Experience and effectiveness of application of transmission line arresters

被引:0
|
作者
Shigeno, T
机构
关键词
overhead line; transmission line arrester; ZnO arrester; double-circuit trip -out; lightning;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Installation of transmission line arresters (hereinafter referred to as line arresters) in Japan started in 1980. Since then line arresters have been applied in service for more than 20 years as effective countermeasures against lightning attack This paper describes basic specifications of line arresters and effectiveness of application based on the recent datum.
引用
收藏
页码:636 / 639
页数:4
相关论文
共 50 条
  • [1] Transmission Line Arresters Application for Control of Switching Overvoltages on 500-kV Transmission Line
    Bunov, P.
    Klingbeil, L.
    Schubert, M.
    Gossler, B.
    Biswas, D.
    Hunt, James
    Thallam, R.
    Keri, A. J. F.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [2] Research on transmission line system simulation models with line arresters and its application
    Ren, Xiaona
    Wu, Guangning
    Fu, Longhai
    Li, Zeng
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 322 - +
  • [3] Application of line surge arresters to double-circuit transmission lines
    Institute of Industrial Science, University of Tokyo, Tokyo, Japan
    不详
    Int. Symp. Light. Prot., XI SIPDA, 2011, (312-318):
  • [4] Application of line surge arresters for voltage uprating and compacting of overhead transmission lines
    Filipovic-Grcic, Bozidar
    Uglesic, Ivo
    Pavic, Ivica
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 : 830 - 835
  • [5] A new application concept of transmission line arresters to 500-kV lines
    Yamamoto, Y
    Hanada, T
    Omote, T
    Nakura, T
    Hayashi, T
    Fujita, H
    Irie, T
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 681 - 686
  • [6] Energy handling considerations for transmission line arresters
    Woodworth, JJ
    Gravunder, J
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1085 - 1087
  • [7] On the Analysis and Evaluation of a Transmission Line Upgrading Assisted by Line Arresters
    Jardini, J. A.
    Missali, D.
    Jardini, M. G. M.
    Vasquez-Arnez, R. L.
    Masuda, M.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 2206 - +
  • [8] DESIGN OF ZINC OXIDE TRANSMISSION LINE ARRESTERS FOR APPLICATION ON 138 KV TOWERS.
    Koch, R.E.
    Timoshenko, J.A.
    Anderson, J.G.
    Shih, C.H.
    IEEE transactions on power apparatus and systems, 1985, PAS-104 (10): : 2675 - 2680
  • [9] Surge arresters' circuit models review and their application to a Hellenic 150 kV transmission line
    Christodoulou, C. A.
    Ekonomou, L.
    Mitropoulou, A. D.
    Vita, V.
    Stathopulos, I. A.
    SIMULATION MODELLING PRACTICE AND THEORY, 2010, 18 (06) : 836 - 849
  • [10] Design and application of line surge arresters to improve lightning protection characteristics of transmission lines
    He, Jin-Liang
    Zeng, Rong
    Hu, Jun
    Chen, Shui-Ming
    Zhao, Jie
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1562 - +