A Coordination Scheme of FACTS-Based WADC to Improve Small Signal Stability with Transient Stability Constraints in Multi-machine System

被引:0
|
作者
Pan, Mingsen [1 ]
Lin, Tao [1 ]
Ding, Guili [1 ]
Ding, Shaoqian [1 ]
Chen, Rusi [1 ]
Xu, Xialing [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Cent China Elect Power Dispatching & Commun Ctr, Wuhan, Peoples R China
关键词
ETA; MA; FACTS; WADC; Coordination Scheme;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the advent of smart-grid technology, the wide application of FACTS (Flexible AC Transmission Systems)based damping controllers exerts influences on both small signal stability and transient stability. Traditional Modal Analysis (MA) method can hardly meet the requirements of online applications. According to the inter-area oscillation mode to be studied, the multi-machine system can be equivalent to a two-machine system, and the Wide-Area Measurement System (WAMS) supports real-time dynamic equivalents. This paper explores the electric torque analysis (ETA) method in the two-machine system and the criteria of stability. An online coordination scheme of SVC-based Wide-Area Damping Controller (WADC) to maximize the damping ratio of the interarea mode with the transient stability constraints is presented in this paper. The scheme is treated as an optimization issue and a plant growth simulation algorithm (PGSA) is employed to search for the optimal controller parameters. A 4-machine-2-area benchmark is used to verify the effectiveness and advantages of the proposed scheme for online applications.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] A didactic procedure for transient stability simulation of a multi-machine power system utilizing SIMULINK
    Ekinci, Serdar
    Zeynelgil, H. Lale
    Demiroren, Aysen
    INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 2016, 53 (01) : 54 - 71
  • [42] Transient Stability Enhancement of Multi-Machine Power System by Novel Braking Resistor Models
    Saluja, Riya
    Ghosh, Sagnika
    Ali, Mohd. Hasan
    2013 PROCEEDINGS OF IEEE SOUTHEASTCON, 2013,
  • [43] MULTI-MACHINE POWER SYSTEM STABILIZER OPTIMIZATION BY MAXIMIZATION OF THE TRANSIENT STABILITY DOMAIN.
    Nourmoussavi, M.A.
    Crevier, D.
    1979,
  • [44] STABILITY OF A MULTI-MACHINE SYSTEM INCORPORATING A SUPERCONDUCTING ALTERNATOR
    RAHIM, YHA
    OSHEBA, SM
    ALYAN, MAAS
    ALOHALY, AA
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1988, 3 (03) : 458 - 464
  • [45] A coordinated strategy for multi-machine power system stability
    Ghasemi-Marzbali, Ali
    Ahmadiahangar, Roya
    Applied Soft Computing, 2021, 110
  • [46] A coordinated strategy for multi-machine power system stability
    Ghasemi-Marzbali, Ali
    Ahmadiahangar, Roya
    APPLIED SOFT COMPUTING, 2021, 110
  • [47] Transient Stability Assessment of Multi-Machine Multi-Converter Power Systems
    Pico, Hugo N. Villegas
    Johnson, Brian B.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (05) : 3504 - 3514
  • [48] Design of a robust UPFC controller for enhancing the small signal stability in the multi-machine power systems
    Seo, JC
    Moon, SI
    Park, JK
    Choe, JW
    2001 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-3, 2001, : 1197 - 1202
  • [49] Selection of robust installing locations and feedback signals of FACTS-based stabilizers in multi-machine power systems
    Wang, HF
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1999, 14 (02) : 569 - 574
  • [50] Evaluating the robustness of FACTS-based stabilizers and PSSS by damping torque analysis in multi-machine power systems
    Wang, Haifeng
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2002, 26 (SUPPL.): : 35 - 40