Influence of different design parameters on the seismic performance of partially grouted masonry shear walls

被引:20
|
作者
Calderon, Sebastian [1 ,2 ]
Sandoval, Cristian [1 ,3 ]
Araya-Letelier, Gerardo [4 ]
Inzunza, Ernesto [1 ]
Arnau, Oriol [5 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[3] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Civil Construct, Casilla 306,Correo 22, Santiago, Chile
[5] Iktes, Mexico City, DF, Mexico
关键词
Reinforced masonry; Partially-grouted masonry; In-plane testing; Shear response; Shear walls; BEHAVIOR;
D O I
10.1016/j.engstruct.2021.112058
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent earthquakes in Chile (e.g., Maule's 2010 earthquake), buildings built with bed-joint partially grouted reinforced masonry (BJ-PG-RM) shear walls made of multi-perforated clay bricks (MPCB) have not collapsed, although significant damages have been reported. Additionally, experimental data on the influence of the different design parameters that control its seismic behavior is scarce, and the available expressions for estimating their lateral resistance are inaccurate. To address these issues, nine full-scale BJ-PG-RM walls made of MPCB were tested under axial pre-compression and cyclic lateral loads. The study addressed the influence of the aspect (height-to-length) ratio, axial pre-compression, mortar compressive strength, mortar joints' thickness, bricks' height, and horizontal and vertical reinforcement ratio. The results were analyzed in terms of hysteretic response, damage evolution, seismic performance parameters (shear strength, equivalent viscous damping ratio, ductility, and lateral stiffness degradation). All designed walls failed in a diagonal tension failure mode. Besides, all studied variables influenced the stresses and crack patterns. Also, the shear strength increases when: (i) lower aspect ratio or joint thickness are used; and (ii) higher axial load ratio, horizontal reinforcement ratio, vertical reinforcement ratio, or mortar compressive strength are used. Moreover, when damage progresses, the lateral secant stiffness decays faster as a result of: (i) larger joint thickness or vertical reinforcement ratio; (ii) lower mortar compressive strength. Most walls exhibited an equivalent viscous damping ratio between 5% and 10% for an intermediate state of damage. However, the evaluated design parameters did not considerably affect the development of the viscous damping ratio as a function of the drift ratio. The displacement ductility of the walls ranged from 1.5 to 2.5, where the height of bricks and the vertical reinforcement ratio had positive effects, and the joint thickness, the mortar compressive strength, and the horizontal reinforcement ratio a negative effect. The lateral resistance of tested walls was also estimated with six expressions, but none of them provided accurate results.
引用
收藏
页数:23
相关论文
共 50 条
  • [11] Partially grouted masonry walls with different horizontal reinforcement types: North American-compliant experimental performance for low seismic risk areas
    Rahim, Amr Ba
    Pettit, Clayton
    Cruz-Noguez, Carlos
    Sandoval, Cristi an
    JOURNAL OF BUILDING ENGINEERING, 2023, 78
  • [12] Shear load capacity prediction of unperforated and perforated partially grouted masonry walls
    Medeiros, Klaus A. S.
    Parsekian, Guilherme A.
    Shrive, Nigel G.
    Fonseca, Fernando S.
    ENGINEERING STRUCTURES, 2022, 256
  • [13] Experimental and Analytical Study on the Shear-Strength of Partially Grouted Masonry Walls
    Elmapruk, Jamal
    ElGawady, Mohamed A.
    Hassanli, Reza
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (08)
  • [14] Fragility functions for partially-grouted masonry shear walls with bed-joint reinforcement
    Araya-Letelier, Gerardo
    Calderon, Sebastian
    Sandoval, Cristian
    Sanhueza, Matias
    Murcia-Delso, Juan
    ENGINEERING STRUCTURES, 2019, 191 : 206 - 218
  • [15] Seismic strengthening of partially grouted masonry walls with openings: Evaluation of ferrocement and BTRM solutions
    Perez-Pinedo, Luis
    Sandoval, Cristian
    Alvarado, Rolando
    Vargas, Laura
    Calderon, Sebastian
    Bernat, Ernest
    JOURNAL OF BUILDING ENGINEERING, 2024, 88
  • [16] New Design Detail to Enhance the Seismic Performance of Ordinary Reinforced Partially Grouted Masonry Structures
    Bolhassani, M.
    Hamid, A. A.
    Johnson, C.
    Moon, F. L.
    Schultz, Arturo E.
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (12)
  • [17] Seismic Performance Assessment of Partially Grouted, Nominally Reinforced Concrete- Masonry Structural Walls Using Shake Table Testing
    Kasparik, Tomas
    Tait, Michael J.
    El-Dakhakhni, Wael W.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2014, 28 (02) : 216 - 227
  • [18] Experimental study on in-plane cyclic response of partially grouted reinforced concrete masonry shear walls
    Ramirez, Pablo
    Sandoval, Cristian
    Luis Almazan, Jose
    ENGINEERING STRUCTURES, 2016, 126 : 598 - 617
  • [19] Empirical drift capacity models for fully grouted reinforced masonry shear walls
    Ghaseminia, Seyed Meghdad
    Zahra, Tatheer
    Derakhshan, Hossein
    Thamboo, Julian
    Thambiratnam, David P.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2025, 23 (01) : 213 - 239
  • [20] In-plane cyclic performance of confined partially grouted masonry walls with joint and vertical reinforcement
    Hidalgo-Leiva, Diego A.
    Picado-Arguecas, Andres
    Sanchez-Vargas, Natalia
    ENGINEERING STRUCTURES, 2021, 245