Performance Assessment of Motion Tracking Methods in Ultrasound-based Shear Wave Elastography

被引:0
作者
He, Tingting [1 ]
Peng, Bo [1 ]
Chen, Pengcheng [1 ]
Jiang, Jingfeng [2 ]
机构
[1] Southwest Petr Univ, Sch Comp Sci, Chengdu, Peoples R China
[2] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49931 USA
来源
2020 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC) | 2020年
关键词
ultrasound elastography; shear wave elastography; performance assessment; motion tracking; acoustic radiation force; 1 BASIC PRINCIPLES; DISPLACEMENT ESTIMATION; SIMULATION PLATFORM; CLINICAL-USE; RECOMMENDATIONS; ELASTICITY; GUIDELINES; ESTIMATOR;
D O I
10.1109/smc42975.2020.9283024
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Ultrasound elastography is a modality that is uniquely suited to augment conventional B-mode ultrasound for various clinical applications. Motion tracking plays a critically important role during image formation for ultrasound elastography. In this study, the accuracy of four motion tracking methods tailored for acoustic radiation force-based elastography (e.g. acoustic radiation force imaging, shear wave elastography) is compared. In these elastography methods, external mechanical excitation results in small tissue displacements (i.e. 5-10 micrometers). This paper compares four published motion tracking methods: a quadratic sub-sample estimation method, a coupled sub-sample estimation method, a 2-D spline-based estimator, and a 2-D autocorrelation-based motion estimator. Those four methods are evaluated using computer-simulated and tissue-mimicking phantom data. Based on our preliminary data, we find that the autocorrelation-based method is the preferred estimator without considering the lateral displacement. Overall, the spline-based estimator is superior to the other two competitors when both axial and lateral displacements are estimated. Since the spline-based estimation algorithm is considerably time-intensive, the coupled sub-sample estimation method becomes a practical alternative.
引用
收藏
页码:3643 / 3648
页数:6
相关论文
共 50 条
  • [1] ON PATIENT RELATED FACTORS AND THEIR IMPACT ON ULTRASOUND-BASED SHEAR WAVE ELASTOGRAPHY OF THE LIVER
    Byenfeldt, Marie
    Elvin, Anders
    Fransson, Per
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (08) : 1606 - 1615
  • [2] ULTRASOUND-BASED SHEAR WAVE ELASTOGRAPHY IN THE ASSESSMENT OF PATIENTS WITH DIABETIC KIDNEY DISEASE
    Bob, Flaviu
    Grosu, Iulia
    Sporea, Ioan
    Bota, Simona
    Popescu, Alina
    Sima, Alexandra
    Sirli, Roxana
    Petrica, Ligia
    Timar, Romulus
    Schiller, Adalbert
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10) : 2159 - 2166
  • [3] Noninvasive Assessment of Liver Fibrosis Using Ultrasound-Based Shear Wave Measurement and Comparison to Magnetic Resonance Elastography
    Zhao, Heng
    Chen, Jun
    Meixner, Duane D.
    Xie, Hua
    Shamdasani, Vijay
    Zhou, Shiwei
    Robert, Jean-Luc
    Urban, Matthew W.
    Sanchez, William
    Callstrom, Matthew R.
    Ehman, Richard L.
    Greenleaf, James F.
    Chen, Shigao
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (09) : 1597 - 1604
  • [4] Ultrasound-based liver elastography in the assessment of fibrosis
    Fang, C.
    Lim, A.
    Sidhu, P. S.
    CLINICAL RADIOLOGY, 2020, 75 (11) : 822 - 831
  • [5] Neural Network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility
    Peng, Bo
    Xian, Yuhong
    Zhang, Quan
    Jiang, Jingfeng
    ULTRASONIC IMAGING, 2020, 42 (02) : 74 - 91
  • [6] Assessment of ultrasound shear wave elastography: An animal ex-vivo study
    Wang, Xiuming
    Zhu, Jiaan
    Liu, Yiqun
    Li, Wenxue
    Chen, Si
    Zhang, Huabin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (04):
  • [7] Endoscopic Ultrasound-based Shear Wave Elastography for Detection of Advanced Liver Disease
    Abimansour, Jad
    Chin, Jerry Yung-Lun
    Kaur, Jyotroop
    Vargas, Eric J.
    Abu Dayyeh, Barham K.
    Law, Ryan
    Garimella, Vishal
    Levy, Michael J.
    Storm, Andrew C.
    Dierkhising, Ross
    Allen, Alina
    Venkatesh, Sudhakar
    Chandrasekhara, Vinay
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2025, 59 (03) : 256 - 261
  • [8] Comparison of Shear Velocity Dispersion in Viscoelastic Phantoms Measured by Ultrasound-based Shear Wave Elastography and Magnetic Resonance Elastography
    Urban, Matthew W.
    Chen, Jun
    Ehman, Richard L.
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [9] Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography
    Paul, Shashi B.
    Das, Prasenjit
    Mahanta, Mousumi
    Sreenivas, Vishnubhatla
    Kedia, Saurabh
    Kalra, Nancy
    Kaur, Harpreet
    Vijayvargiya, Maneesh
    Ghosh, Shouriyo
    Gamanagatti, Shivanand R.
    Shalimar
    Gupta, Siddhartha Dutta
    Acharya, Subrat K.
    ABDOMINAL RADIOLOGY, 2017, 42 (12) : 2864 - 2873
  • [10] Muscle Ultrasound Shear Wave Elastography as a Non-Invasive Biomarker in Myotonia
    Kronlage, Cornelius
    Grimm, Alexander
    Romano, Alyssa
    Stahl, Jan-Hendrik
    Martin, Pascal
    Winter, Natalie
    Marquetand, Justus
    DIAGNOSTICS, 2021, 11 (02)