Exposure of personnel to sevoflurane during paediatric anaesthesia: influence of professional role and anaesthetic procedure

被引:16
作者
Gentili, A
Accorsi, A
Pigna, A
Bachiocco, V
Domenichini, I
Baroncini, S
Violante, ES
机构
[1] S Orsola M Malpighi Hosp, Dept Paediat Anaesthesia & Intens Care, I-40054 Bologna, Italy
[2] S Orsola M Malpighi Hosp, Occupat Med Serv, I-40054 Bologna, Italy
[3] Univ Bologna, Safety Hyg & Occupat Med Serv, Bologna, Italy
[4] Univ Bologna, Occupat Hlth Unit, Bologna, Italy
关键词
airway management; tracheal tube; laryngeal mask; bronchoscope; anaesthesia; paediatric; anaesthetics exposure; measurement; anaesthetics; inhalation; sevoflurane; operating room; personnel; techniques;
D O I
10.1017/S0265021504008099
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: This study was performed to determine the individual exposure of paediatric operating theatre personnel to sevoflurane and to evaluate the impact of inhalation induction and various airway approaches on exposure to airborne sevoflurane. Methods: Mean individual environmental (workplace air) exposure to sevoflurane and a biomarker of exposure (urinary sevoflurane) were monitored in 36 subjects (10 anaesthetists, 10 surgeons, 12 nurses and 4 auxiliary personnel) working in two paediatric operating rooms. Results: Environmental and urinary values were significantly greater in anaesthetists compared with other groups, with median values of 0.65 ppm (interquartile range 1.36; 95th percentile 4.36) for breathing zone sevoflurane and 2.1 mug L-1 urine (interquartile range 2.6; 95th percentile 7.6) for urinary sevoflurane. Anaesthetists exceeded the 2 ppm maximum allowed environmental concentration recommended by the National Institute for Occupational Safety and Health in 4 of 22 cases (18.1%). A positive correlation was found between the number of patients undergoing inhalational induction each day and mean values of breathing zone and urinary sevoflurane. An increase in the number of daily laryngeal mask insertions, or the use of rigid bronchoscopy, are statistically related to higher environmental and urinary values (P < 0.01 and <0.00001 for breathing zone sevoflurane, P < 0.05 and <0.01 for urinary sevoflurane, respectively). Conclusions: Anaesthesia with sevoflurane can pose a hazard of chronic exposure with anaesthetists having the highest risk. Endotracheal intubation offers considerable protection against exposure. Routine anaesthesia using a standard facemask, a laryngeal mask or rigid bronchoscopy are risk factors for increased anaesthetic exposure.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 34 条
[1]   Proposal for single and mixture biological exposure limits for sevoflurane and nitrous oxide at low occupational exposure levels [J].
Accorsi, A ;
Valenti, S ;
Barbieri, A ;
Raffi, GB ;
Violante, FS .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2003, 76 (02) :129-136
[2]   Biomonitoring of exposure to nitrous oxide, sevoflurane, isoflurane and halothane by automated GC/MS headspace urinalysis [J].
Accorsi, A ;
Barbieri, A ;
Raffi, GB ;
Violante, FS .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2001, 74 (08) :541-548
[3]  
ACCORSI A, 2003, IN PRESS TOXICOL IND
[4]   Risk of spontaneous abortion in women occupationally exposed to anaesthetic gases: a meta-analysis [J].
Boivin, JF .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 54 (08) :541-548
[5]   HEALTH EXPERIENCES OF OPERATING-ROOM PERSONNEL [J].
BRODSKY, JB ;
COHEN, EN .
ANESTHESIOLOGY, 1985, 63 (04) :461-463
[6]  
Byhahn C, 2000, Anaesthesiol Reanim, V25, P12
[7]   Surgeon's occupational exposure to nitrous oxide and sevoflurane during pediatric surgery [J].
Byhahn, C ;
Heller, K ;
Lischke, V ;
Westphal, K .
WORLD JOURNAL OF SURGERY, 2001, 25 (09) :1109-1112
[8]  
CALDWELL CB, 2002, PEDIAT ANESTHESIA, P217
[9]   OCCUPATIONAL EXPOSURE TO ANESTHETICS IN 20 HOSPITALS [J].
DAVENPORT, HT ;
HALSEY, MJ ;
WARDLEYSMITH, B ;
BATEMAN, PE .
ANAESTHESIA, 1980, 35 (04) :354-359
[10]  
*DHEW, 1977, DHEW PUB