Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

被引:0
作者
Mazloum-Ardakani, Mohammad [1 ]
Abolhasani-Soorki, Mahboobe [1 ]
Khoshroo, Alireza [1 ]
Sabaghian, Fariba [1 ]
Mirjalili, Bibi-Fatemeh [1 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd, Iran
来源
IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH | 2018年 / 17卷 / 03期
关键词
Sensor; Ascorbic acid; Uric Acid; Tryptophan; Carbon nanotube; AMPEROMETRIC DETERMINATION; ELECTROCHEMICAL SENSOR; LIQUID DETERMINATION; LIPID-PEROXIDATION; GRAPHITE COMPOSITE; FOLIC-ACID; ACETAMINOPHEN; ISOPROTERENOL; LEVODOPA; GRAPHENE;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((lE)-(l,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-l,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhanced significantly relative to the situation prevailing when an unmodified carbon paste electrode was used. Cyclic voltammetry was used to investigate the redox properties of this modified electrode at various solution pH values and at various scan rates. Using differential pulse voltammetry, the calibration curves for AA were obtained over the range of 1.0-80.0 and 80-4000.0 mu M, respectively. The detection limit was 0.3 mu M. The present method provides a simple method for selective detection of ascorbic acid. DPV also was used for simultaneous determination of AA, uric acid, and tryptophan at the modified electrode. Finally, the proposed electrochemical sensor was used for determinations of these substances in in biological systems and pharmaceutical samples.
引用
收藏
页码:851 / 863
页数:13
相关论文
共 42 条
[1]   Ascorbic acid: much more than just an antioxidant [J].
Arrigoni, O ;
De Tullio, MC .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2002, 1569 (1-3) :1-9
[2]   Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites [J].
Banks, CE ;
Davies, TJ ;
Wildgoose, GG ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2005, (07) :829-841
[3]  
Bard AJ, 2001, ELECTROCHEMICAL METH, P421
[4]   Electrochemical sensors and biosensors based on redox polymer/carbon nanotube modified electrodes: A review [J].
Barsan, Madalina M. ;
Ghica, M. Emilia ;
Brett, Christopher M. A. .
ANALYTICA CHIMICA ACTA, 2015, 881 :1-23
[5]   Dual electrode micro-channel flow cell for redox titrations: Kinetics and analysis of homogeneous ascorbic acid oxidation [J].
Bitziou, Eleni ;
Snowden, Michael E. ;
Joseph, Maxim B. ;
Leigh, Simon J. ;
Covington, James A. ;
Macpherson, Julie V. ;
Unwin, Patrick R. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 692 :72-79
[6]   Determination of electroactive organic acids by anion-exchange chromatography using a copper modified electrode [J].
Casella, IG ;
Gatta, M .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (02) :223-233
[7]   Chemical oxidation of multiwalled carbon nanotubes [J].
Datsyuk, V. ;
Kalyva, M. ;
Papagelis, K. ;
Parthenios, J. ;
Tasis, D. ;
Siokou, A. ;
Kallitsis, I. ;
Galiotis, C. .
CARBON, 2008, 46 (06) :833-840
[8]  
Emadi M, 2014, J PHYS CHEM ELECTROC, V2, P86
[9]   Sensitive voltammetric determination of diclofenac using room-temperature ionic liquid-modified carbon nanotubes paste electrode [J].
Ensafi, Ali A. ;
Izadi, Maedeh ;
Karimi-Maleh, Hassan .
IONICS, 2013, 19 (01) :137-144
[10]  
Galus Z, 1976, FUNDAMENTALS ELECTRO, P121