Calibration of a passive rem counter with monoenergetic neutrons

被引:2
|
作者
Caresana, M. [1 ]
Ferrarini, M. [2 ]
Parravicini, A. [3 ]
Naik, A. Sashala [1 ,3 ]
机构
[1] Politecn Milan, Dipartimento Energia, I-20133 Milan, Italy
[2] CNAO Fdn, I-27100 Pavia, Italy
[3] Mi Am Srl, I-29029 Fabiano Di Rivergaro, PC, Italy
关键词
SSNTD; Neutron; Rem counter; Track detectors;
D O I
10.1016/j.radmeas.2014.07.019
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Rem-Counters are widely used in radiation protection practice for environmental neutron detection. They are usually based on both an active and a passive thermal neutron detector surrounded by a hydrogenate moderator designed to obtain a response function as close as possible to the H*(10) curve. Inclusion of high Z material is also used to extend the response function up to 1 GeV of neutron energy. Recently a dual detector Rem-Counter, both active and passive, was proposed by Agosteo et al. (2010). The present paper focuses on the passive version that is based on a CR-39 track detector coupled to an enriched B-10 converter. A technique was developed for the track analysis based on the measurement of the mean LET of the charged particles produced by the neutron reaction on B-10 that has proven to be very effective in the background reduction. Moreover the simulated response function of the Rem-Counter was compared with the experimental results obtained with irradiations carried out with monoenergetic neutron beams, showing a quite good agreement. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:498 / 501
页数:4
相关论文
共 50 条
  • [31] METHOD FOR PRODUCING MONOENERGETIC NEUTRONS AT KILOVOLT ENERGIES
    BINNEY, SE
    AMSTER, H
    HENNINGE.RJ
    MARK, H
    NUCLEAR INSTRUMENTS & METHODS, 1971, 97 (01): : 139 - &
  • [32] SCINTILLATION COUNTER FOR NEUTRONS
    SUN, KH
    SHOUPP, WE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1950, 21 (04): : 395 - 396
  • [33] A COUNTER FOR FAST NEUTRONS
    JASTRAM, PS
    BENADE, AH
    CLELAND, MR
    HUGHES, AL
    PHYSICAL REVIEW, 1951, 81 (02): : 327 - 327
  • [34] CALIBRATION OF THE NEUTRON REM COUNTER LINUS IN THE ENERGY-RANGE FROM THERMAL TO 19 MEV
    BIRATTARI, C
    ESPOSITO, A
    FERRARI, A
    PELLICCIONI, M
    SILARI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (1-2): : 232 - 238
  • [35] STUDIES ON THE PRODUCTION OF MONOENERGETIC NEUTRONS BY UNIFORM MODERATION OF D-T NEUTRONS
    BRADLEY, DA
    CHONG, CS
    GHOSE, AM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 270 (2-3): : 537 - 541
  • [36] NEUTRON REM COUNTER.
    Suzuki, Toshikazu
    Tsukino, Kazuo
    Yamano, Toshiya
    Yoshida, Yoshiteru
    1600,
  • [37] A REM METER FOR PULSED SOURCES OF NEUTRONS
    THORNGATE, JH
    HUNT, GF
    RUEPPEL, DW
    HEALTH PHYSICS, 1980, 39 (06): : 1064 - 1064
  • [38] THE RESPONSE OF THE ANTHRACENE SCINTILLATION COUNTER TO MONOENERGETIC ELECTRONS
    HOPKINS, JI
    PHYSICAL REVIEW, 1950, 77 (03): : 406 - 407
  • [39] ISOTROPIC AND CLOUD SOURCE IRRADIATION BY MONOENERGETIC NEUTRONS AND PHOTONS
    JONES, TD
    POSTON, JW
    HEALTH PHYSICS, 1978, 34 (01): : 83 - 95
  • [40] EXTRAPOLATION DISTANCE FOR MONOENERGETIC NEUTRONS IN SLABS . VARIATIONAL CALCULATIONS
    GOLDSCHMIDT, P
    NUKLEONIK, 1968, 10 (06): : 332 - +