The Usage of CO2 Tracer Gas Methods for Ventilation Performance Evaluation in Apartment Buildings

被引:2
|
作者
Mikola, Alo [1 ]
Koiv, Teet-Andrus [1 ]
Rehand, Juhan [1 ]
Voll, Hendrik [1 ]
机构
[1] Tallinn Univ Technol, Dept Civil Engn & Architecture, Tallinn, Estonia
来源
10TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (10TH ICEE) | 2017年
关键词
Performance of ventilation; tracer gas methods; natural ventilation; metabolic CO2 method; AIR; RATES;
D O I
10.3846/enviro.2017.267
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of the study is to investigate the potential of the CO2-based tracer gas methods for the ventilation performance evaluation in apartment buildings. To test and elaborate the methods, the ventilation air change rate (ACR) and air change efficiency (ACE) measurements were performed. The methods were tested in laboratory conditions and apartments with natural ventilation, room-based ventilation units, exhaust ventilation and mechanical exhaust ventilation with fresh air radiators. Concentration decay method is applied with both artificially and naturally increasing the concentration of tracer gas. The ACR is also calculated using metabolic constant dosing method with the effective volume. As the traditional tracer gas methods give the correct result only in case of perfect mixed ventilation, then the ACE is also measured. To observe the effectiveness of the air change and the level of air mixing multiple CO2 sensors placed in different positions. The tracer gas measurements were carried out in naturally ventilated apartments to study the influence of the inner doors to the ACE. The daily variation of CO2 level in case the long-term CO2 measurements gives us the possibility to calculate the ACR when inhabitants are sleeping or have left the apartment. Using the CO2 as the natural tracer gas and the concentration decay method together with the metabolic constant dosing strategy, we can calculate the CO2 concentrations according to the long-term CO2 measurements without knowing the exact emission of inhabitants. The studied methods are inexpensive and at the same time sufficiently accurate for airflow measurements. Another reason for the study comes from the ventilation retrofit process in Estonia where the single room ventilation units are used. As these wall-mounted ventilation units are sensitive to in- and outside pressure differences the measurement of ventilation airflow in the traditional way can be inaccurate.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A comparison of tracer methods for quantifying CO2 sources in an urban region
    Djuricin, Sonja
    Pataki, Diane E.
    Xu, Xiaomei
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2010, 115
  • [22] A novel ventilation strategy with CO2 capture device and energy saving in buildings
    Kim, Moon Keun
    Baldini, Luca
    Leibundgut, Hansjuerg
    Wurzbacher, Jan Andre
    Piatkowski, Nic
    ENERGY AND BUILDINGS, 2015, 87 : 134 - 141
  • [23] Review of tracer gas-based methods for the characterization of natural ventilation performance: Comparative analysis of their accuracy
    Remion, Gabriel
    Moujalled, Bassam
    El Mankibi, Mohamed
    BUILDING AND ENVIRONMENT, 2019, 160
  • [24] Seismic performance evaluation of partially staggered-wall apartment buildings
    Kim, Jinkoo
    Jun, Yong
    MAGAZINE OF CONCRETE RESEARCH, 2011, 63 (12) : 927 - 939
  • [25] Performance Evaluation of Thermal Bridge Reduction Method for Balcony in Apartment Buildings
    Zhang, Xinwen
    Jung, Gun-Joo
    Rhee, Kyu-Nam
    BUILDINGS, 2022, 12 (01)
  • [26] Measurement of ventilation rate in livestock buildings with radioactive tracer gas technique: Theory and methodology
    Samer, M.
    Mueller, H. -J.
    Fiedler, M.
    Berg, W.
    Brunsch, R.
    INDOOR AND BUILT ENVIRONMENT, 2014, 23 (05) : 692 - 708
  • [27] DISTRIBUTION OF VENTILATION - CLINICAL EVALUATION BY RAPID CO2 ANALYSIS
    TULOU, PP
    DISEASES OF THE CHEST, 1966, 49 (02): : 139 - &
  • [28] Experimental study of ventilation performance of three ventilation strategies using aerosols and tracer gas
    Sanchez-Jimenez, J. L.
    de Adana, M. Ruiz
    RESULTS IN ENGINEERING, 2024, 24
  • [29] 2 METHODS OF GIVING INHALED CO2 AT CONSTANT INFLOW - EFFECTS ON VENTILATION
    CUMMIN, ARC
    JOURNAL OF PHYSIOLOGY-LONDON, 1984, 357 (DEC): : P135 - P135
  • [30] AIRBORNE CO2 DIAL MEASUREMENT OF ATMOSPHERIC TRACER GAS CONCENTRATION DISTRIBUTIONS
    UTHE, EE