Patient-specific model of brain deformation: Application to medical image registration

被引:131
作者
Wittek, Adam
Miller, Karol
Kikinis, Ron
Warfield, Simon K.
机构
[1] Univ Western Australia, Sch Mech Engn, Intelligent Syst Med Lab, Perth, WA 6009, Australia
[2] Brigham & Womens Hosp, Computat Radiol Lab, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
brain; image registration; finite element method; geometric and material non-linearity; explicit time integration;
D O I
10.1016/j.jbiomech.2006.02.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This contribution presents finite element computation of the deformation field within the brain during craniotomy-induced brain shift. The results were used to illustrate the capabilities of non-linear (i.e. accounting for both geometric and material non-linearities) finite element analysis in non-rigid registration of pre- and intra-operative magnetic resonance images of the brain. We used patient-specific hexahedron-dominant finite element mesh, together with realistic material properties for the brain tissue and appropriate contact conditions at boundaries. The model was loaded by the enforced motion of nodes (i.e. through prescribed motion of a boundary) at the brain surface in the craniotomy area. We suggest using explicit time-integration scheme for discretised equations of motion, as the computational times are much shorter and accuracy, for practical purposes, the same as in the case of implicit integration schemes. Application of the computed deformation field to register (i.e. align) the pre-operative images with the intraoperative ones indicated that the model very accurately predicts the displacements of the tumour and the lateral ventricles even for limited information about the brain surface deformation. The prediction accuracy improves when information about deformation of not only exposed (during craniotomy) but also unexposed parts of the brain surface is used when prescribing loading. However, it appears that the accuracy achieved using information only about the deformation of the exposed surface, that can be determined without intra-operative imaging, is acceptable. The presented results show that non-linear biomechanical models can complement medical image processing techniques when conducting non-rigid registration. Important advantage of such models over the previously used linear ones is that they do not require unrealistic assumptions that brain deformations are infinitesimally small and brain stress-strain relationship is linear. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:919 / 929
页数:11
相关论文
共 46 条
[1]  
*ABAQUS, 1998, ABAQUS THEORY MAN VE
[2]  
Bathe K, 2007, Finite element procedures
[3]   The computation of optical flow [J].
Beauchemin, SS ;
Barron, JL .
ACM COMPUTING SURVEYS, 1995, 27 (03) :433-467
[4]   ASSUMED STRAIN STABILIZATION OF THE 8 NODE HEXAHEDRAL ELEMENT [J].
BELYTSCHKO, T ;
BINDEMAN, LP .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1993, 105 (02) :225-260
[5]  
Belytschko T., 1983, Computational methods for transient analysis, P1
[6]   SURVEY OF NUMERICAL-METHODS AND COMPUTER-PROGRAMS FOR DYNAMIC STRUCTURAL-ANALYSIS [J].
BELYTSCHKO, T .
NUCLEAR ENGINEERING AND DESIGN, 1976, 37 (01) :23-34
[7]  
BREWWER JC, 2001, P 17 C ENH SAF VEH A
[8]  
BUCHOLZ R, 2004, CLIN NEUROSURG, V51, P227
[9]  
Castellano-Smith AD, 2001, LECT NOTES COMPUTER, P1091, DOI DOI 10.1007/3-540-45468-3_130
[10]  
Ciarlet P. G., 1988, MATH ELASTICITY