Comparison of two extraction methods independently developed on two conceptually different automated supercritical fluid extraction systems for the determination of polychlorinated biphenyls in sediments

被引:14
作者
Nilsson, T
Björklund, E
Bowadt, S
机构
[1] Univ Lund, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Commiss European Communities, Res Directorate Gen, B-1049 Brussels, Belgium
关键词
extraction methods; supercritical fluid extraction; sediments; environmental analysis; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(00)00630-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two extraction methods that independently have been developed on conceptually different automated supercritical fluid extraction systems, ISCO SFX 3560 (syringe pump and liquid trapping) and Hewlett-Packard 7680T SFE (reciprocating pump and solid-phase trapping), were compared for the extraction of polychlorinated biphenyls from two Swedish sediments. The results demonstrated that the high-temperature ISCO method in some cases yields a more exhaustive extraction, but also less clean extracts due to co-extraction of unwanted matrix components which are all present in the trapping solvent. The medium-temperature Hewlett-Packard method may sometimes cause problems with quantitative recoveries, but on the other hand it yields very clean extracts due to the extra selectivity resulting from collection on a solid-phase trap. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:195 / 199
页数:5
相关论文
共 11 条
[1]   SUPERCRITICAL FLUID EXTRACTION FOR THE RAPID-DETERMINATION OF POLYCHLORINATED DIBENZO-PARA-DIOXINS AND DIBENZOFURANS IN MUNICIPAL INCINERATOR FLY-ASH [J].
ALEXANDROU, N ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2770-2776
[2]   Determining PCB sorption desorption behavior on sediments using selective supercritical fluid ertraction.: 1.: Desorption from historically contaminated samples [J].
Björklund, E ;
Bowadt, S ;
Mathiasson, L ;
Hawthorne, SB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (13) :2193-2203
[3]   SUPERCRITICAL-FLUID EXTRACTION IN ENVIRONMENTAL-ANALYSIS [J].
BOWADT, S ;
HAWTHORNE, SB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :549-571
[4]  
Bowadt S., 1993, Journal of Trace and Microprobe Techniques, V11, P117
[5]   ANALYSIS OF PCBS IN SULFUR-CONTAINING SEDIMENTS BY OFF-LINE SUPERCRITICAL-FLUID EXTRACTION AND HRGC-ECD [J].
BOWADT, S ;
JOHANSSON, B .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :667-673
[6]   SOLID-PHASE TRAPPING OF POLYCHLORINATED-BIPHENYLS IN SUPERCRITICAL-FLUID EXTRACTION [J].
BOWADT, S ;
JOHANSSON, B ;
PELUSIO, F ;
LARSEN, BR ;
ROVIDA, C .
JOURNAL OF CHROMATOGRAPHY A, 1994, 662 (02) :424-433
[7]  
EPA (Environmental Protection Agency), 1996, TEST METH EV SOL WAS
[8]  
HAWTHORNE S B, 1990, Analytical Chemistry, V62, P633
[9]  
LARSSON P, COMMUNICATION
[10]   Evaluation of different solid-phase traps for automated collection and clean-up in the analysis of multiple pesticides in fruits and vegetables after supercritical fluid extraction [J].
Lehotay, SJ ;
ValverdeGarcia, A .
JOURNAL OF CHROMATOGRAPHY A, 1997, 765 (01) :69-84