Noniterative Parameter-Free Fault Location on Untransposed Single-Circuit Transmission Lines

被引:27
|
作者
Dobakhshari, Ahmad Salehi [1 ]
机构
[1] Univ Guilan, Fac Engn, Dept Elect Engn, Rasht 4199613776, Iran
关键词
Bisymmetric matrix; fault location; impedance matrix; synchronized measurements; untransposed transmission line; ALGORITHM;
D O I
10.1109/TPWRD.2017.2650780
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Extra high voltage transmission networks include many untransposed single-circuit overhead lines with horizontal configuration of phase conductors. This paper develops a setting-free fault-location method specific to these types of transmission lines. Utilizing synchronized measurements at line terminals, the proposed method accurately locates faults irrespective of fault type, fault resistance, external network parameters, and faulted-line parameters. As such, fault location is robust against ambient conditions as well as inherent inaccuracy of line parameters. The bisymmetry of the impedance matrix of the line is utilized to obtain a closed-form solution for fault location on short transmission lines. For long transmission lines, shunt capacitance of the line is taken into account to obtain an accurate closed-form estimation for fault location. Electromagnetic transient simulation in PSCAD/EMTDC environment validates the accuracy of the proposed fault-location method for a long untransposed 400-kV transmission line. The obtained results are also compared with an existing noniterative parameter-free fault-location method to demonstrate salient features of the proposed method.
引用
收藏
页码:1636 / 1644
页数:9
相关论文
共 50 条
  • [21] Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm
    Minan Tang
    Hang Lu
    Bin Li
    Protection and Control of Modern Power Systems, 2023, 8
  • [22] Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm
    Tang, Minan
    Lu, Hang
    Li, Bin
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
  • [23] Unsynchronized Parameter-Free Fault Location for Two or Three Terminal Double-Circuit Transmission Lines Sharing the Same Tower via Unscented Kalman Filter
    Wang, Binglin
    Liu, Yu
    Lu, Dian
    Yue, Kang
    Nie, Yuan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (03) : 1731 - 1746
  • [24] The Power-frequency Parameter Measurement Method of Single-circuit Transmission Lines Based on Transmission Line Equation
    Cheng, Shuyi
    2015 INTERNATIONAL CONFERENCE ON NEW ENERGY SCIENCE AND RESEARCH (ICESR 2015), 2015, : 345 - 349
  • [25] A new fault location method for single-circuit three-terminal transmission lines based onfault branch determination and iterative calculation
    Chen X.
    Yu L.
    Pei D.
    Yuan S.
    Xue S.
    Jiang Y.
    Li S.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (20): : 1 - 11
  • [26] Coupling characteristic analysis and a fault Pole detection Scheme for single-circuit and double-circuit HVDC transmission lines
    Chu, Xu
    Lv, Haoze
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 181
  • [27] ELECTROSTATIC UNBALANCE OF UNTRANSPOSED SINGLE CIRCUIT LINES
    GROSS, ETB
    CHIN, W
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (01): : 24 - &
  • [28] Electromagnetic environment of 750 kV single-circuit compact transmission lines
    Wan, Bao-Quan
    Wu, Xiong
    Zhang, Ye-Mao
    Cao, Sheng-Shun
    Zhu, Yue
    Liu, Da-Shi
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 597 - 600
  • [29] New fault location scheme for three-terminal untransposed parallel transmission lines
    Saber, Ahmed
    Emam, Ahmed
    Elghazaly, Hany
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 154 : 266 - 275
  • [30] Fault Classification and Faulted Phase Selection Based on the Symmetrical Components of Reactive Power for Single-Circuit Transmission Lines
    Mahamedi, Behnam
    Zhu, Jian Guo