Impedance interaction and EMI attenuation in converters with an integrated transmission-line filter

被引:5
|
作者
Baisden, Andrew C. [1 ]
Boroyevich, Dushan [1 ]
van Wyk, Jacobus Daniel [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Ctr Power Elect Syst, Bradley Dept Elect & Comp Engn, 665 Whittemore Hall 0179, Blacksburg, VA 24061 USA
基金
美国国家科学基金会;
关键词
transmission-line filter; electromagnetic interference (EMI); Powerfactor correction circuit (PFC);
D O I
10.1109/APEX.2007.357667
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
integrated transmission-line filters were previously proposed to attenuate conducted electro-magnetic interference (EMI) produced by high-frequency switching power converters. In this work, such a filter is manufactured using planar processing technologies, and it is tested for the first time with a 500W, front-end, single-phase power factor correction converter switching at 400 kHz. Impedance interactions between the filter, the converter, and the EMI measurement set-up are discussed, evaluated, measured, and improved to minimize undesired resonances and increase low-frequency EMI attenuation. Experimentally measured attenuation provided by the filter in the range from 100 kHz to 100 MHz was 20-50 dB.
引用
收藏
页码:1203 / +
页数:2
相关论文
共 50 条