TTC-Pluronic 3D radiochromic gel dosimetry of ionizing radiation

被引:39
|
作者
Kozicki, Marek [1 ,2 ]
Kwiatos, Klaudia [1 ]
Kadlubowski, Slawomir [3 ]
Dudek, Mariusz [4 ]
机构
[1] Lodz Univ Technol, Dept Man Made Fibres, Lodz, Poland
[2] GeVero Co, Lodz, Poland
[3] Lodz Univ Technol, Inst Appl Radiat Chem, Lodz, Poland
[4] Lodz Univ Technol, Inst Mat Sci & Engn, Lodz, Poland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 14期
关键词
2; 3; 5-triphenyltetrazolium chloride; Pluronic; 3D radiochromic gel; 3D dosimetry; radiotherapy dosimetry; ionising radiation; leucomalachite green; NITRO BLUE TETRAZOLIUM; HIGH-DOSE DOSIMETRY; POLYMER GELS; AQUEOUS-SOLUTIONS; COMPUTED-TOMOGRAPHY; HYDRATED ELECTRONS; HYDROXYL RADICALS; PULSE-RADIOLYSIS; ACTIVE COMPOUND; OPTICAL SCANNER;
D O I
10.1088/1361-6560/aa77eb
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work reports the first results obtained using a new 3D radiochromic gel dosimeter. The dosimeter is an aqueous physical gel matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127, PEO-PPO-PEO) doped with a representative of tetrazolium salts, 2, 3, 5-triphenyltetrazolium chloride (TTC). There were several reasons for the choice of Pluronic as a gel forming substrate: (i) the high degree of transparency and colourlessness; (ii) the possibility of gel dosimeter preparation at both high and low temperatures due to the phase behaviour of Pluronic; (iii) the broad temperature range over which the TTC-Pluronic dosimeter is stable; and (iv) the non-toxicity of Pluronic. A reason for the choice of TTC was its ionising radiation-induced transformation to water-insoluble formazan, which was assumed to impact beneficially on the spatial stability of the dose distribution. If irradiated, the TTC-Pluronic gels become red but transparent in the irradiated part, while the non-irradiated part remains crystal clear. The best obtained composition is characterised by <4 Gy dose threshold, a dose sensitivity of 0.00231 (Gy x cm)(-1), a large linear dose range of >500 Gy and a dynamic dose response much greater than 500 Gy (7.5% TTC, 25% Pluronic F-127, 50 mmol dm(-3) tetrakis). Temporal and spatial stability studies revealed that the TTC-Pluronic gels (7.5% TTC, 25% Pluronic F-127) were stable for more than one week. The addition of compounds boosting the gels' dose performance caused deterioration of the gels' temporal stability but did not impact the stability of the 3D dose distribution. The proposed method of preparation allows for the repeatable manufacture of the gels. There were no differences observed between gels irradiated fractionally and non-fractionally. The TTC-Pluronic dose response might be affected by the radiation source dose rate-this, however, requires further examination.
引用
收藏
页码:5668 / 5690
页数:23
相关论文
共 50 条
  • [21] Fast kinetics change of radiochromic film in point-based ionizing radiation dosimetry system
    Rink, A
    Vitkin, A
    Jaffray, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1839 - 1839
  • [22] A Radio-Fluorogenic Organic Gel for Real-Time, 3D Radiation Dosimetry
    Warman, John M.
    de Haas, Matthijs P.
    Luthjens, Leonard H.
    Murrer, Lars H. P.
    ADVANCED MATERIALS, 2011, 23 (42) : 4953 - 4955
  • [23] State of the art in 3D gel dosimetry for high-precision radiation treatment verifications
    De Deene, Y
    Vergote, K
    De Wagter, C
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S21 - S21
  • [24] 3D dose distribution measurements in brachytherapy using radiochromic gel dosimeters
    Solc, J.
    Sochor, V.
    Kacur, M.
    Smoldasova, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 163 - 166
  • [25] Clinical 3D Dosimetry in Modern Radiation Therapy
    Mihailidis, Dimitris
    MEDICAL PHYSICS, 2020, 47 (01) : 290 - 291
  • [26] 3D gel Dosimetry of IMSRT using normoxic MAGAT polymer gel
    Beiki-Ardakani, A
    Heydarian, M
    Vitkin, A
    Kirilova, A
    Princess, DJA
    MEDICAL PHYSICS, 2005, 32 (06) : 1978 - 1979
  • [27] Investigation of 3D gram materials for radiation dosimetry
    Readshaw, AK
    Brown, GO
    Phillips, GW
    Weiss, RG
    Guardala, NA
    Price, JL
    Mueller, SC
    Moscovitch, M
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 451 - 454
  • [28] Optical Scanner for 3D Radiotherapy Polymer Gel Dosimetry
    Sobotka, P.
    Kozicki, M.
    Maras, P.
    Boniecki, L.
    Kacperski, K.
    Domanski, A. W.
    ACTA PHYSICA POLONICA A, 2012, 122 (05) : 969 - 974
  • [29] On the chemical stability of 3D monomer/polymer gel dosimetry
    De Deene, Y
    De Wagter, C
    Achten, E
    De Neve, W
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 380 - 382
  • [30] Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry
    Krstajic, Nikola
    Doran, Simon J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (08): : 2055 - 2075