Evaluation of connective tissue disease-related interstitial lung disease using ultrasound elastography: a preliminary study

被引:7
作者
Huan, Songya [1 ,2 ]
Guo, Ruiqian [1 ,2 ]
Yuan, Xinhui [3 ]
Tang, Xinyi [1 ,2 ]
Liu, Tao [4 ]
Xie, Qibing [4 ]
Qiu, Li [1 ,2 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Med Ultrasound, 37 Guo Xue Alley, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Natl Clin Res Ctr Geriatr, 37 Guo Xue Alley, Chengdu 610041, Sichuan, Peoples R China
[3] Peoples Hosp Leshan, Dept Med Ultrasound, Leshan, Peoples R China
[4] Sichuan Univ, Dept Rheumatol & Immunol, West China Hosp, Chengdu, Peoples R China
关键词
Connective tissue disease-related interstitial lung disease (CTD-ILD); ultrasound elastography (UE); lung ultrasound; B-line; pleural line; SHEAR-WAVE ELASTOGRAPHY; IDIOPATHIC PULMONARY-FIBROSIS; SYSTEMIC-SCLEROSIS; ULTRASONOGRAPHY; REPRODUCIBILITY; RELIABILITY; SKIN;
D O I
10.21037/qims-21-1205
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Interstitial lung disease (ILD) is a common pulmonary complication of connective tissue disease (CTD), which can lead to shortened survival. This article explores the ability of shear wave elastography (SWE) to assess lung surface elastic properties and to distinguish healthy lungs from diseased lungs with connective tissue disease-related interstitial lung disease (CTD-ILD). We aimed to determine whether SWE can be used to assess the severity of CTD-ILD. Methods: A total of 65 CTD-ILD patients and 60 healthy volunteers were included for the case group and the control group, respectively. All participants underwent lung ultrasound (count of B-line and measurement of pleural line thickness) and SWE [measurement of Young's modulus (Emean) and shear wave velocity (SMV) (Cmean)] examinations at 50 lung sites. All participants also underwent an examination with high-resolution computed tomography (HRCT) and a pulmonary function test (PFT). For SWE assessment, the Q-box was set to its minimum size (1 mm) and manually placed on the pleural line, rather than inside the lung, to measure the stiffness of the lung surface. The intra- and inter-reliability of SWE measurements of healthy controls (HC), the receiver operating characteristic (ROC) curve for SWE for CTD-ILD, and correlations between different assessment methods were analyzed. Results: Excellent intra- and inter-reliability of SWE measurements on the mid-anterior lung site of HCs (correlation coefficient >0.97; P<0.01) were found. The results of the lung ultrasound of case group participants were significantly higher than those of HCs at each site (P<0.001). The SWE results revealed a significant increase in both Emean and Cmean in CTD-ILD patients (P<0.001) compared with HCs at certain sites (P<0.001). The areas under the curve (AUC) of Emean and Cmean for CTD-ILD were 0.646 and 0.647 (P<0.05), respectively, and the cutoff values for Emean and Cmean to distinguish CTD-ILD from healthy lungs were 15.81 kPa and 2.31 m/s, respectively. There was no significant correlation between the SWE measured values and the number of B-lines, or the HRCT and PFT results, respectively (P>0.05). Conclusions: As a noninvasive ultrasound elastography (UE) technique, SWE may provide a novel method to differentiate CTD-ILD-affected lungs and healthy lungs. It is a reliable way to measure the stiffness of a healthy lung surface in the supine position. However, the ability of SWE to evaluate the severity of CTD-ILD may be limited.
引用
收藏
页码:3778 / +
页数:18
相关论文
共 34 条
  • [1] Lung Ultrasonography in the Evaluation of Interstitial Lung Disease in Systemic Connective Tissue Diseases: Criteria and Severity of Pulmonary Fibrosis - Analysis of 52 Patients
    Buda, N.
    Piskunowicz, M.
    Porzezinska, M.
    Kosiak, W.
    Zdrojewski, Z.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2016, 37 (04): : 375 - 381
  • [2] Assessment of Interstitial Lung Disease Using Lung Ultrasound Surface Wave Elastography A Novel Technique With Clinicoradiologic Correlates
    Clay, Ryan
    Bartholmai, Brian J.
    Zhou, Boran
    Karwoski, Ronald
    Peikert, Tobias
    Osborn, Thomas
    Rajagopalan, Srinivasan
    Kalra, Sanjay
    Zhang, Xiaoming
    [J]. JOURNAL OF THORACIC IMAGING, 2019, 34 (05) : 313 - 319
  • [3] CT features of lung disease in patients with systemic sclerosis: Comparison with idiopathic pulmonary fibrosis and nonspecific interstitial pneumonia
    Desai, SR
    Veeraraghavan, S
    Hanser, DM
    Nikolakopolou, A
    Goh, NSL
    Nicholson, AG
    Colby, TV
    Denton, CP
    Black, CM
    Ois, RMD
    Wells, AU
    [J]. RADIOLOGY, 2004, 232 (02) : 560 - 567
  • [4] Development and Assessment of Novel Lung Ultrasound Interpretation Criteria for the Detection of Interstitial Lung Disease in Systemic Sclerosis
    Fairchild, Robert
    Chung, Melody
    Yang, Diana
    Sharpless, Laurel
    Li, Shufeng
    Chung, Lorinda
    [J]. ARTHRITIS CARE & RESEARCH, 2021, 73 (09) : 1338 - 1342
  • [5] Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity
    Ferraioli, Giovanna
    Tinelli, Carmine
    Zicchetti, Mabel
    Above, Elisabetta
    Poma, Gianluigi
    Di Gregorio, Marta
    Filice, Carlo
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3102 - 3106
  • [6] Ferro F, 2018, CLIN EXP RHEUMATOL, V36, pS165
  • [7] Ultrasound lung comets in systemic sclerosis: a chest sonography hallmark of pulmonary interstitial fibrosis
    Gargani, Luna
    Doveri, Marica
    D'Errico, Luigia
    Frassi, Francesca
    Bazzichi, Maria L.
    Delle Sedie, Andrea
    Scali, Maria C.
    Monti, Simonetta
    Mondillo, Sergio
    Bombardieri, Stefano
    Caramella, Davide
    Picano, Eugenio
    [J]. RHEUMATOLOGY, 2009, 48 (11) : 1382 - 1387
  • [8] Utility of a simplified ultrasound assessment to assess interstitial pulmonary fibrosis in connective tissue disorders - preliminary results
    Gutierrez, Marwin
    Salaffi, Fausto
    Carotti, Marina
    Tardella, Marika
    Pineda, Carlos
    Bertolazzi, Chiara
    Bichisecchi, Elisabetta
    Filippucci, Emilio
    Grassi, Walter
    [J]. ARTHRITIS RESEARCH & THERAPY, 2011, 13 (04)
  • [9] Gutsche M, 2012, CURR PULMONOL REP, V1, P224, DOI 10.1007/s13665-012-0028-7
  • [10] Reproducibility and diagnostic performance of shear wave elastography in evaluating breast solid mass
    Hong, Sun
    Woo, Ok Hee
    Shin, Hye Seon
    Hwang, Soon-Young
    Cho, Kyu Ran
    Seo, Bo Kyoung
    [J]. CLINICAL IMAGING, 2017, 44 : 42 - 45