Extending Semiautomatic Ventilation Defect Analysis for Hyperpolarized 129Xe Ventilation MRI

被引:74
作者
He, Mu [1 ]
Kaushik, S. Sivaram [1 ,2 ]
Robertson, Scott H. [1 ,3 ]
Freeman, Matthew S. [1 ,3 ]
Virgincar, Rohan S. [1 ,2 ]
McAdams, H. Page [4 ]
Driehuys, Bastiaan [1 ,2 ,3 ,5 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27708 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[3] Duke Univ, Med Phys Grad Program, Durham, NC USA
[4] Duke Univ, Med Ctr, Dept Cardiothorac Imaging, Durham, NC USA
[5] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
Hyperpolarized Xe-129 MRI; ventilation defect analysis; lung segmentation; image registration; HEALTHY-VOLUNTEERS; HE-3; LUNGS;
D O I
10.1016/j.acra.2014.07.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Clinical deployment of hyperpolarized Xe-129 magnetic resonance imaging requires accurate quantification and visualization of the ventilation defect percentage (VDP). Here, we improve the robustness of our previous semiautomated analysis-method to reduce operator dependence, correct for B-1 inhomogeneity and vascular structures, and extend the analysis to display multiple intensity clusters. Materials and Methods: Two segmentation methods were compared-a seeded region-growing method, previously validated by expert reader scoring, and a new linear-binning method that corrects the effects of bias field and vascular structures. The new method removes nearly all operator interventions by rescaling the Xe-129 magnetic resonance images to the 99th percentile of the cumulative distribution and applying fixed thresholds to classify Xe-129 voxels into four clusters: defect, low, medium, and high intensity. The methods were applied to 24 subjects including patients with chronic obstructive pulmonary disease (n = 8), age-matched controls (n = 8), and healthy normal subjects (n = 8). Results: Linear-binning enabled a faster and more reproducible workflow and permitted analysis of an additional 0.25 +/- 0.18 L of lung volume by accounting for vasculature. Like region-growing, linear-binning VDP correlated strongly with reader scoring (R-2 = 0.93, P < .0001), but with less systematic bias. Moreover, linear-binning maps clearly depict regions of low and high intensity that may prove useful for phenotyping subjects with chronic obstructive pulmonary disease. Conclusions: Corrected linear-binning provides a robust means to quantify Xe-129 ventilation images yielding VDP values that are indistinguishable from expert reader scores, while exploiting the entire dynamic range to depict multiple image clusters.
引用
收藏
页码:1530 / 1541
页数:12
相关论文
共 22 条
[1]   Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects [J].
Arnold, JB ;
Liow, JS ;
Schaper, KA ;
Stern, JJ ;
Sled, JG ;
Shattuck, DW ;
Worth, AJ ;
Cohen, MS ;
Leahy, RM ;
Mazziotta, JC ;
Rottenberg, DA .
NEUROIMAGE, 2001, 13 (05) :931-943
[2]   Intensity non-uniformity correction in MRI: Existing methods and their validation [J].
Belaroussi, B ;
Milles, J ;
Carme, S ;
Zhu, YM ;
Benoit-Cattin, H .
MEDICAL IMAGE ANALYSIS, 2006, 10 (02) :234-246
[3]   Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans [J].
Cleveland, Zackary I. ;
Cofer, Gary P. ;
Metz, Gregory ;
Beaver, Denise ;
Nouls, John ;
Kaushik, S. Sivaram ;
Kraft, Monica ;
Wolber, Jan ;
Kelly, Kevin T. ;
McAdams, H. Page ;
Driehuys, Bastiaan .
PLOS ONE, 2010, 5 (08)
[4]   High-volume production of laser-polarized Xe-129 [J].
Driehuys, B ;
Cates, GD ;
Miron, E ;
Sauer, K ;
Walter, DK ;
Happer, W .
APPLIED PHYSICS LETTERS, 1996, 69 (12) :1668-1670
[5]   Model-based quantitation of 3-D magnetic resonance angiographic images [J].
Frangi, AF ;
Niessen, WJ ;
Hoogeveen, RM ;
van Walsum, T ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :946-956
[6]   Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging [J].
Kaushik, S. Sivaram ;
Freeman, Matthew S. ;
Cleveland, Zackary I. ;
Davies, John ;
Stiles, Jane ;
Virgincar, Rohan S. ;
Robertson, Scott H. ;
He, Mu ;
Kelly, Kevin T. ;
Foster, W. Michael ;
McAdams, H. Page ;
Driehuys, Bastiaan .
JOURNAL OF APPLIED PHYSIOLOGY, 2013, 115 (06) :850-860
[7]   Hyperpolarized 3He and 129Xe MR Imaging in Healthy Volunteers and Patients with Chronic Obstructive Pulmonary Disease [J].
Kirby, Miranda ;
Svenningsen, Sarah ;
Owrangi, Amir ;
Wheatley, Andrew ;
Farag, Adam ;
Ouriadov, Alexei ;
Santyr, Giles E. ;
Etemad-Rezai, Roya ;
Coxson, Harvey O. ;
McCormack, David G. ;
Parraga, Grace .
RADIOLOGY, 2012, 265 (02) :600-610
[8]   Hyperpolarized 3He Magnetic Resonance Functional Imaging Semiautomated Segmentation [J].
Kirby, Miranda ;
Heydarian, Mohammadreza ;
Svenningsen, Sarah ;
Wheatley, Andrew ;
McCormack, David G. ;
Etemad-Rezai, Roya ;
Parraga, Grace .
ACADEMIC RADIOLOGY, 2012, 19 (02) :141-152
[9]  
Kramer D., 2010, PHYS TODAY, V63, P6
[10]   Quantitative Analysis of Hyperpolarized 3He Ventilation Changes in Mice Challenged With Methacholine [J].
Mistry, Nilesh N. ;
Thomas, Abraham ;
Kaushik, S. Sivaram ;
Johnson, G. Allan ;
Driehuys, Bastiaan .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :658-666