High-resolution x-ray imaging using a structured scintillator

被引:35
作者
Hormozan, Yashar [1 ]
Sychugov, Ilya [1 ]
Linnros, Jan [1 ]
机构
[1] KTH Royal Inst Technol, Mat & Nano Phys, Sch Informat & Commun Technol, Electrum 229, S-16440 Stockholm, Sweden
关键词
structured scintillator; modulation transfer function (MTF); caesium iodide (CsI); detector; x-ray; microscope; MICROTOMOGRAPHY;
D O I
10.1118/1.4939258
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this study, the authors introduce a new generation of finely structured scintillators with a very high spatial resolution (a few micrometers) compared to conventional scintillators, yet maintaining a thick absorbing layer for improved detectivity. Methods: Their concept is based on a 2D array of high aspect ratio pores which are fabricated by ICP etching, with spacings (pitches) of a few micrometers, on silicon and oxidation of the pore walls. The pores were subsequently filled by melting of powdered CsI(Tl), as the scintillating agent. In order to couple the secondary emitted photons of the back of the scintillator array to a CCD device, having a larger pixel size than the pore pitch, an open optical microscope with adjustable magnification was designed and implemented. By imaging a sharp edge, the authors were able to calculate the modulation transfer function (MTF) of this finely structured scintillator. Results: The x-ray images of individually resolved pores suggest that they have been almost uniformly filled, and the MTF measurements show the feasibility of a few microns spatial resolution imaging, as set by the scintillator pore size. Compared to existing techniques utilizing CsI needles as a structured scintillator, their results imply an almost sevenfold improvement in resolution. Finally, high resolution images, taken by their detector, are presented. Conclusions: The presented work successfully shows the functionality of their detector concept for high resolution imaging and further fabrication developments are most likely to result in higher quantum efficiencies. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:696 / 701
页数:6
相关论文
共 21 条
[1]   Thin photodiodes for a scintillator-silicon well detector [J].
Allier, CP ;
Hollander, RW ;
Sarro, PM ;
van Eijk, CWE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) :1948-1951
[2]   Metallized and oxidized silicon macropore arrays filled with a scintillator for CCD-based X-ray imaging detectors [J].
Badel, X ;
Linnros, J ;
Kleimann, P ;
Norlin, B ;
Koskiahde, E ;
Valpas, K ;
Nenonen, S ;
Petersson, CS ;
Fröjdh, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) :1001-1005
[3]  
Beutel J., 2000, HDB MED IMAGING, V1, P203
[4]  
Burns P., 2009, SFRMAT3 V1
[5]   Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector [J].
Cho, Hyo-Min ;
Ding, Huanjun ;
Barber, William C. ;
Iwanczyk, Jan S. ;
Molloi, Sabee .
MEDICAL PHYSICS, 2015, 42 (07) :4401-4410
[6]   Free software for performing physical analysis of systems for digital radiography and mammography [J].
Donini, Bruno ;
Rivetti, Stefano ;
Lanconelli, Nico ;
Bertolini, Marco .
MEDICAL PHYSICS, 2014, 41 (05)
[7]   A comparative study of automatic thresholding approaches for 3D x-ray microtomography of trabecular bone [J].
Gomez, W. ;
Sales, E. ;
Lopes, R. T. ;
Pereira, W. C. A. .
MEDICAL PHYSICS, 2013, 40 (09)
[8]   Towards High-Resolution X-Ray Imaging Using a Structured Scintillator [J].
Hormozan, Yashar ;
Yun, Sang-Ho ;
Svenonius, Olof ;
Linnros, Jan .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) :19-23
[9]   An X-ray imaging detector based on pixel structured scintillator [J].
Kim, Byoung-Jik ;
Cho, Gyuseong ;
Cha, Bo Kyung ;
Kang, Bosun .
RADIATION MEASUREMENTS, 2007, 42 (08) :1415-1418
[10]   Scintillator and CMOS APS imager for radiography conditions [J].
Kim, Kwang Hyun ;
Kim, Young Soo .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1327-1332