Moisture transfer resistance method for liquid desiccant dehumidification analysis and optimization

被引:46
|
作者
Chen Lin [1 ]
Chen Qun [1 ]
Li Zhen [1 ]
Guo ZengYuan [1 ]
机构
[1] Tsinghua Univ, Dept Engn Mech, Minist Educ, Key Lab Thermal Sci & Power Engn, Beijing 100084, Peoples R China
来源
CHINESE SCIENCE BULLETIN | 2010年 / 55卷 / 14期
基金
中国博士后科学基金;
关键词
liquid desiccant dehumidification; energy conservation; heat and mass transfer; entransy dissipation; moisture transfer resistance; DECONTAMINATION VENTILATION DESIGNS; PLATE HEAT-EXCHANGER; PERFORMANCE ANALYSIS; AIR; SYSTEM; REGENERATION; ENTRANSY;
D O I
10.1007/s11434-010-0006-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The concepts of entransy, entransy dissipation and transfer resistance are introduced into liquid desiccant dehumidification analysis to reveal the irreversibility and moisture transfer resistance between moist air and liquid desiccant. By analyzing a typical water (vapor) transfer process coupled with heat transfer, we define the concepts of mass entransy of water and its dissipation, derive the expression of moisture transfer resistance (MTR) that reflects the irreversibility of water transfer during dehumidification processes, and also point out the relationship between MTR and dehumidification performance. With these concepts, both adiabatic and internal cooling liquid desiccant dehumidification systems with various operation conditions are analyzed and optimized. It is found that for the adiabatic dehumidification system, increasing the mass transfer coefficient leads to the reduction of MTR, and consequently, the improvement of dehumidification performance. Meanwhile, for the dehumidification system with internal cooling, in order to reduce the MTR and improve the dehumidification performance, pre-cooling should be centralized ahead of the liquid desiccant inlet when the flow rates ratio of air to desiccant is small, whereas, uniform cooling should be applied when the flow rates ratio of air to desiccant is large.
引用
收藏
页码:1445 / 1453
页数:9
相关论文
共 50 条
  • [21] Artificial neural network analysis of liquid desiccant dehumidification system
    Gandhidasan, P.
    Mohandes, M. A.
    ENERGY, 2011, 36 (02) : 1180 - 1186
  • [22] Experimental analysis on chemical dehumidification of air by liquid desiccant and desiccant regeneration in a packed tower
    Longo, GA
    Gasparella, A
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 587 - 591
  • [23] Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis
    Zhang, Qinling
    Liu, Xiaohua
    Zhang, Tao
    Xie, Ying
    ENERGY, 2020, 204
  • [24] Predictions of moisture removal rate and dehumidification effectiveness for structured liquid desiccant air dehumidifier
    Abdul-Wahab, SA
    Zurigat, YH
    Abu-Arabi, MK
    ENERGY, 2004, 29 (01) : 19 - 34
  • [25] Performance analysis of dehumidification rotating wheel using liquid desiccant
    Hamed, AM
    Khalil, A
    Kabeel, AE
    Bassuoni, MM
    Elzahaby, AM
    RENEWABLE ENERGY, 2005, 30 (11) : 1689 - 1712
  • [26] Exergy calculation and analysis of a dehumidification system using liquid desiccant
    Zhang, Lun
    Liu, Xiaohua
    Jiang, Jingjing
    Jiang, Yi
    ENERGY AND BUILDINGS, 2014, 69 : 318 - 328
  • [27] Formaldehyde removal performance analysis of a liquid desiccant dehumidification system
    Fu, Huangxi
    Liu, Xiaohua
    Xie, Ying
    Liu, Jun
    BUILDING AND ENVIRONMENT, 2017, 124 : 283 - 293
  • [28] Ideal efficiency analysis and comparison of condensing and liquid desiccant dehumidification
    Zhang, Lun
    Liu, Xiao-Hua
    Jiang, Yi
    ENERGY AND BUILDINGS, 2012, 49 : 575 - 583
  • [30] Development of a new control method for the dynamic liquid desiccant dehumidification process
    Zhang, Xiaobo
    Xu, Xiangguo
    Ma, Xinyue
    ENERGY AND BUILDINGS, 2022, 269