Double plate osteosynthesis provides better biomechanical stabilization than double tension band technique in distal humerus fractures

被引:1
|
作者
Dogramaci, Yunus [1 ]
Esen, Erdinc [2 ]
Kurklu, Mustafa [3 ]
Kirici, Yalcin [4 ]
Atahan, Ali O. [5 ]
Komurcu, Mahmut [3 ]
机构
[1] Mustafa Kemal Univ, Tip Fak, Ortoped & Travmatol Anabilim Dali, TR-31100 Antakya, Hatay, Turkey
[2] Gazi Univ, Fac Med, Dept Orthoped & Traumatol, Ankara, Turkey
[3] Gulhane Mil Med Acad, Dept Orthoped, Ankara, Turkey
[4] Gulhane Mil Med Acad, Dept Anat, Ankara, Turkey
[5] Mustafa Kemal Univ, Dept Engn, TR-31100 Antakya, Hatay, Turkey
来源
EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY | 2010年 / 21卷 / 01期
关键词
Biomechanics; distal humerus; fractures; osteosynthesis; SURGICAL-TREATMENT; INTRAARTICULAR FRACTURES; INTERNAL-FIXATION; INTERCONDYLAR FRACTURES; ELDERLY-PATIENTS; ADULTS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: In this study we evaluated the stability and effectiveness of the double tension band osteosynthesis technique compared to the double plate osteosynthesis technique used for fixation of distal humerus fractures Materials and methods: The study was performed on two groups. and in each group eight cadaveric, elderly (mean age 70-80) human humeri was used An osteotomy was performed in the supracondylar region using a manual saw The first group (group 1) was fixed with double 3.5 mm reconstruction plates, while the second group (group 2) was fixed with the double tension band technique. using crossing Kirschner wires The osteotomy was designed so that the distal fragment would allow only a single screw per plate The constructs were evaluated using a material testing machine A linear non-cyclic load was applied until the failure of the constructs. The force which produced a 3 mm gap (3 mm gap strength). as detected visually with the aid of operating loupes. and the maximum load prior to failure of the fixation (maximum force) were measured from all tests Results: The mean value for the 3 mm gap strength was 1356 29 +/- 226 97 N for group 1 and 882 63 30521 N for group 2. The mean value of the maximum load strength was 1487.13 +/- 298 N for group 1 and 1232 10762 N for group 2 There were significant differences in 3 mm gap strengths of the two groups (p=0 005) There was also a significant difference in the maximum load between the two groups (p=0 016). Conclusion: Double plate osteosynthesis technique is superior to double tension band osteosynthesis for the fixation of distal humerus fractures.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 29 条
  • [21] Limited open reduction is better for simple-distal tibial shaft fractures than minimally invasive plate osteosynthesis
    Li, Q.
    Zeng, B. F.
    Luo, C. F.
    Song, S.
    Zhang, C. Q.
    Kong, W. Q.
    GENETICS AND MOLECULAR RESEARCH, 2014, 13 (03) : 5361 - 5368
  • [22] Transosseous braided-tape and double-row fixations are better than tension band for avulsion-type greater tuberosity fractures
    Brais, Godefroy
    Menard, Jeremie
    Mutch, Jennifer
    Laflamme, G-Yves
    Petit, Yvan
    Rouleau, Dominique M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (06): : 1007 - 1012
  • [23] Dual plate has better biomechanical stability than hook plate or superior single plate for the fixation of unstable distal clavicle fractures: a finite element analysis
    Huang, Daoqiang
    Hu, Zhiqiang
    Feng, Weili
    Wang, Xiaoping
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (08) : 4805 - 4812
  • [24] Dual plate has better biomechanical stability than hook plate or superior single plate for the fixation of unstable distal clavicle fractures: a finite element analysis
    Daoqiang Huang
    Zhiqiang Hu
    Weili Feng
    Xiaoping Wang
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4805 - 4812
  • [25] Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures
    Hoegel, Florian Wolfgang
    Hoffmann, S.
    Weninger, P.
    Buehren, V.
    Augat, P.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (04): : 933 - 938
  • [26] Less invasive stabilization of complex tibial plateau fractures -: A biomechanical evaluation of a unilateral locked screw plate and double plating
    Gösling, T
    Schandelmaier, P
    Marti, A
    Hufner, T
    Partenheimer, A
    Krettek, C
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 546 - 551
  • [27] New technique for treatment of unstable distal femur fractures by locked double-plating: Case report and biomechanical evaluation
    Jazrawi, LM
    Kummer, FJ
    Simon, JA
    Bai, B
    Hunt, SA
    Egol, KA
    Koval, KJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (01): : 87 - 92
  • [28] Clinical and radiological results of three different techniques for fixation of the olecranon osteotomy in the surgical treatment of distal humerus fractures: A retrospective comparison of plate-screw, tension band and intramedullary nail
    Yildiz, Vahit
    Kose, Ahmet
    Aydin, Ali
    Dincer, Recep
    Baydar, Mehmet
    Ayas, Muhammet Salih
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2021, 55 (05) : 410 - 416
  • [29] Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities
    Schuster, Ivo
    Korner, Jan
    Arzdorf, Michael
    Schwieger, Karsten
    Diederichs, Gerd
    Linke, Berend
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (02) : 113 - 120