SET-UP ERRORS IN PROSTATE CANCER PATIENTS TREATED WITH IMRT: RESULTS OF A MONOISTITUTIONAL EXPERIENCE.

被引:0
|
作者
Lupattelli, M. [1 ]
Saccia, S. [1 ]
Romagnoli, E. [1 ]
Milletti, A. [1 ]
Pallottini, S. [1 ]
Russo, S. [1 ]
Paglione, F. [1 ]
Tamburi, F. [1 ]
Trinari, S. [1 ]
Cusco, S. [1 ]
Bellavita, R. [1 ]
Aristei, C. [1 ]
机构
[1] Radiat Oncol Perugia, Perugia, Italy
关键词
D O I
10.1016/S0167-8140(11)71500-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1378
引用
收藏
页码:S513 / S513
页数:1
相关论文
共 50 条
  • [21] Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer
    Yang, Fan
    Li, Xinxia
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [22] Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer
    Yang, Fan
    Li, Xinxia
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [23] Systematic set-up errors for IMRT in the head and neck region: effect on dose distribution
    Samuelsson, A
    Mercke, C
    Johansson, KA
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (03) : 303 - 311
  • [24] SYSTEMIC AND RANDOM SET-UP ERRORS IN RADIOTHERAPY OF PROSTATE CANCER USING KV-CBCT.
    Machanova, M.
    Richter, V.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S342 - S342
  • [25] Set-up errors in prostate cancer radiotherapy based on cone-beam computed tomography.
    Trignani, M.
    Caponigro, G.
    Di Biase, M.
    Bagala, P.
    Falco, M. D.
    Vinciguerra, A.
    Augurio, A.
    Di Tommaso, M.
    Caravatta, L.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S723 - S723
  • [26] Set-up of a camera quality control programme in six departments: the initial experience.
    Seret, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S411 - S411
  • [27] Set-up errors due to endorectal balloon positioning in intensity modulated radiation therapy for prostate cancer
    Wang, Chun-Wei
    Chong, Fok-Ching
    Lai, Ming-Kuen
    Pu, Yeong-Shiau
    Wu, Jian-Kuen
    Cheng, Jason Chia-Hsien
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 (02) : 177 - 184
  • [28] Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans
    Stapleton, S
    Zavgorodni, S
    Popescu, IA
    Beckham, WA
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (03) : 429 - 439
  • [29] Implementation of Monte Carlo modelled random set-up errors in dynamic IMRT treatment plans
    Stapleton, S
    Zavgorodni, S
    Popescu, IA
    Beckham, W
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S88 - S88
  • [30] Evaluation of set-up errors and estimation of set-up margin during external beam radiation therapy of prostate cancer using electronic portal imaging device (EPID)
    Khoramian, Daryoush
    Sistani, Soroush
    Farhood, Bagher
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (04) : 493 - 500