Adaptive Radiotherapy of Head and Neck Cancer

被引:154
作者
Castadot, Pierre [1 ]
Lee, John A. [1 ]
Geets, Xavier [1 ]
Gregoire, Vincent [1 ]
机构
[1] Catholic Univ Louvain, Dept Radiat Oncol, Ctr Mol Imaging & Expt Radiotherapy, St Luc Univ Hosp, Brussels, Belgium
关键词
INTENSITY-MODULATED RADIOTHERAPY; CONE-BEAM CT; IMAGE-GUIDED RADIOTHERAPY; MEGAVOLTAGE COMPUTED-TOMOGRAPHY; TARGET VOLUME DELINEATION; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; NASOPHARYNGEAL CANCER; HELICAL TOMOTHERAPY; ANATOMIC CHANGES;
D O I
10.1016/j.semradonc.2009.11.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiation therapy (IMRT) in head and neck (H&N) cancer has the capability to generate steep dose gradients, leading to an improved therapeutic index. IMRT plans are typically based on a pretreatment computed tomography scan that provides a snapshot of the patient's anatomy. Nevertheless, interfractional patient variations may occur because of setup error and anatomical modifications. Therefore, the accuracy of IMRT delivery for H&N cancer may be compromised during the treatment course, potentially affecting the therapeutic index. In this framework, adaptive radiotherapy is a potential solution, which consists of "the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy." Adaptive radiotherapy has brought an additional dimension to the management of patients with H&N cancer and has the potential to counteract the effects of positioning errors and anatomical changes. This article reviews the causes and discusses potential solutions to circumvent the discrepancies between the planned dose and the actual dose received by patients treated for H&N malignancies. © 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:84 / 93
页数:10
相关论文
共 61 条
[51]   Set-up improvement in head and neck radiotherapy using a 3D off-line EPID-based correction protocol and a customised head and neck support [J].
van Lin, ENJT ;
van der Vight, L ;
Huizenga, H ;
Kaanders, JHAM ;
Visser, AG .
RADIOTHERAPY AND ONCOLOGY, 2003, 68 (02) :137-148
[52]   The clinical feasibility and effect of online cone beam computer tomography-guided intensity-modulated radiotherapy for nasopharyngeal cancer [J].
Wang, Jin ;
Bai, Sen ;
Chen, Nianyong ;
Xu, Feng ;
Jiang, Xiaoqin ;
Li, Yan ;
Xu, Qingfeng ;
Shen, Yali ;
Zhang, Hong ;
Gong, Youling ;
Zhong, Renming ;
Jiang, Qingfeng .
RADIOTHERAPY AND ONCOLOGY, 2009, 90 (02) :221-227
[53]   Re-optimization in adaptive radiotherapy [J].
Wu, C ;
Jeraj, R ;
Olivera, GH ;
Mackie, TR .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (17) :3181-3195
[54]   Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy [J].
Xing, L ;
Lin, ZX ;
Donaldson, SS ;
Le, QT ;
Tate, D ;
Goffinet, DR ;
Wolden, S ;
Ma, LJ ;
Boyer, AL .
RADIOTHERAPY AND ONCOLOGY, 2000, 56 (01) :97-108
[55]   Computational challenges for image-guided radiation therapy: Framework and current research [J].
Xing, Lei ;
Siebers, Jeffrey ;
Keall, Paul .
SEMINARS IN RADIATION ONCOLOGY, 2007, 17 (04) :245-257
[56]   Adaptive radiation therapy [J].
Yan, D ;
Vicini, F ;
Wong, J ;
Martinez, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :123-132
[57]   Computed tomography guided management of interfractional patient variation [J].
Yan, D ;
Lockman, D ;
Martinez, A ;
Wong, J ;
Brabbins, D ;
Vicini, F ;
Liang, J ;
Kestin, L .
SEMINARS IN RADIATION ONCOLOGY, 2005, 15 (03) :168-179
[58]   Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors [J].
Yan, D ;
Wong, J ;
Vicini, F ;
Michalski, J ;
Pan, C ;
Frazier, A ;
Horwitz, E ;
Martinez, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (01) :197-206
[59]   The use of adaptive radiation therapy to reduce setup error: A prospective clinical study [J].
Yan, D ;
Ziaja, E ;
Jaffray, D ;
Wong, J ;
Brabbins, D ;
Vicini, F ;
Martinez, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03) :715-720
[60]   Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation [J].
Yang, Yong ;
Schreibmann, Eduard ;
Li, Tianfang ;
Wang, Chuang ;
Xing, Lei .