Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: Pharmacokinetic analysis and experimental porcine model

被引:102
作者
Bae, KT [1 ]
Tran, HQ [1 ]
Heiken, JP [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
animals; aorta; CT; computed tomography (CT); contrast enhancement; helical technology; computers; simulation; model; mathematical;
D O I
10.1148/radiology.216.3.r00au43872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if multiphasic injection provides uniform, prolonged vascular contrast medium enhancement at computed tomographic (CT) angiography. MATERIALS AND METHODS: With a computer-based, compartmental model of the cardiovascular system, theoretic analysis was performed to estimate an injection algorithm for uniform, prolonged vascular enhancement. For algorithm validation, four pigs were scanned after intravenous injection of 50 or 70 mL of contrast medium (282 mg of iodine per milliliter). Uni-, bi-, and multiphasic injection schemes were tested. In most cases, the initial injection rate was 2 mL/sec. In each CT study, 27 dynamic images were acquired every 2 seconds at a fixed mid-abdominal aortic level. Time-enhancement curves were calculated. injection duration, peak aortic enhancement, and enhancement uniformity (duration of enhancement achieved within 90% of the peak [90% DCE]) were evaluated. RESULTS: Theoretic and experimental results agreed well. Compared with uniphasic injection, biphasic injection resulted in more prolonged enhancement but generated two enhancement peaks with a valley between, and multiphasic injection yielded more uniform and prolonged enhancement. With 50- and 70-mL multiphasic injections, respectively, injection duration increased by 32% and 51%, peak enhancement decreased by 19% and 18%, and 90% DCE increased by 81% and 94%. CONCLUSION: Uniform, prolonged vascular enhancement, which is desirable for CT angiography and essential for steady-state quantification of blood volume in organs, can be achieved with multiphasic injection.
引用
收藏
页码:872 / 880
页数:9
相关论文
共 10 条
[1]   Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :647-655
[2]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[3]   Mathematical analysis of arterial enhancement and optimization of bolus geometry for CT angiography using the discrete Fourier transform [J].
Fleischmann, D ;
Hittmair, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) :474-484
[4]  
Guyton A C., TXB MED PHYSL
[5]  
HANNON JP, 1990, LAB ANIM SCI, V40, P293
[6]   DYNAMIC CONTRAST-ENHANCED CT OF THE LIVER - COMPARISON OF CONTRAST-MEDIUM INJECTION RATES AND UNIPHASIC AND BIPHASIC INJECTION PROTOCOLS [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
FORMAN, HP ;
DICROCE, J .
RADIOLOGY, 1993, 187 (02) :327-331
[7]   In vivo regional cerebral blood volume: Quantitative assessment with 3D T1-weighted pre- and postcontrast MR imaging [J].
Kuppusamy, K ;
Lin, WL ;
Cizek, GR ;
Haacke, EM .
RADIOLOGY, 1996, 201 (01) :106-112
[8]   Quantitative measurements of regional cerebral blood volume using MRI in rats: Effects of arterial carbon dioxide tension and mannitol [J].
Lin, WL ;
Paczynski, RP ;
Kuppusamy, K ;
Hsu, CY ;
Haacke, EM .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :420-428
[9]  
Press W. H., 1986, NUMERICAL RECIPES
[10]  
RUBIN GD, 1998, SPIRAL CT PRINCIPLES, P361