Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin

被引:10
作者
Goncalves, Lucelia Lemes [1 ]
Da Silva, Tania Mara [1 ]
Prakki, Anuradha [2 ]
Barcellos, Daphne Camara [3 ]
Caneppele, Taciana Marco Ferraz [4 ]
De Oliveira, Hueder Paulo Moises [5 ]
Goncalves, Sergio Eduardo de Paiva [4 ,6 ]
机构
[1] Anhanguera Fac Sao Jose Campos, Sao Jose Dos Campos, SP, Brazil
[2] Univ Toronto, Fac Dent, Dept Clin Sci Restorat, Toronto, ON, Canada
[3] Univ Fed Espirito Santo, Dept Prosthodont, Vitoria, ES, Brazil
[4] UNESP Univ Estadual Paulista, Inst Sci & Technol, Dept Restorat Dent, Sao Jose Dos Campos, SP, Brazil
[5] Fed Univ ABC, Ctr Nat & Human Sci, Santo Andre, SP, Brazil
[6] UNESP Univ Estadual Paulista, Inst Ciencia & Tecnol, Dept Odontol Restauradora, Campus Sao Jose Campos, BR-12245000 Sao Jose Dos Campos, SP, Brazil
关键词
Dental pulp; Dental bonding; Adhesives; SINGLE-STEP; PERMEABLE MEMBRANES; STRENGTH; ETCH; SYSTEMS; POLYMERIZATION; PENETRATION; DEGRADATION; TEMPERATURE; INTERFACE;
D O I
10.1007/s10266-021-00633-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the effect of SPP with either fetal bovine serum (FBS) or deionized water (DW) on the bond strength (mu TBS) of a Universal adhesive to dentin, in both etch-and-rinse (ER) and self-etch (SE) modes. The kinematic viscosity (cSt) of FBS and DW was measured at 25 degrees C +/- 0.1 oC. Seventy-two sound human molars were sectioned and randomly divided into three groups according to the SPP conditions: (1) Control (0 cm H2O), (2) SPP (15 cm H2O) with FBS, (3) SPP (15 cm H2O) with DW. Each group was subdivided (n = 10) based on the bonding modes: ER (37% phosphoric acid + ScothBond Universal Adhesive) or SE (ScothBond Universal Adhesive). Samples were then submitted to mu TBS. Data were analyzed by Student's t test, two-way ANOVA and Tukey tests (p < 0.05). The cSt results showed that DW (23.59 +/- 0.39) had significantly higher values than FBS (22.33 +/- 0.06). With regard to SPP, the control group (36.1 MPa) had significantly higher values of mu TBS when compared to the SPP using FBS (31.06 MPa) and SPP with DW (26.55 MPa). According to ANOVA, the bonding modes and the interaction of simulated pulpal pressure (SPP) did not statistically influence the results (p < 0.05). The presence of SPP reduced the bond strength of Universal adhesive to dentin. DW during SPP had significantly reduced bonding values when compared to FBS. Bonding strategies were not affected by SPP when evaluated in a short period of time (24 h).
引用
收藏
页码:62 / 69
页数:8
相关论文
共 50 条
[21]   Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure [J].
Silva, T. M. ;
Goncalves, L. L. ;
Fonseca, B. M. ;
Esteves, S. R. M. S. ;
Barcellos, D. C. ;
Damiao, A. J. ;
Goncalves, S. E. P. .
LASERS IN MEDICAL SCIENCE, 2016, 31 (01) :49-56
[22]   Bonding performance of universal adhesives in different etching modes [J].
Wagner, Andrea ;
Wendler, Michael ;
Petschelt, Anselm ;
Belli, Renan ;
Lohbauer, Ulrich .
JOURNAL OF DENTISTRY, 2014, 42 (07) :800-807
[23]   Does the universal adhesive's film thickness affect dentin-bonding effectiveness? [J].
Tang, Chuliang ;
Mercelis, Ben ;
Yoshihara, Kumiko ;
Peumans, Marleen ;
Van Meerbeek, Bart .
CLINICAL ORAL INVESTIGATIONS, 2024, 28 (02)
[24]   The Bonding Performance of a Universal Adhesive to Artificially-created Caries-affected Dentin [J].
Nicoloso, Gabriel Ferreira ;
Antoniazzi, Bruna Feltrin ;
Lenzi, Tathiane Larissa ;
Maxnuck Soares, Fabio Zovico ;
Rocha, Rachel de Oliveira .
JOURNAL OF ADHESIVE DENTISTRY, 2017, 19 (04) :317-321
[25]   Does Bonding Approach Influence the Bond Strength of Universal Adhesive to Dentin of Primary Teeth? [J].
Lenzi, Tathiane Larissa ;
Maxnuck Soares, Fabio Zovico ;
Rocha, Rachel de Oliveira .
JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2017, 41 (03) :214-218
[26]   Microtensile dentin adhesive bond strength under different positive pulpal pressures [J].
Purk, John H. ;
Dusevich, Vladimir ;
Atwood, Jared ;
Spencer, Becca Dawson ;
Kruse, Dustin ;
Webb, Tyler ;
Williams, Angela ;
Tira, Daniel .
AMERICAN JOURNAL OF DENTISTRY, 2009, 22 (06) :357-360
[27]   Comparative Assessment of Different Pre-Treatment Bonding Strategies to Improve the Adhesion of Self-Adhesive Composites to Dentin [J].
Ingles, Magali ;
Cruz, Joana Vasconcelos E. ;
Azul, Ana Mano ;
Polido, Mario ;
Delgado, Antonio H. S. .
POLYMERS, 2022, 14 (19)
[28]   Influence of different etching modes on bond strength and fatigue strength to dentin using universal adhesive systems [J].
Takamizawa, Toshiki ;
Barkmeier, Wayne W. ;
Tsujimoto, Akimasa ;
Berry, Thomas P. ;
Watanabe, Hedehiko ;
Erickson, Robert L. ;
Latta, Mark A. ;
Miyazaki, Masashi .
DENTAL MATERIALS, 2016, 32 (02) :E9-E21
[29]   Effect of Application Deviations on Dentin Sealing of a Universal Adhesive: Permeability and Nanoleakage [J].
Cavalheiro, Alexandre ;
Cruz, Joana ;
Sousa, Bernardo ;
Silva, Ana ;
Eira, Raquel ;
Coito, Catarina ;
Lopes, Manuela .
EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (01) :242-249
[30]   Effect of Extra Hydrophobic Resin Layer on Bonding of Universal Adhesive Systems to Enamel [J].
Soares, J. P. B. ;
Perdigao, J. ;
Chrispim, B. ;
Lopes, G. C. .
OPERATIVE DENTISTRY, 2023, 48 (02) :E48-E59