Analytical expressions for the reconstructed image of a homogeneous cylindrical sample exhibiting a beam hardening artifact in X-ray computed tomography

被引:5
作者
Nakano, Tsukasa [1 ]
Nakashima, Yoshito [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Cent 7,Higashi 1-1-1, Tsukuba, Ibaraki 3058567, Japan
基金
日本学术振兴会;
关键词
Beam hardening; cupping artifact; exact solution; phantom; polychromatic X-ray spectrum; X-ray CT; SPECTRUM ESTIMATION; CT;
D O I
10.3233/XST-18378
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Cylindrical phantoms are often imaged by X-ray computed tomography (CT) to evaluate the extent of beam hardening (or cupping artifact) resulting from a polychromatic X-ray source. OBJECTIVE: Our goal was to derive analytical expressions for the reconstructed image of a homogeneous cylindrical phantom exhibiting a cupping artifact, to permit a quantitative comparison with experimental cupping data. METHODS: A filtered backprojection method was employed to obtain the analytical cupping profile for the phantom, assuming that the projection data could be approximated as a power series with respect to the sample penetration thickness. RESULTS: The cupping profile was obtained analytically as a series of functions by employing Ramachandran filtering with an infinite Nyquist wavenumber. The quantitative relationship between the power series of the projection and the nth moment of the linear attenuation coefficient spectrum of the phantom was also determined. Application of the obtained cupping profile to the evaluation of the practical reconstruction filters with a finite Nyquist wavenumber and to the best choice of the contrast agent was demonstrated. CONCLUSIONS: The set of exact solutions derived in this work should be applicable to the analysis of cylindrical phantom experiments intended to evaluate CT systems.
引用
收藏
页码:691 / 705
页数:15
相关论文
共 50 条
  • [41] Cupping artifacts correction for polychromatic X-ray cone-beam computed tomography based on projection compensation and hardening behavior
    Yang, Fuqiang
    Zhang, Dinghua
    Zhang, Hua
    Huang, Kuidong
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [42] X-ray Cone-Beam Breast Computed Tomography: phantom studies
    Russo, P.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4076 - 4083
  • [43] X-ray Cone-Beam Breast Computed Tomography: Phantom Studies
    Russo, Paolo
    Mettivier, Giovanni
    Lauria, Adele
    Montesi, Maria Cristina
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 160 - 172
  • [44] Multi-mounted X-ray cone-beam computed tomography
    Fu, Jian
    Wang, Jingzheng
    Guo, Wei
    Peng, Peng
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 119 - 125
  • [45] Optimized Intensity Modulation for a Dynamic Beam Attenuator in X-ray Computed Tomography
    Huck, Sascha Manuel
    Fung, George S. K.
    Parodi, Katia
    Stierstorfer, Karl
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [46] RECONSTRUCTION TECHNIQUE OF FLUORESCENT X-RAY COMPUTED TOMOGRAPHY USING SHEET BEAM
    Nakamura, Shunsuke
    Huo, Qingkai
    Yuasa, Tetsuya
    [J]. 2014 PROCEEDINGS OF THE 22ND EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2014, : 1975 - 1979
  • [47] Empirical beam hardening and ring artifact correction for x-ray grating interferometry (EBHC-GI)
    Nelson, Brandon J.
    Leng, Shuai
    Shanblatt, Elisabeth R.
    McCollough, Cynthia H.
    Koenig, Thomas
    [J]. MEDICAL PHYSICS, 2021, 48 (03) : 1327 - 1340
  • [48] Quantitative evaluation of the effect of changes in effective energy on the image quality in X-ray computed tomography
    Ishiguro, Ayana
    Sato, Kazuhiro
    Taura, Masaaki
    Hoshi, Hideki
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 567 - 575
  • [49] Nondestructive Quantification of Heavy Elements Through the Analysis of Beam Hardening Artifacts Using Double-Exposure X-ray Computed Tomography: A Theoretical Consideration
    Nakashima, Yoshito
    Nakano, Tsukasa
    [J]. CHEMISTRY AFRICA-A JOURNAL OF THE TUNISIAN CHEMICAL SOCIETY, 2020, 3 (02): : 363 - 370
  • [50] Effect of Tube Setting on Image Quality in Industrial X-ray Computed Tomography
    Sun, Zhaoying
    Li, Lei
    Xi, Xiaoqi
    Han, Yu
    Yan, Bin
    Rong, Lihui
    Zhou, Sangsang
    [J]. THREE-DIMENSIONAL IMAGE ACQUISITION AND DISPLAY TECHNOLOGY AND APPLICATIONS, 2018, 10845