Low Noise Detection of Biomolecular Interactions with Signal-Locking Surface Plasmon Resonance

被引:10
作者
Williams, Layne D. [1 ]
Ghosh, Tridib [2 ]
Mastrangelo, Carlos H. [1 ,2 ]
机构
[1] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
关键词
CARBONIC-ANHYDRASE; TECHNOLOGY; BIOSENSOR; BINDING; LIGANDS; PROTEIN; MODEL;
D O I
10.1021/ac100504b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Surface plasmon resonance (SPR) is a popular technique for label-free detection of biomolecular interactions at a surface. SPR yields quantitative kinetic association and dissociation constants of surface interactions such as the binding of two molecular species, one present in the liquid phase and the other immobilized at the surface. Current state-of-the-art SPR systems extract kinetic constants from measurements of the step response of the interaction versus time. The step response measurement is subject to the influence of noise and drift disturbances that limit its minimum-detectable mass changes. This paper presents a new SPR technique that measures the biomolecular interaction not in time but over a very narrow frequency range under periodic excitation. The measured response is, thus, locked to a very specific narrow band signal. This narrow band spectral sensing scheme has a very high degree of rejection to uncorrelated spurious signals. The signal-locked SPR technique was implemented using a chemical modulator chip connected to a set of functionalized Au sensing sites downstream. Binding experiments for a model system of carbonic anhydrase-II (CA-II) analyte and immobilized 4-(2-aminoethyl)benzenesulfonamide (ABS) ligand display a 100-fold (20 dB) improvement in the measured signal-to-noise ratio (SNR) when using the new technique compared to the SNR achieved using the conventional step response method.
引用
收藏
页码:6025 / 6031
页数:7
相关论文
共 15 条
[1]   BIACORE data processing: An evaluation of the global fitting procedure [J].
Ben Khalifa, M ;
Choulier, L ;
Lortat-Jacob, H ;
Altschuh, D ;
Vernet, T .
ANALYTICAL BIOCHEMISTRY, 2001, 293 (02) :194-203
[2]   Generation of dynamic chemical signals with microfluidic C-DACs [J].
Chen, L. ;
Azizi, F. ;
Mastrangelo, C. H. .
LAB ON A CHIP, 2007, 7 (07) :850-855
[3]  
Giancoli D., 1989, Physics for Scientists and Engineers
[4]  
JONSSON U, 1991, BIOTECHNIQUES, V11, P620
[5]   Carbonic anhydrase as a model for biophysical and physical-organic studies of proteins and protein-ligand binding [J].
Krishnamurthy, Vijay M. ;
Kaufman, George K. ;
Urbach, Adam R. ;
Gitlin, Irina ;
Gudiksen, Katherine L. ;
Weibel, Douglas B. ;
Whitesides, George M. .
CHEMICAL REVIEWS, 2008, 108 (03) :946-1051
[6]   Biospecific binding of carbonic anhydrase to mixed SAMs presenting benzenesulfonamide ligands: A model system for studying lateral steric effects [J].
Lahiri, J ;
Isaacs, L ;
Grzybowski, B ;
Carbeck, JD ;
Whitesides, GM .
LANGMUIR, 1999, 15 (21) :7186-7198
[7]   A NOVEL HYDROGEL MATRIX ON GOLD SURFACES IN SURFACE-PLASMON RESONANCE SENSORS FOR FAST AND EFFICIENT COVALENT IMMOBILIZATION OF LIGANDS [J].
LOFAS, S ;
JOHNSSON, B .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1990, (21) :1526-1528
[8]  
Moon T.K., 2000, Mathematical Methods and Algorithms for Signal Processing
[9]  
Myszyka DG, 1999, J MOL RECOGNIT, V12, P279, DOI 10.1002/(SICI)1099-1352(199909/10)12:5<279::AID-JMR473>3.0.CO
[10]  
2-3