Analytical expressions for the reconstructed image of a homogeneous cylindrical sample exhibiting a beam hardening artifact in X-ray computed tomography

被引:5
作者
Nakano, Tsukasa [1 ]
Nakashima, Yoshito [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Cent 7,Higashi 1-1-1, Tsukuba, Ibaraki 3058567, Japan
基金
日本学术振兴会;
关键词
Beam hardening; cupping artifact; exact solution; phantom; polychromatic X-ray spectrum; X-ray CT; SPECTRUM ESTIMATION; CT;
D O I
10.3233/XST-18378
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Cylindrical phantoms are often imaged by X-ray computed tomography (CT) to evaluate the extent of beam hardening (or cupping artifact) resulting from a polychromatic X-ray source. OBJECTIVE: Our goal was to derive analytical expressions for the reconstructed image of a homogeneous cylindrical phantom exhibiting a cupping artifact, to permit a quantitative comparison with experimental cupping data. METHODS: A filtered backprojection method was employed to obtain the analytical cupping profile for the phantom, assuming that the projection data could be approximated as a power series with respect to the sample penetration thickness. RESULTS: The cupping profile was obtained analytically as a series of functions by employing Ramachandran filtering with an infinite Nyquist wavenumber. The quantitative relationship between the power series of the projection and the nth moment of the linear attenuation coefficient spectrum of the phantom was also determined. Application of the obtained cupping profile to the evaluation of the practical reconstruction filters with a finite Nyquist wavenumber and to the best choice of the contrast agent was demonstrated. CONCLUSIONS: The set of exact solutions derived in this work should be applicable to the analysis of cylindrical phantom experiments intended to evaluate CT systems.
引用
收藏
页码:691 / 705
页数:15
相关论文
共 50 条
  • [31] Mouse livers machine learning identification based on hyperspectral x-ray computed tomography reconstructed x-ray absorption spectra
    Fang, Zheng
    Zhong, Shuo
    Hu, Weifeng
    Cheng, Siyuan
    AIP ADVANCES, 2020, 10 (11)
  • [32] Assessing the influence of X-ray spectrum on image quality in abdominal computed tomography scans
    El Mansouri, M'hamed
    Talbi, Mohammed
    Khatar, Zakaria
    Nhila, Oussama
    Sekkat, Hamza
    Tahiri, Zakaria
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2024, 179 (9-10): : 1178 - 1187
  • [33] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don
    MATERIALS EVALUATION, 2020, 78 (02) : 203 - 212
  • [34] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don (don.roth@bhge.com), 1600, American Society for Nondestructive Testing (78): : 203 - 212
  • [35] Fast Correction of Analytical Reconstructions in Sparse View X-ray Computed Tomography
    Trinca, D.
    Zhong, Y.
    Royuela-del-Val, J.
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 1109 - 1115
  • [36] A Practical Computed Tomography Image Ring Artifact Correction Method for Large-Scale Dead Pixels of X-ray Detector
    Yuan, Cuiyun
    Chen, Zijia
    Qi, Hongliang
    Wu, Shuyu
    Li, Bin
    Ma, Jianhui
    Zhou, Linghong
    Xu, Yuan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (05) : 950 - 958
  • [37] X-Ray attenuation and image contrast in the X-ray computed tomography of clathrate hydrates depending on guest species
    Takeya, Satoshi
    Muromachi, Sanehiro
    Hachikubo, Akihiro
    Ohmura, Ryo
    Hyodo, Kazuyuki
    Yoneyama, Akio
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2020, 22 (47) : 27658 - 27665
  • [38] Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD
    Meganck, Jeffrey A.
    Kozloff, Kenneth M.
    Thornton, Michael M.
    Broski, Stephen M.
    Goldstein, Steven A.
    BONE, 2009, 45 (06) : 1104 - 1116
  • [39] Metal artifact correction for x-ray computed tomography using kV and selective MV imaging
    Wu, Meng
    Keil, Andreas
    Constantin, Dragos
    Star-Lack, Josh
    Zhu, Lei
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2014, 41 (12)
  • [40] Metal artifact removal (MAR) analysis for the security inspections using the X-ray computed tomography
    Cho, Hyo Sung
    Woo, Tae Ho
    Park, Chul Kyu
    RADIATION PHYSICS AND CHEMISTRY, 2016, 127 : 42 - 47