High-throughput flow cytometry: Validation in microvolume bioassays

被引:44
|
作者
Ramirez, S [1 ]
Aiken, CT [1 ]
Andrzejewski, B [1 ]
Sklar, LA [1 ]
Edwards, BS [1 ]
机构
[1] Univ New Mexico, Hlth Sci Ctr, Dept Pathol, Canc Res & Treatment Ctr, Albuquerque, NM 87131 USA
关键词
flow cytometry; automation; drug discovery; biomolecular screening; SELECTIN GLYCOPROTEIN LIGAND-1; P-SELECTIN; DRUG DISCOVERY;
D O I
10.1002/cyto.a.10035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: We recently reported an automated sample handling system, designated HyperCyt, by which samples are aspirated from microplate wells and delivered to the flow cytometer for analysis at rates approaching 100 samples per minute. In this approach, an autosampler and peristaltic pump introduce samples into a tubing line that directly connects to the flow cytometer. Air bubbles are inserted between samples to prevent sample dispersion. In the present work, we compare results of HyperCyt with those of conventional manual flow cytometric analysis in representative flow cytometric bioassays and describe a cell suspension method in which HyperCyt exploits the use of microvolume wells. Methods: Human eosinophils and neutrophils were treated with trypsin to generate a wide (>25-fold) range of membrane P-selectin glycoprotein ligand-1 (PSGL-1) expression and then stained with fluorescent anti-PSGL-1 antibodies. Human peripheral blood mononuclear cells were stained with fluorescein isothiocyanate- and phycoerythrin-conjugated monoclonal antibodies for multiparameter immunophenotype analysis. U937 cells labeled with PKH62GL were used to assess cell settling in microplate wells. Results: Differences in PSGL-1 expression levels were detected by HyperCyt autosampling of leukocytes from 96-well plates at an analysis rate of approximately 1.5 s/well. Hyper-Cyt measurements linearly correlated with parallel manual measurements (r(2) = 0.98). Lymphocyte subpopulations were accurately distinguished and reproducibly quantified in multiparameter immunophenotyping assays performed over a range of HyperCyt analysis rates (1.4-5.5 s/sample). When assay volumes were reduced to 10 mul/well in 60-well Terasaki plates, cells could be maintained in uniform suspension for up to 30 min by periodically inverting plates on a rotating carousel before HyperCyt analysis. HyperCyt analysis of five fluorescence-level Cyto-Plex beads sampled from Temsaki plate microwells at 2.5 s/well produced highly reproducible results over a wide range of input bead concentrations (from 7 X 10(5) to 20 X 10(6) beads/ml) that linearly correlated with manual analysis results. Conclusions: The HyperCyt autosampling system enabled a 10-fold or greater increase in sample thoughput compared with conventional manual flow cytometric sample analysis, with comparable analysis results. Assays were performed efficiently in 10-mul volumes to enable significant reagent cost savings, use of quantity-limited reagents at otherwise prohibitive concentrations, and maintenance of uniform suspensions of cells for prolonged periods. Cytometry Part A 53A:55-65, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 50 条
  • [21] Discovery of Regulators of Receptor Internalization with High-Throughput Flow Cytometry
    Wu, Yang
    Tapia, Phillip H.
    Fisher, Gregory W.
    Simons, Peter C.
    Strouse, J. Jacob
    Foutz, Terry
    Waggoner, Alan S.
    Jarvik, Jonathan
    Sklar, Larry A.
    MOLECULAR PHARMACOLOGY, 2012, 82 (04) : 645 - 657
  • [22] High-Throughput Flow Cytometry Data Normalization for Clinical Trials
    Finak, Greg
    Jiang, Wenxin
    Krouse, Kevin
    Wei, Chungwen
    Sanz, Ignacio
    Phippard, Deborah
    Asare, Adam
    De Rosa, Stephen C.
    Self, Steve
    Gottardo, Raphael
    CYTOMETRY PART A, 2014, 85 (03) : 277 - 286
  • [23] Imaging Flow Cytometry for High-Throughput Phenotyping of Synthetic Cells
    Godino, Elisa
    Sierra, Ana Maria Restrepo
    Danelon, Christophe
    ACS SYNTHETIC BIOLOGY, 2023, 12 (07): : 2015 - 2028
  • [24] High-throughput autofluorescence flow cytometry of breast cancer metabolism
    Shah, Amy T.
    Cannon, Taylor M.
    Higginbotham, Jim N.
    Skala, Melissa C.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [25] Emerging platforms for high-throughput enzymatic bioassays
    Shao, Fangchi
    Lee, Pei-Wei
    Li, Hui
    Hsieh, Kuangwen
    Wang, Tza-Huei
    TRENDS IN BIOTECHNOLOGY, 2023, 41 (01) : 120 - 133
  • [26] ASPIRATOR GUN FOR HIGH-THROUGHPUT MOSQUITO BIOASSAYS
    Aldridge, Robert L.
    Wynn, W. Wayne
    Britch, Seth C.
    Linthicum, Kenneth J.
    JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION, 2012, 28 (01) : 65 - 68
  • [27] High-throughput and high-resolution flow cytometry in molded microfluidic devices
    Simonnet, Claire
    Groisman, Alex
    ANALYTICAL CHEMISTRY, 2006, 78 (16) : 5653 - 5663
  • [28] High-throughput label-free molecular fingerprinting flow cytometry
    Hiramatsu, Kotaro
    Ideguchi, Takuro
    Yonamine, Yusuke
    Lee, SangWook
    Luo, Yizhi
    Hashimoto, Kazuki
    Ito, Takuro
    Hase, Misa
    Park, Jee-Woong
    Kasai, Yusuke
    Sakuma, Shinya
    Hayakawa, Takeshi
    Arai, Fumihito
    Hoshino, Yu
    Goda, Keisuke
    SCIENCE ADVANCES, 2019, 5 (01):
  • [29] High-Throughput Analysis of Clinical Flow Cytometry Data by Automated Gating
    Lee, Hunjoong
    Sun, Yongliang
    Patti-Diaz, Lisa
    Hedrick, Michael
    Ehrhardt, Anka G.
    BIOINFORMATICS AND BIOLOGY INSIGHTS, 2019, 13
  • [30] High-throughput parallel 3D imaging flow cytometry
    Ugawa, Masashi
    Ota, Sadao
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES XXI, 2023, 12383