Influence of different design parameters on the seismic performance of partially grouted masonry shear walls

被引:20
作者
Calderon, Sebastian [1 ,2 ]
Sandoval, Cristian [1 ,3 ]
Araya-Letelier, Gerardo [4 ]
Inzunza, Ernesto [1 ]
Arnau, Oriol [5 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[3] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Civil Construct, Casilla 306,Correo 22, Santiago, Chile
[5] Iktes, Mexico City, DF, Mexico
关键词
Reinforced masonry; Partially-grouted masonry; In-plane testing; Shear response; Shear walls; BEHAVIOR;
D O I
10.1016/j.engstruct.2021.112058
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent earthquakes in Chile (e.g., Maule's 2010 earthquake), buildings built with bed-joint partially grouted reinforced masonry (BJ-PG-RM) shear walls made of multi-perforated clay bricks (MPCB) have not collapsed, although significant damages have been reported. Additionally, experimental data on the influence of the different design parameters that control its seismic behavior is scarce, and the available expressions for estimating their lateral resistance are inaccurate. To address these issues, nine full-scale BJ-PG-RM walls made of MPCB were tested under axial pre-compression and cyclic lateral loads. The study addressed the influence of the aspect (height-to-length) ratio, axial pre-compression, mortar compressive strength, mortar joints' thickness, bricks' height, and horizontal and vertical reinforcement ratio. The results were analyzed in terms of hysteretic response, damage evolution, seismic performance parameters (shear strength, equivalent viscous damping ratio, ductility, and lateral stiffness degradation). All designed walls failed in a diagonal tension failure mode. Besides, all studied variables influenced the stresses and crack patterns. Also, the shear strength increases when: (i) lower aspect ratio or joint thickness are used; and (ii) higher axial load ratio, horizontal reinforcement ratio, vertical reinforcement ratio, or mortar compressive strength are used. Moreover, when damage progresses, the lateral secant stiffness decays faster as a result of: (i) larger joint thickness or vertical reinforcement ratio; (ii) lower mortar compressive strength. Most walls exhibited an equivalent viscous damping ratio between 5% and 10% for an intermediate state of damage. However, the evaluated design parameters did not considerably affect the development of the viscous damping ratio as a function of the drift ratio. The displacement ductility of the walls ranged from 1.5 to 2.5, where the height of bricks and the vertical reinforcement ratio had positive effects, and the joint thickness, the mortar compressive strength, and the horizontal reinforcement ratio a negative effect. The lateral resistance of tested walls was also estimated with six expressions, but none of them provided accurate results.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Lateral cyclic performance of flexural-dominated partially grouted reinforced concrete masonry shear walls with bed joint reinforcement
    Abdallah, Abdelrahman
    Abdelrahman, Belal
    Galal, Khaled
    ENGINEERING STRUCTURES, 2025, 328
  • [32] Experimental cyclic response assessment of partially grouted reinforced clay brick masonry walls
    Sandoval, Cristian
    Calderon, Sebastian
    Luis Almazan, Jose
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (07) : 3127 - 3152
  • [33] Effect of reinforcement anchorage end detail and spacing on seismic performance of masonry shear walls
    ElDin, Hany M. Seif
    Galal, Khaled
    ENGINEERING STRUCTURES, 2018, 157 : 268 - 279
  • [34] Experimental Seismic Performance Evaluation of Unreinforced Brick Masonry Shear Walls
    Javed, Mohammed
    Magenes, Guido
    Alam, Bashir
    Khan, Akhtar Naeem
    Ali, Qaisar
    Syed, Ali M.
    EARTHQUAKE SPECTRA, 2015, 31 (01) : 215 - 246
  • [35] Effect of boundary element detailing on the seismic performance of reinforced concrete masonry shear walls
    Albutainy, Mohammed
    Galal, Khaled
    ENGINEERING STRUCTURES, 2024, 300
  • [36] Experimental study on the seismic performance of concrete shear walls partially replaced by MRPC
    Yang, Jian
    Li, Ling-Zhi
    Wang, Xin
    Hu, Sheng-Xing
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [37] Seismic performance of mortarless reinforced masonry walls
    Huang, Liang
    Lu, Yiqiu
    Yan, Libo
    Kasal, Bohumil
    Wang, Lu
    Zhang, Tongyue
    JOURNAL OF BUILDING ENGINEERING, 2020, 31 (31)
  • [38] Performance of partially grouted reinforced masonry walls with bed-joint reinforcement: parametric and optimization investigation
    Faridmehr, Iman
    Nehdi, Moncef L.
    Farokhi Nejad, Ali
    Valerievich, Kiyanets Aleksandr
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2023, 24 (01)
  • [39] Seismic Performance Investigation of different kinds of Shear Walls
    Zhang, Pinle
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 1615 - 1618
  • [40] Experimental and Numerical Study on the Seismic Performance of Prefabricated Reinforced Masonry Shear Walls
    Xu, Weifan
    Yang, Xu
    Wang, Fenglai
    Chi, Bin
    APPLIED SCIENCES-BASEL, 2018, 8 (10):