High-throughput flow cytometry: Validation in microvolume bioassays

被引:44
|
作者
Ramirez, S [1 ]
Aiken, CT [1 ]
Andrzejewski, B [1 ]
Sklar, LA [1 ]
Edwards, BS [1 ]
机构
[1] Univ New Mexico, Hlth Sci Ctr, Dept Pathol, Canc Res & Treatment Ctr, Albuquerque, NM 87131 USA
关键词
flow cytometry; automation; drug discovery; biomolecular screening; SELECTIN GLYCOPROTEIN LIGAND-1; P-SELECTIN; DRUG DISCOVERY;
D O I
10.1002/cyto.a.10035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: We recently reported an automated sample handling system, designated HyperCyt, by which samples are aspirated from microplate wells and delivered to the flow cytometer for analysis at rates approaching 100 samples per minute. In this approach, an autosampler and peristaltic pump introduce samples into a tubing line that directly connects to the flow cytometer. Air bubbles are inserted between samples to prevent sample dispersion. In the present work, we compare results of HyperCyt with those of conventional manual flow cytometric analysis in representative flow cytometric bioassays and describe a cell suspension method in which HyperCyt exploits the use of microvolume wells. Methods: Human eosinophils and neutrophils were treated with trypsin to generate a wide (>25-fold) range of membrane P-selectin glycoprotein ligand-1 (PSGL-1) expression and then stained with fluorescent anti-PSGL-1 antibodies. Human peripheral blood mononuclear cells were stained with fluorescein isothiocyanate- and phycoerythrin-conjugated monoclonal antibodies for multiparameter immunophenotype analysis. U937 cells labeled with PKH62GL were used to assess cell settling in microplate wells. Results: Differences in PSGL-1 expression levels were detected by HyperCyt autosampling of leukocytes from 96-well plates at an analysis rate of approximately 1.5 s/well. Hyper-Cyt measurements linearly correlated with parallel manual measurements (r(2) = 0.98). Lymphocyte subpopulations were accurately distinguished and reproducibly quantified in multiparameter immunophenotyping assays performed over a range of HyperCyt analysis rates (1.4-5.5 s/sample). When assay volumes were reduced to 10 mul/well in 60-well Terasaki plates, cells could be maintained in uniform suspension for up to 30 min by periodically inverting plates on a rotating carousel before HyperCyt analysis. HyperCyt analysis of five fluorescence-level Cyto-Plex beads sampled from Temsaki plate microwells at 2.5 s/well produced highly reproducible results over a wide range of input bead concentrations (from 7 X 10(5) to 20 X 10(6) beads/ml) that linearly correlated with manual analysis results. Conclusions: The HyperCyt autosampling system enabled a 10-fold or greater increase in sample thoughput compared with conventional manual flow cytometric sample analysis, with comparable analysis results. Assays were performed efficiently in 10-mul volumes to enable significant reagent cost savings, use of quantity-limited reagents at otherwise prohibitive concentrations, and maintenance of uniform suspensions of cells for prolonged periods. Cytometry Part A 53A:55-65, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 50 条
  • [1] High-Throughput Flow Cytometry
    Robinson, J. Paul
    Patsekin, Valery
    Rajwa, Bartek
    Davisson, V. Jo
    Li, Nianyu
    Narayanan, Padmakumar
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2011, 31 (08): : 20 - +
  • [2] Viscoelasticity as a Biomarker for High-Throughput Flow Cytometry
    Sawetzki, Tobias
    Eggleton, Charles D.
    Desai, Sanjay A.
    Marr, David W. M.
    BIOPHYSICAL JOURNAL, 2013, 105 (10) : 2281 - 2288
  • [3] High-Throughput Raman Flow Cytometry and Beyond
    Gala de Pablo, Julia
    Lindley, Matthew
    Hiramatsu, Kotaro
    Goda, Keisuke
    ACCOUNTS OF CHEMICAL RESEARCH, 2021, 54 (09) : 2132 - 2143
  • [4] High-Throughput Flow Cytometry in Drug Discovery
    Ding, Mei
    Edwards, Bruce S.
    SLAS DISCOVERY, 2018, 23 (07) : 599 - 602
  • [5] High-throughput flow cytometry for drug discovery
    Edwards, Bruce S.
    Young, Susan M.
    Saunders, Matthew J.
    Bologa, Cristian
    Oprea, Tudor I.
    Ye, Richard D.
    Prossnitz, Eric R.
    Graves, Steven W.
    Sklar, Larry A.
    EXPERT OPINION ON DRUG DISCOVERY, 2007, 2 (05) : 685 - 696
  • [6] A Scalable Pipeline for High-Throughput Flow Cytometry
    Wilson, Aaron C.
    Moutsatsos, Ioannis K.
    Yu, Gary
    Pineda, Javier J.
    Feng, Yan
    Auld, Douglas S.
    SLAS DISCOVERY, 2018, 23 (07) : 708 - 718
  • [7] High-throughput microfluidic imaging flow cytometry
    Stavrakis, Stavros
    Holzner, Gregor
    Choo, Jaebum
    DeMello, Andrew
    CURRENT OPINION IN BIOTECHNOLOGY, 2019, 55 : 36 - 43
  • [8] High-throughput tri-colour flow cytometry technique to assess Plasmodium falciparum parasitaemia in bioassays
    Tiendrebeogo, Regis W.
    Adu, Bright
    Singh, Susheel K.
    Dodoo, Daniel
    Dziegiel, Morten H.
    Mordmueller, Benjamin
    Nebie, Issa
    Sirima, Sodiomon B.
    Christiansen, Michael
    Theisen, Michael
    MALARIA JOURNAL, 2014, 13
  • [9] High-throughput tri-colour flow cytometry technique to assess Plasmodium falciparum parasitaemia in bioassays
    Regis W Tiendrebeogo
    Bright Adu
    Susheel K Singh
    Daniel Dodoo
    Morten H Dziegiel
    Benjamin Mordmüller
    Issa Nébié
    Sodiomon B Sirima
    Michael Christiansen
    Michael Theisen
    Malaria Journal, 13
  • [10] Flow cytometry for high-throughput, high-content screening
    Edwards, BS
    Oprea, T
    Prossnitz, ER
    Sklar, LA
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2004, 8 (04) : 392 - 398