Optimised GMP-compliant production of [18F]DPA-714 on the Trasis AllinOne module

被引:11
作者
Cybulska, Klaudia A. [1 ,2 ]
Bloemers, Vera [1 ]
Perk, Lars R. [1 ]
Laverman, Peter [2 ]
机构
[1] Radboud Translat Med BV, Geert Grootepl 21, NL-6525 EZ Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Radiol & Nucl Med, Geert Grootepl 10, NL-6525 GA Nijmegen, Netherlands
关键词
F-18]DPA-714; TSPO; PBR; PET; Fluorine-18; Radiochemistry; Radiopharmacy; GMP; Trasis AllinOne; Neuroinflammation; TRANSLOCATOR PROTEIN TSPO; 18; KDA; IN-VIVO; RADIOSYNTHESIS; BINDING; LIGAND; BRAIN;
D O I
10.1186/s41181-021-00133-0
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background The translocator protein 18 kDa is recognised as an important biomarker for neuroinflammation due to its soaring expression in microglia. This process is common for various neurological disorders. DPA-714 is a potent TSPO-specific ligand which found its use in Positron Emission Tomography following substitution of fluorine-19 with fluorine-18, a positron-emitting radionuclide. [F-18]DPA-714 enables visualisation of inflammatory processes in vivo non-invasively. Radiolabelling of this tracer is well described in literature, including validation for clinical use. Here, we report significant enhancements to the process which resulted in the design of a fully GMP-compliant robust synthesis of [F-18]DPA-714 on a popular cassette-based system, Trasis AllinOne, boosting reliability, throughput, and introducing a significant degree of simplicity. Results [F-18]DPA-714 was synthesised using the classic nucleophilic aliphatic substitution on a good leaving group, tosylate, with [F-18]fluoride using tetraethylammonium bicarbonate in acetonitrile at 100(circle)C. The process was fully automated on a Trasis AllinOne synthesiser using an in-house designed cassette and sequence. With a relatively small precursor load of 4 mg, [F-18]DPA-714 was obtained with consistently high radiochemical yields of 55-71% (n=6) and molar activities of 117-350 GBq/mu mol at end of synthesis. With a single production batch, starting with 31-42 GBq of [F-18]fluoride, between 13-20 GBq of the tracer can be produced, enabling multi-centre studies. Conclusion To the best of our knowledge, the process presented herein is the most efficient [F-18]DPA-714 synthesis, with advantageous GMP compliance. The use of a Trasis AllinOne synthesiser increases reliability and allows rapid training of production staff.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Optimised GMP-compliant production of [18F]DPA-714 on the Trasis AllinOne module
    Klaudia A. Cybulska
    Vera Bloemers
    Lars R. Perk
    Peter Laverman
    EJNMMI Radiopharmacy and Chemistry, 6
  • [2] An automated radiosynthesis of [18F]DPA-714 on a commercially available radiosynthesizer, Elixys Flex/Chem
    McCauley, Katelyenn S.
    Wilde, Justin H.
    Bufalino, Sophia M.
    Neumann, Kiel D.
    APPLIED RADIATION AND ISOTOPES, 2022, 180
  • [3] Initial evaluation in healthy humans of [18F]DPA-714, a potential PET biomarker for neuroinflammation
    Arlicot, Nicolas
    Vercouillie, Johnny
    Ribeiro, Maria-Joao
    Tauber, Clovis
    Venel, Yann
    Baulieu, Jean-Louis
    Maia, Serge
    Corcia, Philippe
    Stabin, Michael G.
    Reynolds, Aaron
    Kassiou, Michael
    Guilloteau, Denis
    NUCLEAR MEDICINE AND BIOLOGY, 2012, 39 (04) : 570 - 578
  • [4] [18F]DPA-714 as a biomarker for positron emission tomography imaging of rheumatoid arthritis in an animal model
    Pottier, Geraldine
    Bernards, Nicholas
    Dolle, Frederic
    Boisgard, Raphael
    ARTHRITIS RESEARCH & THERAPY, 2014, 16 (02)
  • [5] Automated radiosynthesis of [18F]DPA-714 on a commercially available IBA Synthera®
    Vavere, Amy L.
    Ghosh, Arijit
    Diaz, Victor Amador
    Clay, Allison J.
    Hall, Peter M.
    Neumann, Kiel D.
    APPLIED RADIATION AND ISOTOPES, 2024, 207
  • [6] Metabolism and Quantification of [18F] DPA-714, a New TSPO Positron Emission Tomography Radioligand
    Peyronneau, Marie-Anne
    Saba, Wadad
    Goutal, Sebastien
    Damont, Annelaure
    Dolle, Frederic
    Kassiou, Michael
    Bottlaender, Michel
    Valette, Heric
    DRUG METABOLISM AND DISPOSITION, 2013, 41 (01) : 122 - 131
  • [7] [18F]DPA-C5yne, a novel fluorine-18-labelled analogue of DPA-714: radiosynthesis and preliminary evaluation as a radiotracer for imaging neuroinflammation with PET
    Medran-Navarrete, Vincent
    Bernards, Nicholas
    Kuhnast, Bertrand
    Damont, Annelaure
    Pottier, Geraldine
    Peyronneau, Marie-Anne
    Kassiou, Michael
    Marguet, Frank
    Puech, Frederic
    Boisgard, Raphael
    Dolle, Frederic
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2014, 57 (06) : 410 - 418
  • [8] [18F]DPA-714 PET Imaging of AMD3100 Treatment in a Mouse Model of Stroke
    Wang, Yu
    Yue, Xuyi
    Kiesewetter, Dale O.
    Wang, Zhe
    Lu, Jie
    Niu, Gang
    Teng, Gaojun
    Chen, Xiaoyuan
    MOLECULAR PHARMACEUTICS, 2014, 11 (10) : 3463 - 3470
  • [9] Detection of Neuroinflammation in a Rat Model of Subarachnoid Hemorrhage Using [18F]DPA-714 PET Imaging
    Thomas, Clement
    Vercouillie, Johnny
    Domene, Aurelie
    Tauber, Clovis
    Kassiou, Michael
    Guilloteau, Denis
    Destrieux, Christophe
    Serriere, Sophie
    Chalon, Sylvie
    MOLECULAR IMAGING, 2016, 15
  • [10] Evaluation of the PBR/TSPO radioligand [18F]DPA-714 in a rat model of focal cerebral ischemia
    Martin, Abraham
    Boisgard, Raphael
    Theze, Benoit
    Van Camp, Nadja
    Kuhnast, Bertrand
    Damont, Annelaure
    Kassiou, Michael
    Dolle, Frederic
    Tavitian, Bertrand
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2010, 30 (01) : 230 - 241