Flow injection amperometric sandwich-type aptasensor for the determination of human leukemic lymphoblast cancer cells using MWCNTs-Pdnano/PTCA/aptamer as labeled aptamer for the signal amplification

被引:32
作者
Tabrizi, Mahmoud Amouzadeh [1 ]
Shamsipur, Mojtaba [2 ]
Saber, Reza [3 ,4 ]
Sarkar, Saeed [3 ,5 ]
机构
[1] Kermanshah Univ Med Sci, Nano Drug Delivery Res Ctr, Kermanshah, Iran
[2] Razi Univ, Dept Chem, Kermanshah, Iran
[3] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[4] Univ Tehran Med Sci, Sch Adv Technol Med, Tehran, Iran
[5] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
关键词
Flow injection amperometric; Sandwich-type aptasensor; MWCNTs-Pdnano; CCRF-CEM cancer cell; GLASSY-CARBON ELECTRODE; SENSITIVE ELECTROCHEMICAL APTASENSOR; ULTRASENSITIVE DETECTION; GOLD NANOPARTICLES; HYDROGEN-PEROXIDE; GRAPHENE OXIDE; ELECTROCHEMILUMINESCENCE APTASENSOR; MULTIVALENT RECOGNITION; MOLYBDENUM-DISULFIDE; CONDUCTING POLYMER;
D O I
10.1016/j.aca.2017.07.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, we demonstrated a flow injection amperometric sandwich-type aptasensor for the determination of human leukemic lymphoblasts (CCRF-CEM) based on poly(3,4-ethylenedioxythiophene) decorated with gold nanoparticles (PEDOT-Aunano) as a nano platform to immobilize thiolated sgc8c aptamer and multiwall carbon nanotubes decorated with palladium nanoparticles/3,4,9,10-perylene tetracarboxylic acid (MWCNTs-Pd-nano/PTCA) to fabricate catalytic labeled aptamer. In the proposed sensing strategy, the CCRF-CEM cancer cells were sandwiched between immobilized sgc8c aptamer on PEDOT-Au-nano modified surface electrode and catalytic labeled sgc8c aptamer (MWCNTs-Pd-nano/PTCA/aptamer). After that, the concentration of CCRF-CEM cancer cells was determined in presence of 0.1 mM hydrogen peroxide (H2O2) as an electroactive component. The attached MWCNTs-Pdnano nanocomposites to CCRF-CEM cancer cells amplified the electrocatalytic reduction of H2O2 and improved the sensitivity of the sensor to CCRF-CEM cancer cells. The MWCNT-Pd-nano nanocomposite was characterized with transmission electron microscopy (TEM) and energy dispersive X-ray (EDX). The electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to confirm the stepwise changes in the electrochemical surface properties of the electrode. The proposed sandwich-type electrochemical aptasensor exhibited an excellent analytical performance for the detection of CCRF-CEM cancer cells ranging from 1.0 x 10(1) to 5.0 x 10(5) cells mL(-1). The limit of detection was 8 cells mL(-1). The proposed aptasensor showed high selectivity toward CCRF-CEM cancer cells. The proposed aptasensor was also applied to the determination of CCRF-CEM cancer cells in human serum samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 72 条
[1]   Conducting polymer based electrochemical biosensors [J].
Aydemir, Nihan ;
Malmstroem, Jenny ;
Travas-Sejdic, Jadranka .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2016, 18 (12) :8264-8277
[2]   Highly sensitive electrochemical label-free aptasensor based on dual electrocatalytic amplification of Pt-AuNPs and HRP [J].
Bai, Lijuan ;
Yuan, Ruo ;
Chai, Yaqin ;
Yuan, Yali ;
Mao, Li ;
Zhuo, Ying .
ANALYST, 2011, 136 (09) :1840-1845
[3]   Visual and high-throughput detection of cancer cells using a graphene oxide-based FRET aptasensing microfluidic chip [J].
Cao, Lili ;
Cheng, Liwei ;
Zhang, Zhengyong ;
Wang, Yi ;
Zhang, Xianxia ;
Chen, Hui ;
Liu, Baohong ;
Zhang, Song ;
Kong, Jilie .
LAB ON A CHIP, 2012, 12 (22) :4864-4869
[4]   Pt NPs and DNAzyme functionalized polymer nanospheres as triple signal amplification strategy for highly sensitive electrochemical immunosensor of tumour marker [J].
Chang, Honghong ;
Zhang, Haochun ;
Lv, Jia ;
Zhang, Bing ;
Wei, Wenlong ;
Guo, Jingang .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :156-163
[5]   Development of amperometric lysine biosensors based on Au nanoparticles/multiwalled carbon nanotubes/polymers modified Au electrodes [J].
Chauhan, Nidhi ;
Singh, Anamika ;
Narang, Jagriti ;
Dahiya, Swati ;
Pundir, C. S. .
ANALYST, 2012, 137 (21) :5113-5122
[6]   Electrocatalytic hydrogenation of 4-chlorophenol on the glassy carbon electrode modified by composite polypyrrole/palladium film [J].
Chen, G ;
Wang, ZY ;
Yang, T ;
Huang, DD ;
Xia, DG .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (10) :4863-4868
[7]   Ultrasensitive detection of cancer cells and glycan expression profiling based on a multivalent recognition and alkaline phosphatase-responsive electrogenerated chemiluminescence biosensor [J].
Chen, Xiaojiao ;
He, Yao ;
Zhang, Youyu ;
Liu, Meiling ;
Liu, Yang ;
Li, Jinghong .
NANOSCALE, 2014, 6 (19) :11196-11203
[8]   Sensitive Electrochemical Aptamer Biosensor for Dynamic Cell Surface N-Glycan Evaluation Featuring Multivalent Recognition and Signal Amplification on a Dendrimer-Graphene Electrode Interface [J].
Chen, Xiaojiao ;
Wang, Yangzhong ;
Zhang, Youyu ;
Chen, Zhuhai ;
Liu, Yang ;
Li, Zhaolong ;
Li, Jinghong .
ANALYTICAL CHEMISTRY, 2014, 86 (09) :4278-4286
[9]   Fabrication of PEDOT nanowhiskers for electrical connection of the hemoglobin active center for H2O2 electrochemical biosensing [J].
Chen, Yun ;
Gai, Panpan ;
Jin, Li ;
Zhu, Dong ;
Tian, Danbi ;
Abdel-Halim, E. S. ;
Zhang, Jianrong ;
Zhu, Jun-Jie .
JOURNAL OF MATERIALS CHEMISTRY B, 2013, 1 (28) :3451-3457
[10]   THE METHYLENE-BLUE COLORIMETRIC MICROASSAY FOR DETERMINING CELL-LINE RESPONSE TO GROWTH-FACTORS [J].
DENT, MF ;
HUBBOLD, L ;
RADFORD, H ;
WILSON, AP .
CYTOTECHNOLOGY, 1995, 17 (01) :27-33