Strength of Pulvertaft modifications: tensile testing of porcine flexor tendons

被引:12
|
作者
Strandenes, Eivind [1 ]
Ellison, Peter [2 ,3 ]
Molster, Anders [3 ,5 ]
Gjerdet, Nils R. [4 ]
Moldestad, Irene O. [3 ]
Hol, Paul J. [3 ,5 ]
机构
[1] Haukeland Hosp, Plast Hand & Reconstruct Dept, Bergen, Norway
[2] Imperial Coll London, Dept Mech Engn, London, England
[3] Haukeland Hosp, Biomatlab, Bergen, Norway
[4] Univ Bergen, Dept Clin Dent, Bergen, Norway
[5] Univ Bergen, Dept Clin Med, Bergen, Norway
关键词
Pulvertaft weave; tendon transfer; biomechanics; tendons; tensile strength; MODIFIED KESSLER; WEAVE; REPAIR; SUTURE; GRAFTS;
D O I
10.1177/1753193419841522
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of the study was to present two new modifications of the Pulvertaft weave, allowing a higher number of weaves without the need for a longer overlap. The mechanical properties were measured and compared with the traditional technique. Forty-five pairs of porcine flexor tendons were randomized to a Pulvertaft repair with three weaves, a Double Pulvertaft and Locking Pulvertaft repairs. In the last two repairs one of the tendons in each repair was split in two before weaving. A difference in the maximum stiffness was observed between the three groups (p = 0.024). All repairs failed by the sutures being sheared through the tendons splitting the tendon fibres longitudinally. The two modifications were both stronger than the Pulvertaft weave and provide an alternative when a strong connection is needed and a longer overlap is impossible.
引用
收藏
页码:795 / 799
页数:5
相关论文
共 50 条
  • [1] Strength of side-to-side and step-cut repairs in tendon transfers: biomechanical testing of porcine flexor tendons
    Strandenes, Eivind
    Ellison, Peter
    Molster, Anders O.
    Gjerdet, Nils R.
    Moldestad, Irene O.
    Hol, Paul J.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (10) : 1061 - 1065
  • [2] Tensile strength of a weave tendon suture using tendons of different sizes
    Mazurek, Tomasz
    Strankowski, Michal
    Ceynowa, Marcin
    Roclawski, Marek
    CLINICAL BIOMECHANICS, 2011, 26 (04) : 415 - 418
  • [3] Evaluation of Suture Elongation of Flexor Tendons using the Pulvertaft Method: a Biomechanical Study using Cadaveric Specimens
    Ozone, E.
    Matsuura, Y.
    Suzuki, T.
    Kuniyoshi, K.
    Ohtori, S.
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2022, 12 (02): : 241 - 246
  • [4] INFLUENCE OF CORE SUTURE GEOMETRY ON TENDON DEFORMATION AND GAP FORMATION IN PORCINE FLEXOR TENDONS
    Walbeehm, E. T.
    De Wit, T.
    Hovius, S. E. R.
    Mcgrouther, D. A.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (02) : 190 - 195
  • [5] The influence of cross-sectional area on the tensile properties of flexor tendons
    Boyer, MI
    Meunier, MJ
    Lescheid, J
    Burns, ME
    Gelberman, RH
    Silva, MJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (05): : 828 - 832
  • [6] Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies?
    C. Domnick
    B. Wieskötter
    M. J. Raschke
    M. Schulze
    D. Kronenberg
    M. Wefelmeier
    M. F. Langer
    M. Herbort
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1465 - 1471
  • [7] Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies?
    Domnick, C.
    Wieskoetter, B.
    Raschke, M. J.
    Schulze, M.
    Kronenberg, D.
    Wefelmeier, M.
    Langer, M. F.
    Herbort, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (10) : 1465 - 1471
  • [8] An Analysis of the Pull-Out Strength of 6 Suture Loop Configurations in Flexor Tendons
    Karjalainen, T.
    He, M.
    Chong, A. K. S.
    Lim, A. Y. T.
    Ryhanen, J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (02): : 217 - 223
  • [9] A Nitinol Based Flexor Tendon Fixation Device: Gapping and Tensile Strength Measurements in Cadaver Flexor Tendon
    Reese, Shawn P.
    Kubiak, Erik N.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (01):
  • [10] The effects of freezing on the tensile properties of repaired porcine flexor tendon
    Hirpara, Kieran M.
    Sullivan, Paulj.
    O'Sullivan, Michael E.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (03): : 353 - 358