A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: Proof of concept

被引:68
|
作者
Hyer, Daniel E. [1 ]
Hill, Patrick M. [1 ]
Wang, Dongxu [1 ]
Smith, Blake R. [1 ]
Flynn, Ryan T. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
关键词
intensity modulated proton therapy (IMPT); spot scanning; protons; penumbra; collimation; RADIOTHERAPY; BEAM;
D O I
10.1118/1.4837155
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the absence of a collimation system the lateral penumbra of spot scanning (SS) dose distributions delivered by low energy proton beams is highly dependent on the spot size. For current commercial equipment, spot size increases with decreasing proton energy thereby reducing the benefit of the SS technique. This paper presents a dynamic collimation system (DCS) for sharpening the lateral penumbra of proton therapy dose distributions delivered by SS. Methods: The collimation system presented here exploits the property that a proton pencil beam used for SS requires collimation only when it is near the target edge, enabling the use of trimmers that are in motion at times when the pencil beam is away from the target edge. The device consists of two pairs of parallel nickel trimmer blades of 2 cm thickness and dimensions of 2 cm x 18 cm in the beam's eye view. The two pairs of trimmer blades are rotated 90 degrees relative to each other to form a rectangular shape. Each trimmer blade is capable of rapid motion in the direction perpendicular to the central beam axis by means of a linear motor, with maximum velocity and acceleration of 2.5 m/s and 19.6m/s(2), respectively. The blades travel on curved tracks to match the divergence of the proton source. An algorithm for selecting blade positions is developed to minimize the dose delivered outside of the target, and treatment plans are created both with and without the DCS. Results: The snout of the DCS has outer dimensions of 22.6 x 22.6 cm(2) and is capable of delivering a minimum treatment field size of 15 x 15 cm(2). Using currently available components, the constructed system would weigh less than 20 kg. For irregularly shaped fields, the use of the DCS reduces the mean dose outside of a 2D target of 46.6 cm(2) by approximately 40% as compared to an identical plan without collimation. The use of the DCS increased treatment time by 1-3 s per energy layer. Conclusions: The spread of the lateral penumbra of low-energy SS proton treatments may be greatly reduced with the use of this system at the cost of only a small penalty in delivery time. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Protonentherapie mit „Spot-Scanning“ bei Rhabdomyosarkomen im frühen KindesalterErste Erfahrungen am PSI“Spot-Scanning” Proton Therapy for Rhabdomyosarcomas of Early Childhood. First Experiences at PSI
    Beate Timmermann
    Andreas Schuck
    Felix Niggli
    Markus Weiss
    Anthony Lomax
    Gudrun Goitein
    Strahlentherapie und Onkologie, 2006, 182 : 653 - 659
  • [22] An analytical model for the upper bound estimation of respiratory motion-induced dose uncertainty in spot-scanning proton beam therapy
    Li, Heng
    Zhang, Xiaodong
    Li, Yupeng
    Zhu, Ronald X.
    MEDICAL PHYSICS, 2019, 46 (11) : 5249 - 5261
  • [23] Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment
    Smith, Blake
    Gelover, Edgar
    Moignier, Alexandra
    Wang, Dongxu
    Flynn, Ryan T.
    Lin, Liyong
    Kirk, Maura
    Solberg, Tim
    Hyer, Daniel E.
    MEDICAL PHYSICS, 2016, 43 (08) : 4693 - 4699
  • [24] Validation of Beam Accuracy of a Gated Spot-Scanning Proton Therapy System with Real-Time Tumor-Tracking at Hokkaido University
    Yamada, T.
    Matsuura, T.
    Toramatsu, C.
    Takao, S.
    Nihongi, H.
    Miyamoto, N.
    Shimizu, S.
    Takayanagi, T.
    Umezawa, M.
    Matsuda, K.
    Umegaki, K.
    Shirato, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 304 - +
  • [25] Results of spot-scanning proton radiation therapy for chordoma and chondrosarcoma of the skull base: The Paul Scherrer Institut experience
    Weber, DC
    Rutz, HP
    Pedroni, ES
    Bolsi, A
    Timmermann, B
    Verwey, J
    Lomax, AJ
    Goitein, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : 401 - 409
  • [26] Feasibility study: spot-scanning proton arc therapy (SPArc) for left-sided whole breast radiotherapy
    Sheng Chang
    Gang Liu
    Lewei Zhao
    Joshua T. Dilworth
    Weili Zheng
    Saada Jawad
    Di Yan
    Peter Chen
    Craig Stevens
    Peyman Kabolizadeh
    Xiaoqiang Li
    Xuanfeng Ding
    Radiation Oncology, 15
  • [27] A method to select aperture margin in collimated spot scanning proton therapy
    Wang, Dongxu
    Smith, Blake R.
    Gelover, Edgar
    Flynn, Ryan T.
    Hyer, Daniel E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07) : N109 - N119
  • [28] A linear relationship for the LET-dependence of Gafchromic EBT3 film in spot-scanning proton therapy
    Anderson, Sarah E.
    Grams, Michael P.
    Tseung, H. Wan Chan
    Furutani, Keith M.
    Beltran, Chris J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (05)
  • [29] Feasibility study: spot-scanning proton arc therapy (SPArc) for left-sided whole breast radiotherapy
    Chang, Sheng
    Liu, Gang
    Zhao, Lewei
    Dilworth, Joshua T.
    Zheng, Weili
    Jawad, Saada
    Yan, Di
    Chen, Peter
    Stevens, Craig
    Kabolizadeh, Peyman
    Li, Xiaoqiang
    Ding, Xuanfeng
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [30] Quality of Life and Toxicity From Passively Scattered and Spot-Scanning Proton Beam Therapy for Localized Prostate Cancer
    Pugh, Thomas J.
    Munsell, Mark F.
    Choi, Seungtaek
    Quyhn Nhu Nguyen
    Mathai, Benson
    Zhu, X. Ron
    Sahoo, Narayan
    Gillin, Michael
    Johnson, Jennifer L.
    Amos, Richard A.
    Dong, Lei
    Mahmood, Usama
    Kuban, Deborah A.
    Frank, Steven J.
    Hoffman, Karen E.
    McGuire, Sean E.
    Lee, Andrew K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (05): : 946 - 953