Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

被引:0
作者
Mazloum-Ardakani, Mohammad [1 ]
Abolhasani-Soorki, Mahboobe [1 ]
Khoshroo, Alireza [1 ]
Sabaghian, Fariba [1 ]
Mirjalili, Bibi-Fatemeh [1 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd, Iran
来源
IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH | 2018年 / 17卷 / 03期
关键词
Sensor; Ascorbic acid; Uric Acid; Tryptophan; Carbon nanotube; AMPEROMETRIC DETERMINATION; ELECTROCHEMICAL SENSOR; LIQUID DETERMINATION; LIPID-PEROXIDATION; GRAPHITE COMPOSITE; FOLIC-ACID; ACETAMINOPHEN; ISOPROTERENOL; LEVODOPA; GRAPHENE;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((lE)-(l,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-l,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhanced significantly relative to the situation prevailing when an unmodified carbon paste electrode was used. Cyclic voltammetry was used to investigate the redox properties of this modified electrode at various solution pH values and at various scan rates. Using differential pulse voltammetry, the calibration curves for AA were obtained over the range of 1.0-80.0 and 80-4000.0 mu M, respectively. The detection limit was 0.3 mu M. The present method provides a simple method for selective detection of ascorbic acid. DPV also was used for simultaneous determination of AA, uric acid, and tryptophan at the modified electrode. Finally, the proposed electrochemical sensor was used for determinations of these substances in in biological systems and pharmaceutical samples.
引用
收藏
页码:851 / 863
页数:13
相关论文
共 42 条
[11]   Correlation between blood antioxidant levels and lipid peroxidation in rheumatoid arthritis [J].
Gambhir, JK ;
Lali, P ;
Jain, AK .
CLINICAL BIOCHEMISTRY, 1997, 30 (04) :351-355
[12]  
Geno PW, J ELECTROANAL
[13]  
Halliwell B., 1999, FREE RADICAL BIO MED, P351
[14]  
Heli H, 2015, IRAN J PHARM RES, V14, P453
[15]   A sensitive nanocomposite-based electrochemical sensor for voltammetric simultaneous determination of isoproterenol, acetaminophen and tryptophan [J].
Karimi-Maleh, Hassan ;
Moazampour, Mahbobeh ;
Ahmar, Hamid ;
Beitollahi, Hadi ;
Ensafi, Ali A. .
MEASUREMENT, 2014, 51 :91-99
[16]   Modified multiwalled carbon nanotubes paste electrode as a sensor for the electrocatalytic determination of N-acetylcysteine in the presence of high concentrations of folic acid [J].
Keyvanfard, Mohsen ;
Ensafi, Ali A. ;
Karimi-Maleh, Hassan ;
Alizad, Khadijeh .
ANALYTICAL METHODS, 2012, 4 (10) :3268-3274
[17]  
Laviron E, J ELECTROANAL CHEM I
[18]   Dissection of the binding of L-ascorbic acid to trypsin and pepsin using isothermal titration calorimetry, equilibrium microdialysis and spectrofluorimetry [J].
Li, Xiangrong ;
Yang, Zhijun .
RSC ADVANCES, 2015, 5 (45) :35487-35496
[19]   Flow injection analysis-amperometric determination of ascorbic and uric acids in urine using arrays of gold microelectrodes modified by electrodeposition of palladium [J].
Matos, RC ;
Augelli, MA ;
Lago, CL ;
Angnes, L .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :151-157
[20]   Synthesis of TiO2 Nanoparticle and its Application to Graphite Composite Electrode for Hydroxylamine Oxidation [J].
Mazloum-Ardakani, M. ;
Khoshroo, A. R. .