High-throughput flow cytometry: Validation in microvolume bioassays

被引:44
作者
Ramirez, S [1 ]
Aiken, CT [1 ]
Andrzejewski, B [1 ]
Sklar, LA [1 ]
Edwards, BS [1 ]
机构
[1] Univ New Mexico, Hlth Sci Ctr, Dept Pathol, Canc Res & Treatment Ctr, Albuquerque, NM 87131 USA
关键词
flow cytometry; automation; drug discovery; biomolecular screening; SELECTIN GLYCOPROTEIN LIGAND-1; P-SELECTIN; DRUG DISCOVERY;
D O I
10.1002/cyto.a.10035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: We recently reported an automated sample handling system, designated HyperCyt, by which samples are aspirated from microplate wells and delivered to the flow cytometer for analysis at rates approaching 100 samples per minute. In this approach, an autosampler and peristaltic pump introduce samples into a tubing line that directly connects to the flow cytometer. Air bubbles are inserted between samples to prevent sample dispersion. In the present work, we compare results of HyperCyt with those of conventional manual flow cytometric analysis in representative flow cytometric bioassays and describe a cell suspension method in which HyperCyt exploits the use of microvolume wells. Methods: Human eosinophils and neutrophils were treated with trypsin to generate a wide (>25-fold) range of membrane P-selectin glycoprotein ligand-1 (PSGL-1) expression and then stained with fluorescent anti-PSGL-1 antibodies. Human peripheral blood mononuclear cells were stained with fluorescein isothiocyanate- and phycoerythrin-conjugated monoclonal antibodies for multiparameter immunophenotype analysis. U937 cells labeled with PKH62GL were used to assess cell settling in microplate wells. Results: Differences in PSGL-1 expression levels were detected by HyperCyt autosampling of leukocytes from 96-well plates at an analysis rate of approximately 1.5 s/well. Hyper-Cyt measurements linearly correlated with parallel manual measurements (r(2) = 0.98). Lymphocyte subpopulations were accurately distinguished and reproducibly quantified in multiparameter immunophenotyping assays performed over a range of HyperCyt analysis rates (1.4-5.5 s/sample). When assay volumes were reduced to 10 mul/well in 60-well Terasaki plates, cells could be maintained in uniform suspension for up to 30 min by periodically inverting plates on a rotating carousel before HyperCyt analysis. HyperCyt analysis of five fluorescence-level Cyto-Plex beads sampled from Temsaki plate microwells at 2.5 s/well produced highly reproducible results over a wide range of input bead concentrations (from 7 X 10(5) to 20 X 10(6) beads/ml) that linearly correlated with manual analysis results. Conclusions: The HyperCyt autosampling system enabled a 10-fold or greater increase in sample thoughput compared with conventional manual flow cytometric sample analysis, with comparable analysis results. Assays were performed efficiently in 10-mul volumes to enable significant reagent cost savings, use of quantity-limited reagents at otherwise prohibitive concentrations, and maintenance of uniform suspensions of cells for prolonged periods. Cytometry Part A 53A:55-65, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 50 条
  • [21] A high-throughput 3-parameter flow cytometry-based cell death assay
    Buenz, Eric J.
    Limburg, Paul J.
    Howe, Charles L.
    CYTOMETRY PART A, 2007, 71A (03) : 170 - 173
  • [22] A Fully Automated High-Throughput Flow Cytometry Screening System Enabling Phenotypic Drug Discovery
    Joslin, John
    Gilligan, James
    Anderson, Paul
    Garcia, Catherine
    Sharif, Orzala
    Hampton, Janice
    Cohen, Steven
    King, Miranda
    Zhou, Bin
    Jiang, Shumei
    Trussell, Christopher
    Dunn, Robert
    Fathman, John W.
    Snead, Jennifer L.
    Boitano, Anthony E.
    Nguyen, Tommy
    Conner, Michael
    Cooke, Mike
    Harris, Jennifer
    Ainscow, Ed
    Zhou, Yingyao
    Shaw, Chris
    Sipes, Dan
    Mainquist, James
    Lesley, Scott
    SLAS DISCOVERY, 2018, 23 (07) : 697 - 707
  • [23] A multifunctional androgen receptor screening assay using the high-throughput HyperCyt® flow cytometry system
    Dennis, Megan K.
    Bowles, Harmony J. C.
    MacKenzie, Debra A.
    Burchiel, Scott W.
    Edwards, Bruce S.
    Sldar, Larry A.
    Prossnitz, Eric R.
    Thompson, Todd A.
    CYTOMETRY PART A, 2008, 73A (05) : 390 - 399
  • [24] High-Throughput Measurement of Small-Molecule Enantiopurity by Using Flow Cytometry
    Tan, Zhesen
    Heemstra, Jennifer M.
    CHEMBIOCHEM, 2018, 19 (17) : 1853 - 1857
  • [25] Application of flow cytometry for rapid, high-throughput, multiparametric analysis of environmental microbiomes
    Priyadarsini, Madhumita
    Kushwaha, Jeetesh
    Pandey, Kailash Pati
    Rani, Jyoti
    Dhoble, Abhishek S.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2023, 214
  • [26] Use of flow cytometry for high-throughput cell population estimates in brain tissue
    Young, Nicole A.
    Flaherty, David K.
    Airey, David C.
    Varlan, Peter
    Aworunse, Feyi
    Kaas, Jon H.
    Collins, Christine E.
    FRONTIERS IN NEUROANATOMY, 2012, 6
  • [27] High-throughput screening of single-chain antibodies using multiplexed flow cytometry
    Ayriss, Joanne
    Woods, Travis
    Bradbury, Andrew
    Pavlik, Peter
    JOURNAL OF PROTEOME RESEARCH, 2007, 6 (03) : 1072 - 1082
  • [28] High-throughput Flow Cytometry Assay to Investigate TDP43 Splicing Function
    Schmidt, H. Broder
    Rohatgi, Rajat
    BIO-PROTOCOL, 2020, 10 (08):
  • [29] Flow cytometry-based high-throughput screening of synthetic peptides for palladium adsorption
    Tan, Ling
    Liu, Meizi
    Wang, Lixian
    Zhao, Guoping
    Zhang, Yanfei
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 461
  • [30] Applications of Biophysics in High-Throughput Screening Hit Validation
    Genick, Christine Clougherty
    Barlier, Danielle
    Monna, Dominique
    Brunner, Reto
    Be, Celine
    Scheufler, Clemens
    Ottl, Johannes
    JOURNAL OF BIOMOLECULAR SCREENING, 2014, 19 (05) : 707 - 714