Evaluation of the Accuracy of Digital Impressions Obtained from Intraoral and Extraoral Dental Scanners with Different CAD/CAM Scanning Technologies: An In Vitro Study

被引:21
作者
Ellakany, Passent [1 ]
El Tantawi, Maha [2 ]
Mahrous, Amr A. [1 ]
Al-Harbi, Fahad [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Substitut Dent Sci, POBox 1982, Dammam, Saudi Arabia
[2] Alexandria Univ, Fac Dent, Dept Pediat Dent & Dent Publ Hlth, Alexandria, Egypt
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2022年 / 31卷 / 04期
关键词
Computer-aided design; computer-aided manufacturing (CAD; CAM); intraoral scanner; extraoral scanner; digital impression; conventional impression; CONVENTIONAL IMPRESSIONS; PREPARED TEETH; REPRODUCIBILITY;
D O I
10.1111/jopr.13400
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare the accuracy of intraoral and extraoral scanners (IOSs and EOSs) with different scanning technologies. Material and Methods A phantom cast was used to simulate the patient's mouth. Polyether impression was made of the phantom cast and poured to fabricate stone casts. The stone casts were scanned by two IOSs (3shape Trios 3, 3S and Dental Wings, DW) and two EOSs (S600 Arti Zirkonzahn, ZK and Ceramill map 600 Amann Girrbach, AG) to obtain digital casts. Reference teeth (canines, premolar, and molars) dimensions were measured on the digital casts by Geomagic software and compared to measurements of the stone cast done by stereomicroscope. The dimensions were occluso-cervical mesio-distal, and bucco-lingual and their average was calculated. Differences between digital and stereoscopic measurements were assessed using paired t-test. Discrepancies between these measurements were calculated as differences and were compared among the four scanners using ANOVA. Results The differences among the discrepancies of the four scanners were not significant overall (p = 0.969), in premolars (p = 0.932) or molars (p = 0.069) but significant in canines (p = 0.025). The discrepancies of the EOSs were <= 0.01 mm in canines and molars. DW had the greatest discrepancy in canines and molars. Conclusions The IOSs and EOSs had similar accuracy except in canines where EOSs performed better. The accuracy of scanning is affected by the smoothness and regularity of the teeth surfaces as in case of the canine.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 33 条
  • [1] Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review
    Ahlholm, Pekka
    Sipila, Kirsi
    Vallittu, Pekka
    Jakonen, Minna
    Kotiranta, Ulla
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01): : 35 - 41
  • [2] Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial
    Ahrberg, Danush
    Lauer, Hans Christoph
    Ahrberg, Martin
    Weigl, Paul
    [J]. CLINICAL ORAL INVESTIGATIONS, 2016, 20 (02) : 291 - 300
  • [3] A New Method for Prediction of Dental Arch Perimeter
    Al-Ansari, Nadia Basim
    Ameer, Suha Ali Abdul
    Nahidh, Mohammed
    [J]. CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2019, 11 : 393 - 397
  • [4] Aly Passent, 2020, Eur J Dent, V14, P189, DOI 10.1055/s-0040-1705243
  • [5] Studying the Optical 3D Accuracy of Intraoral Scans: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    Peampring, Chaimongkon
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2020, 2020 (2020)
  • [6] In vitro evaluation of the accuracy and precision of intraoral and extraoral scans
    Baghani, Mohammad Taghi
    Shayegh, Sayed Shojaedin
    Johnston, William M.
    Shidfar, Shireen
    Hakimaneh, Seyed Mohammad Reza
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (05) : 665 - 670
  • [7] Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns
    Berrendero, S.
    Salido, M. P.
    Valverde, A.
    Ferreiroa, A.
    Pradies, G.
    [J]. Clinical Oral Investigations, 2016, 20 (09) : 2403 - 2410
  • [8] Comparison of an indirect impression scanning system and two direct intraoral scanning systems in vivo
    Bosniac, Patricia
    Rehmann, Peter
    Woestmann, Bernd
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (05) : 2421 - 2427
  • [9] Dahlberg G., 1940, Statistical Methods for Medical and Biological Students.
  • [10] Diker B, 2020, J ADV PROSTHODONT, V12, P299