Evaluation of Initial Stress Distribution and Displacement Pattern of Craniofacial Structures with 3 Different Rapid Maxillary Expansion Appliance Models: A 3-dimensional Finite Element Analysis

被引:2
|
作者
Sucu, Merve [1 ]
Yilmaz, Berna [2 ]
Ramoglu, Sabri Ilhan [3 ]
机构
[1] Orthodontics, Istanbul, Turkey
[2] Bezmialem Vakif Univ, Fac Dent, Dept Orthodont, Istanbul, Turkey
[3] Altinbas Univ, Fac Dent, Dept Orthodont, Istanbul, Turkey
关键词
Finite Element Method; rapid maxillary expansion; transverse maxillary deficiency; DENTAL CHANGES; SKELETAL;
D O I
10.5152/TurkJOrthod.2021.20006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study aimed to describe the displacement of anatomical structures and the stress distributions caused by the Hyrax, fan-type, and double-hinged expansion screws via the 3-dimensional (3D) finite element method (FEM). Methods: The 3D FEM was based on the computed tomography data of a 12-year-old patient with a constricted maxilla. The Hyrax model included 1,800,981 tetrahedral elements with 2,758,217 nodes. The fan-type model included 1,787,558 tetrahedral elements with 2,737,358 nodes. The double-hinged model included 1,777,080 tetrahedral elements with 2,722,771 nodes. The von Mises stress distributions after 0.2 mm of expansion and displacement patterns after 5 mm of expansion were evaluated. Results: The highest stress accumulation was observed in the sutura zygomatico maxillaris area with all 3 appliances. An increase in stress was noted at the pterygomaxillary fissure, the medial and lateral pterygoid process of the sphenoid bone, and the nasal areas. The wedge-shaped skeletal opening was observed with all 3 appliances. In the transverse plane, maximum posterior expansion was achieved with the Hyrax appliance, whereas the maximum anterior expansion was observed with the double-hinged appliance. The maxilla moved inferiorly and anteriorly with all the 3 appliances. The greatest inferior displacement of the maxilla was recorded with the Hyrax appliance, whereas anterior maxillary displacement was the greatest with the double-hinged appliance. Conclusion: All the appliances showed similar stress distributions. The use of double-hinged screw caused a slight anterior displacement of point A. The fan-type and double-hinged appliances were shown to be more effective on anterior maxillary constriction, whereas the Hyrax appliance might be chosen for resolving maxillary posterior constriction.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 22 条
  • [21] Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
    Shinya, Akikazu
    Ballo, Ahmed M.
    Lassila, Lippo V. J.
    Shinya, Akiyoshi
    Narhi, Timo O.
    Vallittu, Pekka K.
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 : 133 - 140
  • [22] A Comparative Evaluation of Effect of Different Ferrule Heights on Stress Distribution in Endodontically Treated Teeth Restored with Zirconia Post and Core System using 3D-Finite Element Analysis
    Gatkal, Vidya Satish
    Jankar, Ajit
    Joteppa, Varsha Vaijnath
    Zafar, Asim
    Nakade, Prashant
    Wadhwani, Madhuri
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (12) : ZC22 - ZC28