Deep learning strategies for critical heat flux detection in pool boiling

被引:44
作者
Rassoulinejad-Mousavi, Seyed Moein [1 ]
Al-Hindawi, Firas [2 ,3 ]
Soori, Tejaswi [1 ]
Rokoni, Arif [1 ]
Yoon, Hyunsoo [4 ]
Hu, Han [5 ]
Wu, Teresa [2 ,3 ]
Sun, Ying [1 ]
机构
[1] Drexel Univ, Dept Mech Engn & Mech, Philadelphia, PA 19104 USA
[2] Arizona State Univ, Sch Comp Informat & Decis Syst Engn, Tempe, AZ 85281 USA
[3] Arizona State Univ, ASU Mayo Ctr Innovat Imaging, Tempe, AZ 85281 USA
[4] SUNY Binghamton, Dept Syst Sci & Ind Engn, Binghamton, NY 13902 USA
[5] Univ Arkansas, Dept Mech Engn, Fayetteville, AR 72701 USA
基金
美国国家科学基金会;
关键词
Critical heat flux; Deep learning; Transfer learning; Convolutional neural network; Pool boiling; CONVOLUTIONAL NEURAL-NETWORKS; PREDICTION; CLASSIFICATION; FLOW; CANCER; MODEL; CHF;
D O I
10.1016/j.applthermaleng.2021.116849
中图分类号
O414.1 [热力学];
学科分类号
摘要
Image-based deep learning (DL) models are employed to enable the detection of critical heat flux (CHF) based on pool boiling experimental images. Most machine learning approaches for pool boiling to date focus on a single dataset under a certain heater surface, working fluid, and operating conditions. For new datasets collected under different conditions, a significant effort in re-training the model or developing a new model is required under the assumption the new dataset has a sufficient amount of data. This research is to explore strategies of DL adapting to new datasets with limited data available. The insights gained could help improve the practicality and reliability of DL for boiling regime studies. Specifically, convolutional neural networks (CNN) and transfer learning (TL) are studied. Using a base model trained and tested for one public dataset (DS1), CNN and TL models are trained with a small portion of a new public dataset (DS2) and tested for the rest of DS2. Results show that TL outperforms CNN by having much higher accuracy and a much lower false negative rate for scarce data (less than5% DS2). When 1% DS2 is used for re-training in CNN versus fine-tuning in TL, the TL model can detect the CHF with an accuracy of 94.79% and a false negative rate of 0.0997, compared with the CNN model with an accuracy of 85.10% and a false negative rate of 0.3237. To further demonstrate the advantage of TL over CNN, an in-house dataset (DS3) is acquired. With less than 0.05% DS3 being used, the TL model can detect the CHF with an accuracy of 95.31% and a false negative rate of 0.0016, compared with the CNN model with an accuracy of 85.91% and a false negative rate of 0.1263. It is observed that TL has much higher robustness than CNN by having more consistent results and smaller standard deviations over multiple trials using stratified random sampling from both DS2 and DS3. Besides, the training time for TL is significantly lower than CNN when limited data used in the re-training and fine-tuning for both DS2 and DS3. These results demonstrate the ability of TL for handling data scarcity in pool boiling applications with potentials for real-time implementations.
引用
收藏
页数:11
相关论文
共 66 条
[31]   Machine learning classification of boiling regimes with low speed, direct and indirect visualization [J].
Hobold, Gustavo M. ;
da Silva, Alexandre K. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 :1296-1309
[32]   A coupled wicking and evaporation model for prediction of pool boiling critical heat flux on structured surfaces [J].
Hu, Han ;
Weibel, Justin A. ;
Garimella, Suresh, V .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 136 :373-382
[33]   Digital mammographic tumor classification using transfer learning from deep convolutional neural networks [J].
Huynh, Benjamin Q. ;
Li, Hui ;
Giger, Maryellen L. .
JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
[34]   Real-Time Motor Fault Detection by 1-D Convolutional Neural Networks [J].
Ince, Turker ;
Kiranyaz, Serkan ;
Eren, Levent ;
Askar, Murat ;
Gabbouj, Moncef .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (11) :7067-7075
[35]  
Jun S, 2020, NUCL ENG TECHNOL, V52, P1939
[36]   Effect of heater orientation on pool boiling heat transfer from sintered copper microporous coating in saturated water [J].
Jun, Seongchul ;
Kim, Jinsub ;
You, Seung M. ;
Kim, Hwan Yeol .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 103 :277-284
[37]   Enhancement of Pool Boiling Heat Transfer in Water Using Sintered Copper Microporous Coatings [J].
Jun, Seongchul ;
Kim, Jinsub ;
Son, Donggun ;
Kim, Hwan Yeol ;
You, Seung M. .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2016, 48 (04) :932-940
[38]   Pool Boiling Heat Transfer Enhancement of Water Using Brazed Copper Microporous Coatings [J].
Jun, Seongchul ;
Wi, Hyoseong ;
Gurung, Ajay ;
Amaya, Miguel ;
You, Seung M. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2016, 138 (07)
[39]   Review and Projections of Integrated Cooling Systems for Three-Dimensional Integrated Circuits [J].
Kandlikar, Satish G. .
JOURNAL OF ELECTRONIC PACKAGING, 2014, 136 (02)
[40]   A theoretical model to predict pool boiling CHF incorporating effects of contact angle and orientation [J].
Kandlikar, SG .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2001, 123 (06) :1071-1079