Enhancing in vivo renal ischemia assessment by high-dynamic-range fluorescence molecular imaging

被引:1
|
作者
Gao, Yang [1 ]
Zhou, Yuan [1 ]
Liu, Fei [2 ]
Luo, Jianwen [1 ,3 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing, Peoples R China
[2] Beijing Jiaotong Univ, Sch Comp & Informat Technol, Beijing, Peoples R China
[3] Tsinghua Univ, Ctr Biomed Imaging Res, Beijing, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
fluorescence molecular imaging; high-dynamic-range; fluorophore distribution; renal ischemia assessment; GROWTH-FACTOR RECEPTOR; MULTIPARAMETRIC EVALUATION; LASER AUTOFLUORESCENCE; HINDLIMB ISCHEMIA; REPERFUSION; TOMOGRAPHY; TEMPERATURE; PATHWAYS; KIDNEYS; INJURY;
D O I
10.1117/1.JBO.23.7.076009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence imaging has been used to evaluate the physiological features of renal ischemia in animal model. However, the fluorophore distribution details of the ischemia model could not be fully represented due to the limited dynamic range of the charged-couple device. A high-dynamic-range (HDR) strategy was adopted in renal ischemia fluorescence imaging, both ex vivo and in vivo. The HDR strategy successfully combined ischemia relevant biological features that could only be captured with different exposure times, and then presented these features in the HDR results. The HDR results effectively highlighted the renal ischemic areas with relatively better perfusion and diminished the saturation that resulted from long exposure time. The relative fluorescence intensities of the ischemic kidneys and the image entropy values were significantly higher in the HDR images than in the original images, therefore enhancing the visualization of the renal ischemia model. The results suggest that HDR could serve as a postprocessing strategy to enhance the assessment of in vivo renal ischemia, and HDR fluorescence molecular imaging could be a valuable imaging tool for future studies of clinical ischemia detection and evaluation. (C) 2018 Society of Photo-Optical Instrumentation Engineers (SPIE).
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Ultra-sensitive optical coherence elastography using a high-dynamic-range force loading scheme for cervical rigidity assessment
    Yao, Xinwen
    Li, Dawei
    Park, Hyeon-Cheol
    Chen, Defu
    Guan, Honghua
    Mahendroo, Mala
    Li, Xingde
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (02) : 688 - 698
  • [32] Multi-Integration Time Adaptive Selection Method for Superframe High-Dynamic-Range Infrared Imaging Based on Grayscale Information
    Tao, Xingyu
    Jin, Weiqi
    Yang, Jianguo
    Li, Shuo
    Su, Binghua
    Wang, Minghe
    SENSORS, 2022, 22 (11)
  • [33] Detail enhancement for high-dynamic-range infrared images based on guided image filter
    Liu, Ning
    Zhao, Dongxue
    INFRARED PHYSICS & TECHNOLOGY, 2014, 67 : 138 - 147
  • [34] Facilitating in vivo tumor localization by principal component analysis based on dynamic fluorescence molecular imaging
    Gao, Yang
    Chen, Maomao
    Wu, Junyu
    Zhou, Yuan
    Cai, Chuangjian
    Wang, Daliang
    Luo, Jianwen
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (09)
  • [35] High-dynamic-range 3D shape measurement based on time domain superposition
    Zhang, Liang
    Chen, Qian
    Zuo, Chao
    Tao, Tianyang
    Zhang, Yuzhen
    Feng, Shijie
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (06)
  • [36] A 4MP high-dynamic-range, low-noise CMOS image sensor
    Ma Cheng
    Liu Yang
    Li Jing
    Zhou Quan
    Chang Yuchun
    Wang Xinyang
    IMAGE SENSORS AND IMAGING SYSTEMS 2015, 2015, 9403
  • [37] High-Dynamic-Range Absorption Spectroscopy by Generating a Wide Path-Length Distribution with Scatterers
    Mori, Ayaka
    Yamashita, Kyohei
    Tokunaga, Eiji
    PHOTONICS, 2024, 11 (06)
  • [38] Improved Threat Identification Using Tonemapping of High-Dynamic-Range X-ray Images
    Glover, Jack L.
    Hudson, Lawrence T.
    Paulter, Nicholas G.
    JOURNAL OF TESTING AND EVALUATION, 2018, 46 (04) : 1462 - 1467
  • [39] Everolimus-eluting stents stabilize plaque inflammation in vivo: assessment by intravascular fluorescence molecular imaging
    Press, Marcella A. Calfon
    Mallas, Georgios
    Rosenthal, Amir
    Hara, Tetsuya
    Mauskapf, Adam
    Nudelman, R. Nika
    Sheehy, Alexander
    Polyakov, Igor V.
    Kolodgie, Frank
    Virmani, Renu
    Guerrero, J. Luis
    Ntziachristos, Vasilis
    Jaffer, Farouc A.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (05) : 510 - 518
  • [40] Split Aperture Imaging for High Dynamic Range
    Manoj Aggarwal
    Narendra Ahuja
    International Journal of Computer Vision, 2004, 58 : 7 - 17