Noniterative Parameter-Free Fault Location on Untransposed Single-Circuit Transmission Lines

被引:27
|
作者
Dobakhshari, Ahmad Salehi [1 ]
机构
[1] Univ Guilan, Fac Engn, Dept Elect Engn, Rasht 4199613776, Iran
关键词
Bisymmetric matrix; fault location; impedance matrix; synchronized measurements; untransposed transmission line; ALGORITHM;
D O I
10.1109/TPWRD.2017.2650780
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Extra high voltage transmission networks include many untransposed single-circuit overhead lines with horizontal configuration of phase conductors. This paper develops a setting-free fault-location method specific to these types of transmission lines. Utilizing synchronized measurements at line terminals, the proposed method accurately locates faults irrespective of fault type, fault resistance, external network parameters, and faulted-line parameters. As such, fault location is robust against ambient conditions as well as inherent inaccuracy of line parameters. The bisymmetry of the impedance matrix of the line is utilized to obtain a closed-form solution for fault location on short transmission lines. For long transmission lines, shunt capacitance of the line is taken into account to obtain an accurate closed-form estimation for fault location. Electromagnetic transient simulation in PSCAD/EMTDC environment validates the accuracy of the proposed fault-location method for a long untransposed 400-kV transmission line. The obtained results are also compared with an existing noniterative parameter-free fault-location method to demonstrate salient features of the proposed method.
引用
收藏
页码:1636 / 1644
页数:9
相关论文
共 50 条
  • [11] Fault Location Method for Untransposed Transmission Lines with Derivations
    Di Santo, S. G.
    Pereira, C. E. M.
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [12] Methodology for testing a parameter-free fault locator for transmission lines
    Popov, Marjan
    Parmar, Shreya
    Rietveld, Gert
    Preston, Gary
    Radojevic, Zoran
    Terzija, Vladimir
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 138 : 92 - 98
  • [13] Parameter-Free Fault Location Algorithm for Distribution Network T-Type Transmission Lines
    Wang, Chengbin
    Yun, Zhihao
    ENERGIES, 2019, 12 (08)
  • [14] An Improved Parameter-Free Fault Locator for Untransposed Line With Unsynchronized Terminals
    Kalita, Kaustav
    Anand, Shubham
    Parida, Sanjoy K.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (06) : 5480 - 5483
  • [15] An Enhanced Parameter-Free Fault Locator for Untransposed Line With Unsynchronized Terminals
    Kalita, Kaustav
    Anand, Shubham
    Parida, S. K.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (05) : 3733 - 3736
  • [16] One-end fault location method for untransposed four-circuit transmission lines
    Ngu, E. E.
    Ramar, K.
    Eisa, Amir
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 43 (01) : 660 - 669
  • [17] A novel noniterative single-ended fault location method with distributed parameter model for AC transmission lines
    Duan, Mengzhao
    Liu, Yu
    Lu, Dian
    Pan, Ruiyu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 153
  • [18] Unsynchronized fault location on untransposed transmission lines with fully distributed parameter model considering line parameter uncertainties
    Lu, Dian
    Liu, Yu
    Lu, Dayou
    Wang, Binglin
    Zheng, Xiaodong
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 202
  • [19] A Decision-Tree-Based Method for Fault Classification in Single-Circuit Transmission Lines
    Jamehbozorg, Arash
    Shahrtash, S. Mohammad
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2190 - 2196
  • [20] Transmission Line Parameter-Free Fault Location Results Using Field Data
    Fan, Wen
    Liao, Yuan
    2018 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2018,