High-Energy X-Ray Imaging Applied to Non Destructive Characterization of Large Nuclear Waste Drums

被引:0
作者
Estre, Nicolas [1 ]
Eck, Daniel [1 ]
Pettier, Jean-Luc [1 ]
Payan, Emmanuel [1 ]
Roure, Christophe [1 ]
Simon, Eric [1 ]
机构
[1] CEN Cadarache, DEN Nucl Measurement Lab, F-13108 St Paul Les Durance, France
来源
2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA) | 2013年
关键词
High-Energy Imaging; nuclear waste drums; linear accelerators; radiography; tomography; scintillators; CdTe; COMPUTED-TOMOGRAPHY; CT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As part of its R&D programs on non-destructive testing of nuclear waste drums, CEA is commissioning an irradiation cell named CINPHONIE, at Cadarache. This cell allows high-energy imaging (radiography and tomography) on large volumes (up to 5 m 3) and heavy weights (up to 5 tons). A demonstrator has been finalized, based on existing components. The X-ray source is a 9 MeV LINAC which produces Bremsstrahlung X-rays (up to 23 Gy/min at 1 meter in the beam axis). The mechanical bench is digitally controlled on three axes (translation, rotation, elevation) and can handle objects up to 2 t. This bench performs trajectories necessary for acquisition of projections (sinograms) according to different geometries: Translation-Rotation, Fan-Beam and Cone-Beam. Two detection systems both developed by CEA-Leti are available. The first one is a large GADOX scintillating screen (800x600 mm(2)) coupled to a low-noise pixelated camera. The second one is a multi-CdTe semiconductor detector, offering measurements up to 5 decades of attenuation (equivalent to 25 cm of lead or 180 cm of standard concrete). At the end of the acquisition, a Filtered Back Projection-based algorithm is performed. Then, a density slice (fan-beam tomography) or a density volume (cone-beam tomography or helical tomography) is produced and used to examine the waste. Characterization of LINAC, associated detectors as well as the full acquisition chain, are presented. Experimental performances on phantoms and real drum are discussed and expected limits on defect detectability are evaluated by simulation. The final system, designed to handle objects up to 5 tons is then presented.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] High-energy X-ray applications: current status and new opportunities
    Jung, Dubravka Sisak
    Donath, Tilman
    Magdysyuk, Oxana
    Bednarcik, Jozef
    [J]. POWDER DIFFRACTION, 2017, 32 : S22 - S27
  • [22] Pixellated Cd(Zn)Te high-energy X-ray instrument
    Seller, P.
    Bell, S.
    Cernik, R. J.
    Christodoulou, C.
    Egan, C. K.
    Gaskin, J. A.
    Jacques, S.
    Pani, S.
    Ramsey, B. D.
    Reid, C.
    Sellin, P. J.
    Scuffham, J. W.
    Speller, R. D.
    Wilson, M. D.
    Veale, M. C.
    [J]. JOURNAL OF INSTRUMENTATION, 2011, 6
  • [23] A method for high-energy, low-dose mammography using edge illumination x-ray phase-contrast imaging
    Diemoz, Paul C.
    Bravin, Alberto
    Sztrokay-Gaul, Aniko
    Ruat, Marie
    Grandl, Susanne
    Mayr, Doris
    Auweter, Sigrid
    Mittone, Alberto
    Brun, Emmanuel
    Ponchut, Cyril
    Reiser, Maximilian F.
    Coan, Paola
    Olivo, Alessandro
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (24) : 8750 - 8761
  • [24] Discrimination of disposal-restricted materials in waste containers by nondestructive testing and image analysis with high-energy X-ray computed tomography
    Murakami, Masashi
    Yoshida, Yukihiko
    Nango, Nobuhito
    Kubota, Shogo
    Kurosawa, Takuya
    Sasaki, Toshiki
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2025,
  • [25] Imaging of high energy nanosecond X-ray pulse accelerators
    Smith, G. W.
    [J]. IMAGING SCIENCE JOURNAL, 2009, 57 (06) : 344 - 351
  • [26] A new X-ray backscatter imaging technique for non-destructive testing of aerospace materials
    Kolkoori, Sanjeevareddy
    Wrobel, Norma
    Zscherpel, Uwe
    Ewert, Uwe
    [J]. NDT & E INTERNATIONAL, 2015, 70 : 41 - 52
  • [27] Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging
    Wong, Molly Donovan
    Yan, Aimin
    Ghani, Muhammad
    Li, Yuhua
    Fajardo, Laurie
    Wu, Xizeng
    Liu, Hong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09) : N37 - N48
  • [28] Non-destructive study of fruits using grating-based X-ray imaging
    Wang, Sheng-Xiang
    Hu, Ren-Fang
    Gao, Kun
    Wali, Faiz
    Zan, Gui-Bin
    Wang, Da-Jiang
    Pan, Zhi-Yun
    Wei, Shi-Qiang
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (02)
  • [29] Advanced Non-Destructive Ocular Visualization Methods by Improved X-Ray Imaging Techniques
    Enders, Christian
    Braig, Eva-Maria
    Scherer, Kai
    Werner, Jens U.
    Lang, Gerhard K.
    Lang, Gabriele E.
    Pfeiffer, Franz
    Noel, Peter
    Rummeny, Ernst
    Herzen, Julia
    [J]. PLOS ONE, 2017, 12 (01):
  • [30] Application of X-Ray CT for Non-destructive Characterization of Graphite Fuel-Tube
    A. K. Agrawal
    P. S. Sarkar
    Y. S. Kashyap
    B. Singh
    A. Sharma
    R. Kumar
    A. Sinha
    [J]. Journal of Nondestructive Evaluation, 2016, 35