Analytical expressions for the reconstructed image of a homogeneous cylindrical sample exhibiting a beam hardening artifact in X-ray computed tomography

被引:5
|
作者
Nakano, Tsukasa [1 ]
Nakashima, Yoshito [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Cent 7,Higashi 1-1-1, Tsukuba, Ibaraki 3058567, Japan
基金
日本学术振兴会;
关键词
Beam hardening; cupping artifact; exact solution; phantom; polychromatic X-ray spectrum; X-ray CT; SPECTRUM ESTIMATION; CT;
D O I
10.3233/XST-18378
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Cylindrical phantoms are often imaged by X-ray computed tomography (CT) to evaluate the extent of beam hardening (or cupping artifact) resulting from a polychromatic X-ray source. OBJECTIVE: Our goal was to derive analytical expressions for the reconstructed image of a homogeneous cylindrical phantom exhibiting a cupping artifact, to permit a quantitative comparison with experimental cupping data. METHODS: A filtered backprojection method was employed to obtain the analytical cupping profile for the phantom, assuming that the projection data could be approximated as a power series with respect to the sample penetration thickness. RESULTS: The cupping profile was obtained analytically as a series of functions by employing Ramachandran filtering with an infinite Nyquist wavenumber. The quantitative relationship between the power series of the projection and the nth moment of the linear attenuation coefficient spectrum of the phantom was also determined. Application of the obtained cupping profile to the evaluation of the practical reconstruction filters with a finite Nyquist wavenumber and to the best choice of the contrast agent was demonstrated. CONCLUSIONS: The set of exact solutions derived in this work should be applicable to the analysis of cylindrical phantom experiments intended to evaluate CT systems.
引用
收藏
页码:691 / 705
页数:15
相关论文
共 50 条
  • [21] JOINT REDUCE OF METAL AND BEAM HARDENING ARTIFACTS USING MULTI-ENERGY MAP APPROACH IN X-RAY COMPUTED TOMOGRAPHY
    Zheng, Yuling
    Cai, Caifang
    Rodet, Thomas
    2011 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2011, : 737 - 740
  • [22] Image-based Metal Artifact Reduction in X-ray Computed Tomography utilizing Local Anatomical Similarity
    Dong, Xue
    Yang, Xiaofeng
    Rosenfield, Jonathan
    Elder, Eric
    Dhabaan, Anees
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [23] Statistical image reconstruction for polyenergetic X-ray computed tomography
    Elbakri, IA
    Fessler, JA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) : 89 - 99
  • [24] Photon-counting X-ray computed tomography using a YAP(Ce)-PMT detector and beam hardening
    Watanabe, Manabu
    Sato, Eiichi
    Yoshida, Sohei
    Yoshioka, Kunihiro
    Oda, Yasuyuki
    Moriyama, Hodaka
    Hagiwara, Osahiko
    Enomoto, Toshiyuki
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXI, 2019, 11114
  • [25] Automated high accuracy, rapid beam hardening correction in X-Ray Computed Tomography of multi-mineral, heterogeneous core samples
    Romano, Carla
    Minto, James M.
    Shipton, Zoe K.
    Lunn, Rebecca J.
    COMPUTERS & GEOSCIENCES, 2019, 131 : 144 - 157
  • [26] Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage
    Liu, Tianshuai
    Rong, Junyan
    Gao, Peng
    Zhang, Wenli
    Liu, Wenlei
    Zhang, Yuanke
    Lu, Hongbing
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (02)
  • [27] The use of sodium polytungstate as an X-ray contrast agent to reduce the beam hardening artifact in hydrological laboratory experiments
    Nakashima, Yoshito
    JOURNAL OF HYDROLOGY AND HYDROMECHANICS, 2013, 61 (04) : 347 - U94
  • [28] Sparsity Constrained Sinogram Inpainting for Metal Artifact Reduction in X-ray Computed Tomography
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3694 - 3699
  • [29] A Constrained Optimization Reconstruction Model for X-ray Computed Tomography Metal Artifact Suppression
    Li, Ming
    Zheng, Jian
    Zhou, Shihui
    Yuan, Gang
    Wu, Zhongyi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (07) : 1543 - 1547
  • [30] Mouse livers machine learning identification based on hyperspectral x-ray computed tomography reconstructed x-ray absorption spectra
    Fang, Zheng
    Zhong, Shuo
    Hu, Weifeng
    Cheng, Siyuan
    AIP ADVANCES, 2020, 10 (11)