A501 - A501
  • [49] Comparative evaluation of the cerebral state index™ and bispectral index™ monitoring during propofol-remifentanil anesthesia for open heart surgery
    Shahbazi, Shahrbanoo
    Zand, Farid
    Saem, Jalal
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2007, 23 (04) : 505 - 509
  • [50] Interest of the bispectral index monitoring (BIS) in anesthetic management of interventional bronchoscopy
    Gouvitsos, F
    Eon, B
    Mak, MA
    Auffray, JP
    Gouin, F
    ANESTHESIOLOGY, 1998, 89 (3A) : U819 - U819