High-Energy Electron Scattering in Thick Samples Evaluated by Bright-Field Transmission Electron Microscopy, Energy-Filtering Transmission Electron Microscopy, and Electron Tomography

被引:11
|
作者
Hayashida, Misa [1 ]
Malac, Marek [1 ,2 ]
机构
[1] CNR, Nanotechnol Res Ctr, Edmonton, AB T6G 2M9, Canada
[2] Univ Alberta, Dept Phys, Edmonton, AB T6G 2E1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Beer-Lambert law; bright-field TEM; electron energy-loss spectroscopy (EELS); energy-filtering TEM; multiple scattering; thick sample; thickness measurement; transmission electron microscopy (TEM); MULTIPLE-SCATTERING; SPATIAL-RESOLUTION; CONTRAST; TEM; FILMS; DISSIPATION; PENETRATION; ATTENUATION; SPECIMEN;
D O I
10.1017/S1431927622000472
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Energy-filtering transmission electron microscopy (TEM) and bright-field TEM can be used to extract local sample thickness t and to generate two-dimensional sample thickness maps. Electron tomography can be used to accurately verify the local t. The relations of log-ratio of zero-loss filtered energy-filtering TEM beam intensity (I-Z(LP)) and unfiltered beam intensity (I-u) versus sample thickness t were measured for five values of collection angle in a microscope equipped with an energy filter. Furthermore, log-ratio of the incident (primary) beam intensity (I-p) and the transmitted beam I-tr versus t in bright-field TEM was measured utilizing a camera before the energy filter. The measurements were performed on a multilayer sample containing eight materials and thickness t up to 800 nm. Local thickness t was verified by electron tomography. The following results are reported: The maximum thickness t(max) yielding a linear relation of log-ratio, ln (I-u /I-ZLP) and ln (I-p/I-tr), versus t. Inelastic mean free path (lambda(in)) for five values of collection angle. Total mean free path (lambda(total))of electrons excluded by an angle-limiting aperture. lambda(in) and lambda(total) are evaluated for the eight materials with atomic number from approximate to 10 to 79. The results can be utilized as a guide for upper limit of t evaluation in energy-filtering TEM and bright-field TEM and for optimizing electron tomography experiments.
引用
收藏
页码:659 / 671
页数:13
相关论文
共 50 条
  • [1] Plasmon energy mapping in energy-filtering transmission electron microscopy
    Sigle, W
    Krämer, S
    Varshney, V
    Zern, A
    Eigenthaler, U
    Rühle, M
    ULTRAMICROSCOPY, 2003, 96 (3-4) : 565 - 571
  • [2] Quantitative energy-filtering transmission electron microscopy (EFTEM)
    Hofer, F
    Grogger, W
    Warbichler, P
    Papst, I
    MIKROCHIMICA ACTA, 2000, 132 (2-4) : 273 - 288
  • [3] Imaging of thick sections of nervous tissue with energy-filtering transmission electron microscopy
    Kortje, KH
    Paulus, U
    Ibsch, M
    Rahmann, H
    JOURNAL OF MICROSCOPY-OXFORD, 1996, 183 : 89 - 101
  • [4] Quantitative comparison of energy-filtering transmission electron microscopy and atom probe tomography
    Stender, Patrick
    Heil, Tobias
    Kohl, Helmut
    Schmitz, Guido
    ULTRAMICROSCOPY, 2009, 109 (05) : 612 - 618
  • [5] Energy-filtering transmission electron microscopy on the nanometer length scale
    Grogger, W
    Varela, M
    Ristau, R
    Schaffer, B
    Hofer, F
    Krishnan, KM
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2005, 143 (2-3) : 139 - 147
  • [6] Energy-filtering transmission electron microscopy for the characterization of polymer blend morphologies
    Horiuchi, S
    Yase, K
    Kitano, T
    Higashida, N
    Ougizawa, T
    POLYMER JOURNAL, 1997, 29 (04) : 380 - 383
  • [7] Energy-Filtering Transmission Electron Microscopy for the Characterization of Polymer Blend Morphologies
    Shin Horiuchi
    Kiyoshi Yase
    Takeshi Kitano
    Noboru Higashida
    Toshiaki Ougizawa
    Polymer Journal, 1997, 29 : 380 - 383
  • [8] Energy-filtering transmission electron microscopy (EFTEM) in the elemental analysis of pseudoexfoliative material
    Schlötzer-Schrehardt, U
    Kortje, KH
    Erb, C
    CURRENT EYE RESEARCH, 2001, 22 (02) : 154 - 162
  • [9] Direct visualization of intracellular calcium in rat osteoblasts by energy-filtering transmission electron microscopy
    Christian Bordat
    Jean-Luc Guerquin-Kern
    Michèle Lieberherr
    Giulia Cournot
    Histochemistry and Cell Biology, 2004, 121 : 31 - 38
  • [10] Direct visualization of intracellular calcium in rat osteoblasts by energy-filtering transmission electron microscopy
    Bordat, C
    Guerquin-Kern, JL
    Lieberherr, M
    Cournot, G
    HISTOCHEMISTRY AND CELL BIOLOGY, 2004, 121 (01) : 31 - 38