PURPOSE: To evaluate how well partial coherence interferometry (PCI) (IOLMaster) and optical low-coherence reflectometry (OLCR) (Lenstar LS 900) predict postoperative refractions using only the formulas that come preinstalled on the machines. SETTING: Private practice, Saint Joseph, Michigan, USA. DESIGN: Retrospective consecutive case series. METHODS: Eyes were measured with 2 biometers before cataract surgery. Six formulas were ranked by machine. Formulas were also ranked for extremely long and short eyes by averaging the ranks of 6 statistics (mean error, mean absolute error, standard deviation [SD], maximum error, and percentage of eyes within +/- 0.5 diopter [D] and +/- 1.0 D of prediction). RESULTS: Formulas were ranked by the SD of the prediction errors. The OLCR device outperformed the PCI device using the preinstalled formulas. The Olsen formula performed the best (0.378) but was preinstalled on the OLCR device only. Other formulas had the following SDs (OLCR device first, PCI device second): Haigis (0.393, 0.401), Holladay 1 (0.408, 0.414), Hoffer Q (0.428, 0.432), SRK/T (0.433, 0.440), and SRK II(0.623, 0.633). Rankings for long eye were (first to last) were Olsen, Haigis, SRK/T, Hoffer Q, and Holladay 1. Rankings for short eyes were Olsen, Haigis, Holladay 1, SRK/T, and Hoffer Q. CONCLUSIONS: The OLCR device outperformed the PCI device using the Olsen formula. The Olsen formula also ranked first for short eyes and long eyes. Other formulas performed about the same on both machines. The SRK II formula should be avoided. (c) 2016 ASCRS and ESCRS
引用
收藏
页码:358 / 362
页数:5
相关论文
共 15 条
  • [1] Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry
    Aristodemou, Petros
    Cartwright, Nathaniel E. Knox
    Sparrow, John M.
    Johnston, Robert L.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) : 63 - 71
  • [2] Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    Haigis, W
    Lege, B
    Miller, N
    Schneider, B
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) : 765 - 773
  • [3] Matrix-optical Representation of Currently Used Intraocular Lens Power Formulas
    Haigis, Wolfgang
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (02) : 229 - 234
  • [4] Hoffer KJ, 2007, J CATARACT REFR SURG, V33, P2, DOI 10.1016/j.jcrs.2006.08.054
  • [5] Errors in self-programming the Hoffer Q formula
    Hoffer, K. J.
    [J]. EYE, 2007, 21 (03) : 429 - 429
  • [6] Protocols for Studies of Intraocular Lens Formula Accuracy
    Hoffer, Kenneth J.
    Aramberri, Jaime
    Haigis, Wolfgang
    Olsen, Thomas
    Savini, Giacomo
    Shammas, H. John
    Bentow, Stanley
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) : 403 - 405
  • [7] HOFFER KJ, 1994, J CATARACT REFR SURG, V20, P677
  • [9] A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS
    HOLLADAY, JT
    PRAGER, TC
    CHANDLER, TY
    MUSGROVE, KH
    LEWIS, JW
    RUIZ, RS
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) : 17 - 24
  • [10] Olsen T., 2014, US patent, Patent No. [8,657,445, 8657445]